These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 27877937)

  • 1. Present status and future prospects of spherical aberration corrected TEM/STEM for study of nanomaterials
    Tanaka N
    Sci Technol Adv Mater; 2008 Jan; 9(1):014111. PubMed ID: 27877937
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Breaking the spherical and chromatic aberration barrier in transmission electron microscopy.
    Freitag B; Kujawa S; Mul PM; Ringnalda J; Tiemeijer PC
    Ultramicroscopy; 2005 Feb; 102(3):209-14. PubMed ID: 15639351
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Current and future aberration correctors for the improvement of resolution in electron microscopy.
    Haider M; Hartel P; Müller H; Uhlemann S; Zach J
    Philos Trans A Math Phys Eng Sci; 2009 Sep; 367(1903):3665-82. PubMed ID: 19687059
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Using a monochromator to improve the resolution in TEM to below 0.5Å. Part I: Creating highly coherent monochromated illumination.
    Tiemeijer PC; Bischoff M; Freitag B; Kisielowski C
    Ultramicroscopy; 2012 Mar; 114():72-81. PubMed ID: 22356791
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Aberration-corrected STEM/TEM imaging at 15kV.
    Sasaki T; Sawada H; Hosokawa F; Sato Y; Suenaga K
    Ultramicroscopy; 2014 Oct; 145():50-5. PubMed ID: 24842229
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Aberration corrected STEM by means of diffraction gratings.
    Linck M; Ercius PA; Pierce JS; McMorran BJ
    Ultramicroscopy; 2017 Nov; 182():36-43. PubMed ID: 28651199
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Atomic-resolution STEM in the aberration-corrected JEOL JEM2200FS.
    Klie RF; Johnson C; Zhu Y
    Microsc Microanal; 2008 Feb; 14(1):104-12. PubMed ID: 18171499
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Probing structures of nanomaterials using advanced electron microscopy methods, including aberration-corrected electron microscopy at the Angstrom scale.
    Gai PL; Yoshida K; Shute C; Jia X; Walsh M; Ward M; Dresselhaus MS; Weertman JR; Boyes ED
    Microsc Res Tech; 2011 Jul; 74(7):664-70. PubMed ID: 20954265
    [TBL] [Abstract][Full Text] [Related]  

  • 9. 40 keV atomic resolution TEM.
    Bell DC; Russo CJ; Kolmykov DV
    Ultramicroscopy; 2012 Mar; 114():31-7. PubMed ID: 22356786
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Optimum aberration coefficients for recording high-resolution off-axis holograms in a Cs-corrected TEM.
    Linck M
    Ultramicroscopy; 2013 Jan; 124():77-87. PubMed ID: 23142748
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Background, status and future of the Transmission Electron Aberration-corrected Microscope project.
    Dahmen U; Erni R; Radmilovic V; Ksielowski C; Rossell MD; Denes P
    Philos Trans A Math Phys Eng Sci; 2009 Sep; 367(1903):3795-808. PubMed ID: 19687066
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Choice of operating voltage for a transmission electron microscope.
    Egerton RF
    Ultramicroscopy; 2014 Oct; 145():85-93. PubMed ID: 24679438
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Measurement of chromatic aberration in STEM and SCEM by coherent convergent beam electron diffraction.
    Zheng CL; Etheridge J
    Ultramicroscopy; 2013 Feb; 125():49-58. PubMed ID: 23274685
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Atomic and nanoscale imaging of a cellulose nanofiber and Pd nanoparticles composite using lower-voltage high-resolution TEM.
    Ohwada M; Mizukoshi Y; Shimokawa T; Hayashi N; Hayasaka Y; Konno TJ
    Microscopy (Oxf); 2017 Oct; 66(5):348-355. PubMed ID: 29016921
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Efficient phase contrast imaging in STEM using a pixelated detector. Part 1: experimental demonstration at atomic resolution.
    Pennycook TJ; Lupini AR; Yang H; Murfitt MF; Jones L; Nellist PD
    Ultramicroscopy; 2015 Apr; 151():160-167. PubMed ID: 25458189
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Future trends in aberration-corrected electron microscopy.
    Rose HH
    Philos Trans A Math Phys Eng Sci; 2009 Sep; 367(1903):3809-23. PubMed ID: 19687067
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Progress in aberration-corrected high-resolution transmission electron microscopy using hardware aberration correction.
    Lentzen M
    Microsc Microanal; 2006 Jun; 12(3):191-205. PubMed ID: 17481356
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Direct observation of a stacking fault in Si(1 - x)Ge(x) semiconductors by spherical aberration-corrected TEM and conventional ADF-STEM.
    Yamasaki J; Kawai T; Tanaka N
    J Electron Microsc (Tokyo); 2004; 53(2):129-35. PubMed ID: 15180207
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Chromatic Aberration Correction for Atomic Resolution TEM Imaging from 20 to 80 kV.
    Linck M; Hartel P; Uhlemann S; Kahl F; Müller H; Zach J; Haider M; Niestadt M; Bischoff M; Biskupek J; Lee Z; Lehnert T; Börrnert F; Rose H; Kaiser U
    Phys Rev Lett; 2016 Aug; 117(7):076101. PubMed ID: 27563976
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Possibilities and limitations of advanced transmission electron microscopy for carbon-based nanomaterials.
    Ke X; Bittencourt C; Van Tendeloo G
    Beilstein J Nanotechnol; 2015; 6():1541-57. PubMed ID: 26425406
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.