These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

502 related articles for article (PubMed ID: 27892840)

  • 41. Occlusal Thickness and Cement-Type Effects on Fracture Resistance of Implant-Supported Posterior Monolithic Zirconia Crowns.
    Bulut AC; Atsü SS
    Int J Oral Maxillofac Implants; 2021; 36(3):485-491. PubMed ID: 34115062
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Evaluation of load at fracture of Procera AllCeram copings using different luting cements.
    Al-Makramani BMA; Razak AAA; Abu-Hassan MI
    J Prosthodont; 2008 Feb; 17(2):120-124. PubMed ID: 18047490
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Microleakage of all-ceramic crowns using self-etching resin luting agents.
    Trajtenberg CP; Caram SJ; Kiat-amnuay S
    Oper Dent; 2008; 33(4):392-9. PubMed ID: 18666496
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Failure modes of Y-TZP crowns at different cusp inclines.
    Bonfante EA; Sailer I; Silva NR; Thompson VP; Dianne Rekow E; Coelho PG
    J Dent; 2010 Sep; 38(9):707-12. PubMed ID: 20382197
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Loading capacity of zirconia implant supported hybrid ceramic crowns.
    Rohr N; Coldea A; Zitzmann NU; Fischer J
    Dent Mater; 2015 Dec; 31(12):e279-88. PubMed ID: 26458762
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Strength and fracture pattern of monolithic CAD/CAM-generated posterior crowns.
    Bindl A; Lüthy H; Mörmann WH
    Dent Mater; 2006 Jan; 22(1):29-36. PubMed ID: 16040113
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Fatigue resistance and microleakage of CAD/CAM ceramic and composite molar crowns.
    Kassem AS; Atta O; El-Mowafy O
    J Prosthodont; 2012 Jan; 21(1):28-32. PubMed ID: 22008462
    [TBL] [Abstract][Full Text] [Related]  

  • 48. The Effect of Temporary Cement Cleaning Methods on the Retention of Crowns.
    Song MY; An H; Park EJ
    J Prosthodont; 2019 Jan; 28(1):e210-e215. PubMed ID: 28598530
    [TBL] [Abstract][Full Text] [Related]  

  • 49. The influence of different cements on the fracture resistance and marginal adaptation of all-ceramic and fiber-reinforced crowns.
    Behr M; Rosentritt M; Mangelkramer M; Handel G
    Int J Prosthodont; 2003; 16(5):538-42. PubMed ID: 14651242
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Fracture resistance of aluminium oxide and lithium disilicate-based crowns using different luting cements: an in vitro study.
    Al-Wahadni AM; Hussey DL; Grey N; Hatamleh MM
    J Contemp Dent Pract; 2009 Mar; 10(2):51-8. PubMed ID: 19279972
    [TBL] [Abstract][Full Text] [Related]  

  • 51. The fracture load and failure types of veneered anterior zirconia crowns: an analysis of normal and Weibull distribution of complete and censored data.
    Stawarczyk B; Ozcan M; Hämmerle CH; Roos M
    Dent Mater; 2012 May; 28(5):478-87. PubMed ID: 22196897
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Do resin cement viscosity and ceramic surface etching influence the fatigue performance of bonded lithium disilicate glass-ceramic crowns?
    Dapieve KS; Pereira GKR; Venturini AB; Daudt N; Valcanaia A; Bottino MC; Valandro LF
    Dent Mater; 2022 Mar; 38(3):e59-e67. PubMed ID: 34969523
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Influence of preparation, fitting, and cementation on the vitro performance and fracture resistance of CAD/CAM crowns.
    Rosentritt M; Preis V; Behr M; Hahnel S
    J Dent; 2017 Oct; 65():70-75. PubMed ID: 28734997
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Influence of fabrication techniques and artificial aging on the fracture resistance of different cantilever zirconia fixed dental prostheses.
    Ghazy MH; Madina MM; Aboushelib MN
    J Adhes Dent; 2012 Apr; 14(2):161-6. PubMed ID: 21734975
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Zirconia-reinforced lithium silicate crowns: Effect of thickness on survival and failure mode.
    Bergamo ETP; Bordin D; Ramalho IS; Lopes ACO; Gomes RS; Kaizer M; Witek L; Bonfante EA; Coelho PG; Del Bel Cury AA
    Dent Mater; 2019 Jul; 35(7):1007-1016. PubMed ID: 31064670
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Fracture resistance of incisor teeth restored using fibre-reinforced posts and threaded metal posts: effect of post length, location, pretreatment and cementation of the final restoration.
    Schmitter M; Lippenberger S; Rues S; Gilde H; Rammelsberg P
    Int Endod J; 2010 May; 43(5):436-42. PubMed ID: 20518938
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Effect of core thickness differences on post-fatigue indentation fracture resistance of veneered zirconia crowns.
    Alhasanyah A; Vaidyanathan TK; Flinton RJ
    J Prosthodont; 2013 Jul; 22(5):383-90. PubMed ID: 23387466
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Resistance to fracture of two all-ceramic crown materials following endodontic access.
    Wood KC; Berzins DW; Luo Q; Thompson GA; Toth JM; Nagy WW
    J Prosthet Dent; 2006 Jan; 95(1):33-41. PubMed ID: 16399273
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Strength of CAD/CAM-generated esthetic ceramic molar implant crowns.
    Wolf D; Bindl A; Schmidlin PR; Lüthy H; Mörmann WH
    Int J Oral Maxillofac Implants; 2008; 23(4):609-17. PubMed ID: 18807555
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Endodontic Access Effect on Full Contour Zirconia and Lithium Disilicate Failure Resistance.
    Mallya J; DuVall N; Brewster J; Roberts H
    Oper Dent; 2020; 45(3):276-285. PubMed ID: 32053460
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 26.