BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

813 related articles for article (PubMed ID: 27865711)

  • 1. Use of an ePTFE-covered nitinol self-expanding stent graft for the treatment off pre-closure device failure during transcatheter aortic valve replacement.
    Steinvil A; Bernardo N; Rogers T; Koifman E; Buchanan K; Alraies MC; Shults C; Torguson R; Okubagzi PG; Pichard AD; Satler LF; Ben-Dor I; Waksman R
    Cardiovasc Revasc Med; 2017 Mar; 18(2):128-132. PubMed ID: 27865711
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Totally Percutaneous Transfemoral Transcatheter Aortic Valve Replacement Despite Failure to Deploy a Vascular Closure Device: A Single-Centre Case Series.
    Eitan A; Shiran A; Sliman H; Zafrir B; Jaffe R
    Heart Lung Circ; 2022 Mar; 31(3):390-394. PubMed ID: 34607752
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Outcome of Stent Graft Implantation for Treatment of Access Site Bleeding After Transfemoral Transcatheter Aortic Valve Replacement.
    Segal A; Flugelman MY; Khader N; Rubinshtein R; Lavi I; Karmeli R; Jubran A; Shiran A; Jaffe R
    Am J Cardiol; 2017 Aug; 120(3):456-460. PubMed ID: 28583682
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The safety and efficacy of temporary distal aortic occlusion to facilitate TAVR large-bore arterial closure.
    Bowers B; Anderson J; Brown D
    J Invasive Cardiol; 2014 Aug; 26(8):394-6. PubMed ID: 25091100
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Complete percutaneous approach for arterial access in transfemoral transcatheter aortic valve replacement: a comparison with surgical cut-down and closure.
    Nakamura M; Chakravarty T; Jilaihawi H; Doctor N; Dohad S; Fontana G; Cheng W; Makkar RR
    Catheter Cardiovasc Interv; 2014 Aug; 84(2):293-300. PubMed ID: 23873857
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Stent fractures after common femoral artery bail-out stenting due to suture device failure in TAVR.
    Veulemans V; Afzal S; Ledwig P; Heiss C; Busch L; Sansone R; Soetemann DB; Maier O; Kleinebrecht L; Kelm M; Zeus T; Hellhammer K
    Vasa; 2018 Aug; 47(5):393-401. PubMed ID: 29952252
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Retrograde Femoral Artery Stent-Graft Implantation for Treatment of Access-site Bleeding Following Transcatheter Aortic Valve Implantation.
    Sliman H; Shiran A; Mannheim D; Avraham E; Karmeli R; Khader N; Zafrir B; Rubinshtein R; Jaffe R
    Isr Med Assoc J; 2019 May; 21(5):322-325. PubMed ID: 31140223
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The adjunctive use of Angio-Seal in femoral vascular closure following percutaneous transcatheter aortic valve replacement.
    Kiramijyan S; Magalhaes MA; Ben-Dor I; Koifman E; Escarcega RO; Baker NC; Torguson R; Okubagzi P; Bernardo NL; Satler LF; Pichard AD; Waksman R
    EuroIntervention; 2016 May; 12(1):88-93. PubMed ID: 27173868
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact of percutaneous femoral arteriotomy closure using the MANTA
    De Palma R; Settergren M; Rück A; Linder R; Saleh N
    Catheter Cardiovasc Interv; 2018 Nov; 92(5):954-961. PubMed ID: 29575678
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Simplified Trans-Axillary Aortic Valve Replacement Under Local Anesthesia - A Single-Center Early Experience.
    Ooms JF; Van Wiechen MP; Hokken TW; Goudzwaard J; De Ronde-Tillmans MJ; Daemen J; Mattace-Raso F; De Jaegere PP; Van Mieghem NM
    Cardiovasc Revasc Med; 2021 Feb; 23():7-13. PubMed ID: 33281073
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Transcatheter Paravalvular Leak Closure With Covered Stent Tract and Vascular Plug: Tootsie Roll Technique.
    Ueyama HA; Greenbaum AB; Xie JX; Shekiladze N; Gleason PT; Byku I; Devireddy CM; Hanzel GS; Block PC; Babaliaros VC
    JACC Cardiovasc Interv; 2024 Mar; 17(5):635-644. PubMed ID: 38244000
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Routine Endovascular Treatment With a Stent Graft for Access-Site and Access-Related Vascular Injury in Transfemoral Transcatheter Aortic Valve Implantation.
    Sedaghat A; Neumann N; Schahab N; Sinning JM; Hammerstingl C; Pingel S; Schaefer C; Mellert F; Schiller W; Welz A; Grube E; Nickenig G; Werner N
    Circ Cardiovasc Interv; 2016 Aug; 9(8):. PubMed ID: 27512089
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Suprasternal Transcatheter Aortic Valve Replacement in Patients With Marginal Femoral Access.
    Kiser AC; Caranasos TG; Peterson MD; Holzhey DM; Kiefer P; Nifong LW; Borger MA
    Innovations (Phila); 2018; 13(1):1-4. PubMed ID: 29462049
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Safety and efficacy of using the Viabahn endoprosthesis for percutaneous treatment of vascular access complications after transfemoral aortic valve implantation.
    De Backer O; Arnous S; Sandholt B; Brooks M; Biasco L; Franzen O; Lönn L; Bech B; Søndergaard L
    Am J Cardiol; 2015 Apr; 115(8):1123-9. PubMed ID: 25728645
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Symetis Acurate Transapical Aortic Valve: the initial experience with a second generation of transcatheter aortic valve replacement device.
    Zembala MO; Piegza J; Wacławski J; Hawranek M; Hilker M; Niklewski T; Głowacki J; Parys M; Nadziakiewicz P; Chodór P; Wilczek K; Przybylski R; Gąsior M; Zembala M
    Kardiol Pol; 2014; 72(2):187-93. PubMed ID: 24604504
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Angiographic Analysis of Vascular Integrity After Percutaneous Closure Using Prostar XL Device During Transcatheter Aortic Valve Implantation.
    Lareyre F; Raffort J; Dommerc C; Benhammamia M; Bourlon F; Habib Y; Mialhe C
    Vasc Endovascular Surg; 2017 Jul; 51(5):282-287. PubMed ID: 28474978
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Impact of routine crossover balloon occlusion technique on access-related vascular complications following transfemoral transcatheter aortic valve replacement.
    Zaman S; Gooley R; Cheng V; McCormick L; Meredith IT
    Catheter Cardiovasc Interv; 2016 Aug; 88(2):276-84. PubMed ID: 27107395
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Strategy for Totally Percutaneous Management of Vascular Injury in Combined Transfemoral Transcatheter Aortic Valve Replacement and Endovascular Aortic Aneurysm Repair Procedures.
    Naoum I; Eitan A; Galili O; Hayeq H; Shiran A; Zissman K; Sliman H; Jaffe R
    Am J Cardiol; 2023 Nov; 207():130-136. PubMed ID: 37738782
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The Carotid Artery as a Preferred Alternative Access Route for Transcatheter Aortic Valve Replacement.
    Kirker EB; Hodson RW; Spinelli KJ; Korngold EC
    Ann Thorac Surg; 2017 Aug; 104(2):621-629. PubMed ID: 28274520
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Long term follow-up after balloon expandable covered stents implantation for management of transcatheter aortic valve replacement related vascular access complications.
    Maurina M; Condello F; Mangieri A; Sanz-Sanchez J; Stefanini GG; Bongiovanni D; Cozzi O; Leone PP; Baggio S; Gasparini G; Pagnotta P; Civilini E; Colombo A; Reimers B; Regazzoli D
    Catheter Cardiovasc Interv; 2022 Nov; 100(5):903-909. PubMed ID: 36040688
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 41.