These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

326 related articles for article (PubMed ID: 27869059)

  • 1. Site-Specific Preparation of Intact Solid-Liquid Interfaces by Label-Free In Situ Localization and Cryo-Focused Ion Beam Lift-Out.
    Zachman MJ; Asenath-Smith E; Estroff LA; Kourkoutis LF
    Microsc Microanal; 2016 Dec; 22(6):1338-1349. PubMed ID: 27869059
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Advanced cryo-tomography workflow developments - correlative microscopy, milling automation and cryo-lift-out.
    Kuba J; Mitchels J; Hovorka M; Erdmann P; Berka L; Kirmse R; KÖnig J; DE Bock J; Goetze B; Rigort A
    J Microsc; 2021 Feb; 281(2):112-124. PubMed ID: 32557536
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Cryo-STEM mapping of solid-liquid interfaces and dendrites in lithium-metal batteries.
    Zachman MJ; Tu Z; Choudhury S; Archer LA; Kourkoutis LF
    Nature; 2018 Aug; 560(7718):345-349. PubMed ID: 30111789
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Nanoscale Characterization of Liquid-Solid Interfaces by Coupling Cryo-Focused Ion Beam Milling with Scanning Electron Microscopy and Spectroscopy.
    Moon T; Colletta M; Kourkoutis LF
    J Vis Exp; 2022 Jul; (185):. PubMed ID: 35913136
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Cryo-FIB for TEM investigation of soft matter and beam sensitive energy materials.
    Long DM; Singh MK; Small KA; Watt J
    Nanotechnology; 2022 Oct; 33(50):. PubMed ID: 36121746
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A focused ion beam milling and lift-out approach for site-specific preparation of frozen-hydrated lamellas from multicellular organisms.
    Mahamid J; Schampers R; Persoon H; Hyman AA; Baumeister W; Plitzko JM
    J Struct Biol; 2015 Nov; 192(2):262-9. PubMed ID: 26216184
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cryo-focused-ion-beam applications in structural biology.
    Rigort A; Plitzko JM
    Arch Biochem Biophys; 2015 Sep; 581():122-30. PubMed ID: 25703192
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cryo-FIB-lift-out: practically impossible to practical reality.
    Parmenter CD; Nizamudeen ZA
    J Microsc; 2021 Feb; 281(2):157-174. PubMed ID: 32815145
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An introduction to cryo-FIB-SEM cross-sectioning of frozen, hydrated Life Science samples.
    Hayles MF; DE Winter DAM
    J Microsc; 2021 Feb; 281(2):138-156. PubMed ID: 32737879
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Making the practically impossible "Merely difficult"--Cryogenic FIB lift-out for "Damage free" soft matter imaging.
    Parmenter CD; Fay MW; Hartfield C; Eltaher HM
    Microsc Res Tech; 2016 Apr; 79(4):298-303. PubMed ID: 26875988
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Understanding Ion-Beam Damage to Air-Sensitive Lithium Metal With Cryogenic Electron and Ion Microscopy.
    Koh H; Detsi E; Stach EA
    Microsc Microanal; 2023 Jul; 29(4):1350-1356. PubMed ID: 37488829
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In situ Microfluidic Cryofixation for Cryo Focused Ion Beam Milling and Cryo Electron Tomography.
    Fuest M; Schaffer M; Nocera GM; Galilea-Kleinsteuber RI; Messling JE; Heymann M; Plitzko JM; Burg TP
    Sci Rep; 2019 Dec; 9(1):19133. PubMed ID: 31836773
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A cryo-FIB lift-out technique enables molecular-resolution cryo-ET within native Caenorhabditis elegans tissue.
    Schaffer M; Pfeffer S; Mahamid J; Kleindiek S; Laugks T; Albert S; Engel BD; Rummel A; Smith AJ; Baumeister W; Plitzko JM
    Nat Methods; 2019 Aug; 16(8):757-762. PubMed ID: 31363205
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cryo-FIB preparation of whole cells and tissue for cryo-TEM: use of high-pressure frozen specimens in tubes and planchets.
    DE Winter DAM; Hsieh C; Marko M; Hayles MF
    J Microsc; 2021 Feb; 281(2):125-137. PubMed ID: 32691851
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Site-Specific Cryo-focused Ion Beam Sample Preparation Guided by 3D Correlative Microscopy.
    Arnold J; Mahamid J; Lucic V; de Marco A; Fernandez JJ; Laugks T; Mayer T; Hyman AA; Baumeister W; Plitzko JM
    Biophys J; 2016 Feb; 110(4):860-9. PubMed ID: 26769364
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Optimized cryo-focused ion beam sample preparation aimed at in situ structural studies of membrane proteins.
    Schaffer M; Mahamid J; Engel BD; Laugks T; Baumeister W; Plitzko JM
    J Struct Biol; 2017 Feb; 197(2):73-82. PubMed ID: 27444390
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Preparing Lamellae from Vitreous Biological Samples using a Dual-Beam Scanning Electron Microscope for Cryo-Electron Tomography.
    Bisson C; Hecksel CW; Gilchrist JB; Carbajal MA; Fleck RA
    J Vis Exp; 2021 Aug; (174):. PubMed ID: 34424237
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A site-specific focused-ion-beam lift-out method for cryo Transmission Electron Microscopy.
    Rubino S; Akhtar S; Melin P; Searle A; Spellward P; Leifer K
    J Struct Biol; 2012 Dec; 180(3):572-6. PubMed ID: 23000702
    [TBL] [Abstract][Full Text] [Related]  

  • 19. VHUT-cryo-FIB, a method to fabricate frozen hydrated lamellae from tissue specimens for in situ cryo-electron tomography.
    Zhang J; Zhang D; Sun L; Ji G; Huang X; Niu T; Xu J; Ma C; Zhu Y; Gao N; Xu W; Sun F
    J Struct Biol; 2021 Sep; 213(3):107763. PubMed ID: 34174447
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Quantification of gallium cryo-FIB milling damage in biological lamellae.
    Lucas BA; Grigorieff N
    Proc Natl Acad Sci U S A; 2023 Jun; 120(23):e2301852120. PubMed ID: 37216561
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.