These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

69 related articles for article (PubMed ID: 2786940)

  • 41. Single Photon Emission Computed Tomography (SPECT) Myocardial Perfusion Imaging Guidelines: Instrumentation, Acquisition, Processing, and Interpretation.
    Dorbala S; Ananthasubramaniam K; Armstrong IS; Chareonthaitawee P; DePuey EG; Einstein AJ; Gropler RJ; Holly TA; Mahmarian JJ; Park MA; Polk DM; Russell R; Slomka PJ; Thompson RC; Wells RG
    J Nucl Cardiol; 2018 Oct; 25(5):1784-1846. PubMed ID: 29802599
    [No Abstract]   [Full Text] [Related]  

  • 42. A Comparison of Iterative Reconstruction and Prone Imaging in Reducing the Inferior Wall Attenuation in Tc-99m Sestamibi Myocardial Perfusion SPECT.
    Kuşlu D; Öztürk E
    Mol Imaging Radionucl Ther; 2017 Oct; 26(3):110-115. PubMed ID: 28976333
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Comparison of CTAC and prone imaging for the detection of coronary artery disease using CZT SPECT.
    Ito S; Endo A; Okada T; Nakamura T; Sugamori T; Takahashi N; Yoshitomi H; Tanabe K
    Ann Nucl Med; 2017 Oct; 31(8):629-635. PubMed ID: 28695497
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Comparative accuracy of supine-only and combined supine-prone myocardial perfusion imaging in men.
    Taasan V; Wokhlu A; Taasan MV; Dusaj RS; Mehta A; Kraft S; Winchester D; Wymer D
    J Nucl Cardiol; 2016 Dec; 23(6):1470-1476. PubMed ID: 26719152
    [TBL] [Abstract][Full Text] [Related]  

  • 45. The Benefits of Prone SPECT Myocardial Perfusion Imaging in Reducing Both Artifact Defects and Patient Radiation Exposure.
    Stathaki M; Koukouraki S; Papadaki E; Tsaroucha A; Karkavitsas N
    Arq Bras Cardiol; 2015 Oct; 105(4):345-52. PubMed ID: 26559981
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Single photon-emission computed tomography.
    Holly TA; Abbott BG; Al-Mallah M; Calnon DA; Cohen MC; DiFilippo FP; Ficaro EP; Freeman MR; Hendel RC; Jain D; Leonard SM; Nichols KJ; Polk DM; Soman P;
    J Nucl Cardiol; 2010 Oct; 17(5):941-73. PubMed ID: 20552312
    [No Abstract]   [Full Text] [Related]  

  • 47. Supine acceptance of a conventional imaging position may make you less prone to success.
    Germano G; Slomka PJ; Berman DS
    J Nucl Cardiol; 2010; 17(1):16-8. PubMed ID: 20035389
    [No Abstract]   [Full Text] [Related]  

  • 48. Rest and low-dose dobutamine Tc-99m-mibi gated-SPECT for early prediction of left ventricular remodeling after a first reperfused myocardial infarction.
    Ernande L; Cachin F; Chabrot P; Durel N; Morand D; Boyer L; Maublant J; Lipiecki J
    J Nucl Cardiol; 2009; 16(4):597-604. PubMed ID: 19479315
    [TBL] [Abstract][Full Text] [Related]  

  • 49. SPECT myocardial perfusion imaging with prone-only acquisitions: correlation with coronary angiography.
    Shin JH; Pokharna HK; Williams KA; Mehta R; Ward RP
    J Nucl Cardiol; 2009; 16(4):590-6. PubMed ID: 19466502
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Myocardial perfusion and function: single photon emission computed tomography.
    Hansen CL; Goldstein RA; Akinboboye OO; Berman DS; Botvinick EH; Churchwell KB; Cooke CD; Corbett JR; Cullom SJ; Dahlberg ST; Druz RS; Ficaro EP; Galt JR; Garg RK; Germano G; Heller GV; Henzlova MJ; Hyun MC; Johnson LL; Mann A; McCallister BD; Quaife RA; Ruddy TD; Sundaram SN; Taillefer R; Ward RP; Mahmarian JJ;
    J Nucl Cardiol; 2007; 14(6):e39-60. PubMed ID: 18022099
    [No Abstract]   [Full Text] [Related]  

  • 51. Myocardial perfusion and function single photon emission computed tomography.
    Hansen CL; Goldstein RA; Berman DS; Churchwell KB; Cooke CD; Corbett JR; Cullom SJ; Dahlberg ST; Galt JR; Garg RK; Heller GV; Hyun MC; Johnson LL; Mann A; McCallister BD; Taillefer R; Ward RP; Mahmarian JJ;
    J Nucl Cardiol; 2006 Nov; 13(6):e97-120. PubMed ID: 17174800
    [No Abstract]   [Full Text] [Related]  

  • 52. Diagnostic accuracy of gated Tc-99m sestamibi stress myocardial perfusion SPECT with combined supine and prone acquisitions to detect coronary artery disease in obese and nonobese patients.
    Berman DS; Kang X; Nishina H; Slomka PJ; Shaw LJ; Hayes SW; Cohen I; Friedman JD; Gerlach J; Germano G
    J Nucl Cardiol; 2006; 13(2):191-201. PubMed ID: 16580955
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Quantitative Tc-99m sestamibi attenuation-corrected SPECT: development and multicenter trial validation of myocardial perfusion stress gender-independent normal database in an obese population.
    Grossman GB; Garcia EV; Bateman TM; Heller GV; Johnson LL; Folks RD; Cullom SJ; Galt JR; Case JA; Santana CA; Halkar RK
    J Nucl Cardiol; 2004; 11(3):263-72. PubMed ID: 15173773
    [TBL] [Abstract][Full Text] [Related]  

  • 54. The higher likelihood of developing cardiomegaly during follow-up in patients with syndrome X and abnormal thallium-201 myocardial perfusion SPECT.
    Sun SS; Huang JL; Tsai SC; Ho YJ; Kao CH
    Int J Cardiovasc Imaging; 2001 Aug; 17(4):271-8. PubMed ID: 11599866
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Comparison of post-stress ejection fraction and relative left ventricular volumes by automatic analysis of gated myocardial perfusion single-photon emission computed tomography acquired in the supine and prone positions.
    Berman D; Germano G; Lewin H; Kang X; Kavanagh PB; Tapnio P; Harris M; Friedman J
    J Nucl Cardiol; 1998; 5(1):40-7. PubMed ID: 9504872
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Attenuation correction by simultaneous emission-transmission myocardial single-photon emission tomography using a technetium-99m-labelled radiotracer: impact on diagnostic accuracy.
    Kluge R; Sattler B; Seese A; Knapp WH
    Eur J Nucl Med; 1997 Sep; 24(9):1107-14. PubMed ID: 9283102
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Is 'diaphragmatic' attenuation a misnomer?. Evaluation of the anatomic cause of 'diaphragmatic' attenuation in SPECT thallium scanning.
    Elson SH; Clark WS; Williams BR
    Int J Card Imaging; 1997 Apr; 13(2):161-4. PubMed ID: 9110195
    [TBL] [Abstract][Full Text] [Related]  

  • 58. What is the current status of quantification and nuclear medicine in cardiology?
    Hör G
    Eur J Nucl Med; 1996 Jul; 23(7):815-51. PubMed ID: 8662122
    [No Abstract]   [Full Text] [Related]  

  • 59. Prone decubitus: a solution to inferior wall attenuation in thallium-201 myocardial tomography.
    Esquerré JP; Coca FJ; Martinez SJ; Guiraud RF
    J Nucl Med; 1989 Mar; 30(3):398-401. PubMed ID: 2786940
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Prone versus supine thallium myocardial SPECT: a method to decrease artifactual inferior wall defects.
    Segall GM; Davis MJ
    J Nucl Med; 1989 Apr; 30(4):548-55. PubMed ID: 2661750
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 4.