BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

189 related articles for article (PubMed ID: 27890567)

  • 1. Commissioning of the 4-D treatment delivery system for organ motion management in synchrotron-based scanning ion beams.
    Ciocca M; Mirandola A; Molinelli S; Russo S; Mastella E; Vai A; Mairani A; Magro G; Pella A; Donetti M; Valvo F; Fossati P; Baroni G
    Phys Med; 2016 Dec; 32(12):1667-1671. PubMed ID: 27890567
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Optimization of motion management parameters in a synchrotron-based spot scanning system.
    Johnson JE; Herman MG; Kruse JJ
    J Appl Clin Med Phys; 2019 Sep; 20(9):69-77. PubMed ID: 31538720
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Integration of a real-time tumor monitoring system into gated proton spot-scanning beam therapy: an initial phantom study using patient tumor trajectory data.
    Matsuura T; Miyamoto N; Shimizu S; Fujii Y; Umezawa M; Takao S; Nihongi H; Toramatsu C; Sutherland K; Suzuki R; Ishikawa M; Kinoshita R; Maeda K; Umegaki K; Shirato H
    Med Phys; 2013 Jul; 40(7):071729. PubMed ID: 23822433
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinical implementation of respiratory-gated spot-scanning proton therapy: An efficiency analysis of active motion management.
    Gelover E; Deisher AJ; Herman MG; Johnson JE; Kruse JJ; Tryggestad EJ
    J Appl Clin Med Phys; 2019 May; 20(5):99-108. PubMed ID: 30972922
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dosimetric commissioning and quality assurance of scanned ion beams at the Italian National Center for Oncological Hadrontherapy.
    Mirandola A; Molinelli S; Vilches Freixas G; Mairani A; Gallio E; Panizza D; Russo S; Ciocca M; Donetti M; Magro G; Giordanengo S; Orecchia R
    Med Phys; 2015 Sep; 42(9):5287-300. PubMed ID: 26328978
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Design and commissioning of the non-dedicated scanning proton beamline for ocular treatment at the synchrotron-based CNAO facility.
    Ciocca M; Magro G; Mastella E; Mairani A; Mirandola A; Molinelli S; Russo S; Vai A; Fiore MR; Mosci C; Valvo F; Via R; Baroni G; Orecchia R
    Med Phys; 2019 Apr; 46(4):1852-1862. PubMed ID: 30659616
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Efficient Interplay Effect Mitigation for Proton Pencil Beam Scanning by Spot-Adapted Layered Repainting Evenly Spread out Over the Full Breathing Cycle.
    Poulsen PR; Eley J; Langner U; Simone CB; Langen K
    Int J Radiat Oncol Biol Phys; 2018 Jan; 100(1):226-234. PubMed ID: 29254775
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Evaluation of absorbed dose in respiratory-gated radiotherapy using a phantom system that simulates patient respiration].
    Oyama M; Shinpo M; Goka T; Tanaka T; Ogino T
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2006 May; 62(5):742-8. PubMed ID: 16733503
    [TBL] [Abstract][Full Text] [Related]  

  • 9. 4D treatment planning for scanned ion beams.
    Bert C; Rietzel E
    Radiat Oncol; 2007 Jul; 2():24. PubMed ID: 17608919
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Measurement-based study on characterizing symmetric and asymmetric respiratory motion interplay effect on target dose distribution in the proton pencil beam scanning.
    Lee E; Perry D; Speth J; Zhang Y; Xiao Z; Mascia A
    J Appl Clin Med Phys; 2020 Apr; 21(4):59-67. PubMed ID: 32170992
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A statistical comparison of motion mitigation performances and robustness of various pencil beam scanned proton systems for liver tumour treatments.
    Zhang Y; Huth I; Weber DC; Lomax AJ
    Radiother Oncol; 2018 Jul; 128(1):182-188. PubMed ID: 29459153
    [TBL] [Abstract][Full Text] [Related]  

  • 12. End-to-end tests using alanine dosimetry in scanned proton beams.
    Carlino A; Gouldstone C; Kragl G; Traneus E; Marrale M; Vatnitsky S; Stock M; Palmans H
    Phys Med Biol; 2018 Feb; 63(5):055001. PubMed ID: 29384730
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Commissioning and quality assurance of a novel solution for respiratory-gated PBS proton therapy based on optical tracking of surface markers.
    Fattori G; Hrbacek J; Regele H; Bula C; Mayor A; Danuser S; Oxley DC; Rechsteiner U; Grossmann M; Via R; Böhlen TT; Bolsi A; Walser M; Togno M; Colvill E; Lempen D; Weber DC; Lomax AJ; Safai S
    Z Med Phys; 2022 Feb; 32(1):52-62. PubMed ID: 32830006
    [TBL] [Abstract][Full Text] [Related]  

  • 14. SU-E-T-395: Achievability and Optimization of Synchrotron-Based Respiratory Gated Spot Scanning Proton Beam Delivery.
    Tsunashima Y; Sahoo N; Sakae T; Poenisch F; Umezawa M; Briere T; Zhu X; Mohan R; Dong L
    Med Phys; 2012 Jun; 39(6Part16):3795. PubMed ID: 28517231
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Commissioning of a respiratory gating system involving a pressure sensor in carbon-ion scanning radiotherapy.
    Mizuno H; Saito O; Tajiri M; Kimura T; Kuroiwa D; Shirai T; Inaniwa T; Fukahori M; Miki K; Fukuda S
    J Appl Clin Med Phys; 2019 Jan; 20(1):37-42. PubMed ID: 30387271
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of two methods for minimizing the effect of delayed charge on the dose delivered with a synchrotron based discrete spot scanning proton beam.
    Whitaker TJ; Beltran C; Tryggestad E; Bues M; Kruse JJ; Remmes NB; Tasson A; Herman MG
    Med Phys; 2014 Aug; 41(8):081703. PubMed ID: 25086513
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The M. D. Anderson proton therapy system.
    Smith A; Gillin M; Bues M; Zhu XR; Suzuki K; Mohan R; Woo S; Lee A; Komaki R; Cox J; Hiramoto K; Akiyama H; Ishida T; Sasaki T; Matsuda K
    Med Phys; 2009 Sep; 36(9):4068-83. PubMed ID: 19810479
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Characteristics of gated treatment using an optical surface imaging and gating system on an Elekta linac.
    Freislederer P; Reiner M; Hoischen W; Quanz A; Heinz C; Walter F; Belka C; Soehn M
    Radiat Oncol; 2015 Mar; 10():68. PubMed ID: 25881018
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Impact of respiratory motion on proton pencil beam scanning FLASH radiotherapy: an
    Yang Y; Kang M; Huang S; Chen CC; Tsai P; Hu L; Yu F; Hajj C; Choi JI; Tome WA; Simone CB; Lin H
    Phys Med Biol; 2023 Apr; 68(8):. PubMed ID: 36944258
    [No Abstract]   [Full Text] [Related]  

  • 20. Respiratory gated irradiation system for heavy-ion radiotherapy.
    Minohara S; Kanai T; Endo M; Noda K; Kanazawa M
    Int J Radiat Oncol Biol Phys; 2000 Jul; 47(4):1097-103. PubMed ID: 10863083
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.