BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

291 related articles for article (PubMed ID: 27870824)

  • 1. Efficacy of a Dehydrated Hydrogel Plug to Reduce Complications Associated With Computed Tomography-guided Percutaneous Transthoracic Needle Biopsy.
    Grage RA; Naveed MA; Keogh S; Wang D
    J Thorac Imaging; 2017 Jan; 32(1):57-62. PubMed ID: 27870824
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A lung biopsy tract plug for reduction of postbiopsy pneumothorax and other complications: results of a prospective, multicenter, randomized, controlled clinical study.
    Zaetta JM; Licht MO; Fisher JS; Avelar RL;
    J Vasc Interv Radiol; 2010 Aug; 21(8):1235-43.e1-3. PubMed ID: 20656223
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Effect of Needle Gauge on the Risk of Pneumothorax and Chest Tube Placement After Percutaneous Computed Tomographic (CT)-Guided Lung Biopsy.
    Kuban JD; Tam AL; Huang SY; Ensor JE; Philip AS; Chen GJ; Ahrar J; Murthy R; Avritscher R; Madoff DC; Mahvash A; Ahrar K; Wallace MJ; Nachiappan AC; Gupta S
    Cardiovasc Intervent Radiol; 2015 Dec; 38(6):1595-602. PubMed ID: 25920917
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Efficacy of the tract embolization technique with gelatin sponge slurry to reduce pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy.
    Renier H; Gérard L; Lamborelle P; Cousin F
    Cardiovasc Intervent Radiol; 2020 Apr; 43(4):597-603. PubMed ID: 31792589
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The effect of intraparenchymal blood patching on the rate of pneumothorax in patients undergoing percutaneous CT-guided core biopsy of the lung.
    Perl RM; Risse E; Hetzel J; Bösmüller H; Kloth C; Fritz J; Horger M
    Eur J Radiol; 2019 Jul; 116():14-20. PubMed ID: 31153555
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Nonclotted Blood Patch Technique Reduces Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsies.
    Clayton JD; Elicker BM; Ordovas KG; Kohi MP; Nguyen J; Naeger DM
    J Thorac Imaging; 2016 Jul; 31(4):243-6. PubMed ID: 27105052
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Pulmonary Intraparenchymal Blood Patching Decreases the Rate of Pneumothorax-Related Complications following Percutaneous CT-Guided Needle Biopsy.
    Graffy P; Loomis SB; Pickhardt PJ; Lubner MG; Kitchin DR; Lee FT; Hinshaw JL
    J Vasc Interv Radiol; 2017 Apr; 28(4):608-613.e1. PubMed ID: 28185770
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Transthoracic Computed Tomography-Guided Lung Nodule Biopsy: Comparison of Core Needle and Fine Needle Aspiration Techniques.
    Sangha BS; Hague CJ; Jessup J; O'Connor R; Mayo JR
    Can Assoc Radiol J; 2016 Aug; 67(3):284-9. PubMed ID: 27005931
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Pneumothorax Incidence with Normal Saline Instillation for Sealing the Needle Track After Computed Tomography-Guided Percutaneous Lung Biopsy.
    Bourgeais G; Frampas E; Liberge R; Nicolas A; Defrance C; Blanc FX; Coudol S; Morla O
    Cardiovasc Intervent Radiol; 2024 May; 47(5):604-612. PubMed ID: 38263525
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Efficacy of a Self-expanding Tract Sealant Device in the Reduction of Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsy: A Matched Controlled Study Using Propensity Score Analysis.
    Ahrar JU; Gupta S; Ensor JE; Mahvash A; Sabir SH; Steele JR; McRae SE; Avritscher R; Huang SY; Odisio BC; Murthy R; Ahrar K; Wallace MJ; Tam AL
    Cardiovasc Intervent Radiol; 2017 Feb; 40(2):270-276. PubMed ID: 27826786
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Rapid needle-out patient-rollover time after percutaneous CT-guided transthoracic biopsy of lung nodules: effect on pneumothorax rate.
    O'Neill AC; McCarthy C; Ridge CA; Mitchell P; Hanrahan E; Butler M; Keane MP; Dodd JD
    Radiology; 2012 Jan; 262(1):314-9. PubMed ID: 22106349
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dependent lesion positioning at CT-guided lung biopsy to reduce risk of pneumothorax.
    Appel E; Dommaraju S; Camacho A; Nakhaei M; Siewert B; Ahmed M; Brook A; Brook OR
    Eur Radiol; 2020 Nov; 30(11):6369-6375. PubMed ID: 32591892
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Core Lung Biopsy for Biomarker Analysis: Is There Increased Risk Compared With Conventional Biopsy?
    Sheth S; Jilani D; Bos A; Ahmed O; Patel M; Zangan S
    J Thorac Imaging; 2015 Sep; 30(5):314-8. PubMed ID: 25961378
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Tract embolization with gelatin sponge slurry for prevention of pneumothorax after percutaneous computed tomography-guided lung biopsy.
    Tran AA; Brown SB; Rosenberg J; Hovsepian DM
    Cardiovasc Intervent Radiol; 2014 Dec; 37(6):1546-53. PubMed ID: 24366313
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Risk factors influencing chest tube placement among patients with pneumothorax because of CT-guided needle biopsy of the lung.
    Nakamura M; Yoshizako T; Koyama S; Kitagaki H
    J Med Imaging Radiat Oncol; 2011 Oct; 55(5):474-8. PubMed ID: 22008165
    [TBL] [Abstract][Full Text] [Related]  

  • 16. CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate.
    Geraghty PR; Kee ST; McFarlane G; Razavi MK; Sze DY; Dake MD
    Radiology; 2003 Nov; 229(2):475-81. PubMed ID: 14595149
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pneumothorax Complicating Coaxial and Non-coaxial CT-Guided Lung Biopsy: Comparative Analysis of Determining Risk Factors and Management of Pneumothorax in a Retrospective Review of 650 Patients.
    Nour-Eldin NE; Alsubhi M; Emam A; Lehnert T; Beeres M; Jacobi V; Gruber-Rouh T; Scholtz JE; Vogl TJ; Naguib NN
    Cardiovasc Intervent Radiol; 2016 Feb; 39(2):261-70. PubMed ID: 26148648
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Usual Interstitial Pneumonia: Associations With Complications After Percutaneous Transthoracic Needle Lung Biopsy.
    Park J; Lee JH; Hong W; Hwang EJ; Yoon SH; Goo JM; Park CM
    AJR Am J Roentgenol; 2024 Feb; 222(2):e2329938. PubMed ID: 37910039
    [No Abstract]   [Full Text] [Related]  

  • 19. Rapid needle-out patient-rollover approach after cone beam CT-guided lung biopsy: effect on pneumothorax rate in 1,191 consecutive patients.
    Kim JI; Park CM; Lee SM; Goo JM
    Eur Radiol; 2015 Jul; 25(7):1845-53. PubMed ID: 25636421
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Efficacy of manual aspiration immediately after complicated pneumothorax in CT-guided lung biopsy.
    Yamagami T; Kato T; Iida S; Hirota T; Yoshimatsu R; Nishimura T
    J Vasc Interv Radiol; 2005 Apr; 16(4):477-83. PubMed ID: 15802447
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.