These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
410 related articles for article (PubMed ID: 27866140)
1. One-year outcomes with two suture-mediated closure devices to achieve access-site haemostasis following transfemoral transcatheter aortic valve implantation. Mehilli J; Jochheim D; Abdel-Wahab M; Rizas KD; Theiss H; Spenkuch N; Zadrozny M; Baquet M; El-Mawardy M; Sato T; Lange P; Kuppatt C; Greif M; Hausleiter J; Bauer A; Schwarz F; Pichlmaier M; Hagl C; Richardt G; Massberg S EuroIntervention; 2016 Nov; 12(10):1298-1304. PubMed ID: 27866140 [TBL] [Abstract][Full Text] [Related]
2. Impact of suture mediated femoral access site closure with the Prostar XL compared to the ProGlide system on outcome in transfemoral aortic valve implantation. Seeger J; Gonska B; Rodewald C; Rottbauer W; Wöhrle J Int J Cardiol; 2016 Nov; 223():564-567. PubMed ID: 27561160 [TBL] [Abstract][Full Text] [Related]
3. Comparison of suture-based vascular closure devices in transfemoral transcatheter aortic valve implantation. Barbanti M; Capranzano P; Ohno Y; Gulino S; Sgroi C; Immè S; Tamburino C; Cannata S; Patanè M; Di Stefano D; Todaro D; Di Simone E; Deste W; Gargiulo G; Capodanno D; Grasso C; Tamburino C EuroIntervention; 2015 Oct; 11(6):690-7. PubMed ID: 26499222 [TBL] [Abstract][Full Text] [Related]
4. Comparison of vascular closure devices for access site closure after transfemoral aortic valve implantation. Barbash IM; Barbanti M; Webb J; Molina-Martin De Nicolas J; Abramowitz Y; Latib A; Nguyen C; Deuschl F; Segev A; Sideris K; Buccheri S; Simonato M; Rosa FD; Tamburino C; Jilaihawi H; Miyazaki T; Himbert D; Schofer N; Guetta V; Bleiziffer S; Tchetche D; Immè S; Makkar RR; Vahanian A; Treede H; Lange R; Colombo A; Dvir D Eur Heart J; 2015 Dec; 36(47):3370-9. PubMed ID: 26314688 [TBL] [Abstract][Full Text] [Related]
5. Comparative data of single versus double proglide vascular preclose technique after percutaneous transfemoral transcatheter aortic valve implantation from the optimized catheter valvular intervention (OCEAN-TAVI) japanese multicenter registry. Kodama A; Yamamoto M; Shimura T; Kagase A; Koyama Y; Tada N; Takagi K; Araki M; Yamanaka F; Shirai S; Watanabe Y; Hayashida K Catheter Cardiovasc Interv; 2017 Sep; 90(3):E55-E62. PubMed ID: 27785881 [TBL] [Abstract][Full Text] [Related]
6. Efficacy and Safety of ProGlide Versus Prostar XL Vascular Closure Devices in Transcatheter Aortic Valve Replacement: The RISPEVA Registry. Berti S; Bedogni F; Giordano A; Petronio AS; Iadanza A; Bartorelli AL; Reimers B; Spaccarotella C; Trani C; Attisano T; Marella Cenname A; Sardella G; Bonmassari R; Medda M; Tomai F; Tarantini G; Navarese EP; J Am Heart Assoc; 2020 Nov; 9(21):e018042. PubMed ID: 33103545 [TBL] [Abstract][Full Text] [Related]
7. Femoral access-related complications during percutaneous transcatheter aortic valve implantation comparing single versus double Prostar XL device closure. Saleh N; De Palma R; Settergren M; Rück A Catheter Cardiovasc Interv; 2015 Dec; 86(7):1255-61. PubMed ID: 26332528 [TBL] [Abstract][Full Text] [Related]
8. Simple, effective and safe vascular access site closure with the double-ProGlide preclose technique in 162 patients receiving transfemoral transcatheter aortic valve implantation. Griese DP; Reents W; Diegeler A; Kerber S; Babin-Ebell J Catheter Cardiovasc Interv; 2013 Nov; 82(5):E734-41. PubMed ID: 23765732 [TBL] [Abstract][Full Text] [Related]
10. Impact of closure devices on vascular complication and mortality rates in TAVI procedures. Dimitriadis Z; Scholtz W; Börgermann J; Wiemer M; Piper C; Vlachojannis M; Gummert J; Horstkotte D; Ensminger S; Faber L; Scholtz S Int J Cardiol; 2017 Aug; 241():133-137. PubMed ID: 28153535 [TBL] [Abstract][Full Text] [Related]
11. Angiographic Analysis of Vascular Integrity After Percutaneous Closure Using Prostar XL Device During Transcatheter Aortic Valve Implantation. Lareyre F; Raffort J; Dommerc C; Benhammamia M; Bourlon F; Habib Y; Mialhe C Vasc Endovascular Surg; 2017 Jul; 51(5):282-287. PubMed ID: 28474978 [TBL] [Abstract][Full Text] [Related]
12. Comparison of ProGlide vs. Prostar in patients undergoing transcatheter aortic valve implantation. Giordano A; Corcione N; Ferraro P; Morello A; Conte S; Testa L; Iadanza A; Sardella G; Mancone M; Berti S; Petronio AS; Romagnoli E; Pepe M; Frati G; Biondi-Zoccai G; Minerva Cardioangiol; 2019 Dec; 67(6):443-449. PubMed ID: 31670491 [TBL] [Abstract][Full Text] [Related]
13. Ultrasound-guided deployment of ProGlide™ device in transfemoral transcatheter aortic valve implantation and risk reduction of vascular complications: A propensity-matched cohort study. Ross DS; Nogic J; Cong H; Nuzzi V; Thanikachalam P; Veenuraju S; Gruner-Hegge N; Anwar M; O'Sullivan M; Costopoulos C; Davies WR; Costanzo P Catheter Cardiovasc Interv; 2024 Apr; 103(5):771-781. PubMed ID: 38451155 [TBL] [Abstract][Full Text] [Related]
14. Impact of femoral artery puncture using digital subtraction angiography and road mapping on vascular and bleeding complications after transfemoral transcatheter aortic valve implantation. El-Mawardy M; Schwarz B; Landt M; Sulimov D; Kebernik J; Allali A; Becker B; Toelg R; Richardt G; Abdel-Wahab M EuroIntervention; 2017 Jan; 12(13):1667-1673. PubMed ID: 28106001 [TBL] [Abstract][Full Text] [Related]
15. Propensity-matched comparison between Direct Flow Medical, Medtronic Corevalve, and Edwards Sapien XT prostheses: Device success, thirty-day safety, and mortality. Zhang Y; Pyxaras SA; Wolf A; Schmitz T; Naber CK Catheter Cardiovasc Interv; 2015 Jun; 85(7):1217-25. PubMed ID: 25581785 [TBL] [Abstract][Full Text] [Related]
16. Early Outcomes After Percutaneous Closure of Access Site in Transfemoral Transcatheter Valve Implantation Using the Novel Vascular Closure Device Collagen Plug-Based MANTA. Gheorghe L; Brouwer J; Mathijssen H; Nijenhuis VJ; Rensing BJ; Swaans MJ; Chan Pin Yin DR; Heijmen RH; De Kroon T; Sonker U; Van der Heyden JA; Ten Berg JM Am J Cardiol; 2019 Oct; 124(8):1265-1271. PubMed ID: 31443900 [TBL] [Abstract][Full Text] [Related]
17. The adjunctive use of Angio-Seal in femoral vascular closure following percutaneous transcatheter aortic valve replacement. Kiramijyan S; Magalhaes MA; Ben-Dor I; Koifman E; Escarcega RO; Baker NC; Torguson R; Okubagzi P; Bernardo NL; Satler LF; Pichard AD; Waksman R EuroIntervention; 2016 May; 12(1):88-93. PubMed ID: 27173868 [TBL] [Abstract][Full Text] [Related]
18. Impact of percutaneous femoral arteriotomy closure using the MANTA De Palma R; Settergren M; Rück A; Linder R; Saleh N Catheter Cardiovasc Interv; 2018 Nov; 92(5):954-961. PubMed ID: 29575678 [TBL] [Abstract][Full Text] [Related]
19. The novel echo-guided ProGlide technique during percutaneous transfemoral transcatheter aortic valve implantation. Honda Y; Araki M; Yamawaki M; Tokuda T; Tsutumi M; Mori S; Sakamoto Y; Kobayashi N; Hirano K; Ito Y J Interv Cardiol; 2018 Apr; 31(2):216-222. PubMed ID: 29193337 [TBL] [Abstract][Full Text] [Related]
20. Single suture-mediated closure system after transfemoral transcatheter aortic valve implantation: A single-center real-world experience. Iacovelli F; Burattini O; Sturdà F; Branca M; Stabile E; Fimiani L; Salemme L; Cioppa A; Pucciarelli A; Cafaro A; Bortone AS; Contegiacomo G; Pignatelli A; Tesorio T Catheter Cardiovasc Interv; 2024 Jun; 103(7):1125-1137. PubMed ID: 38639140 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]