These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 27895366)

  • 1. Intra-operative implantation errors during Austin Moore Hemiarthroplasty.
    Naqvi ZG; Markhand JA; Ahmed SK; Chinoy A; Khan MA
    J Pak Med Assoc; 2016 Oct; 66(Suppl 3)(10):S90-S92. PubMed ID: 27895366
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Intra-operative implantation errors during hemiarthroplasty.
    Mue D; Yongu W; Mohammad H; Kortor J; Elachi I; Donwa J
    J West Afr Coll Surg; 2012 Oct; 2(4):79-94. PubMed ID: 25453005
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Intra-operative error during Austin Moore hemiarthroplasty.
    Weinrauch P
    J Orthop Surg (Hong Kong); 2006 Dec; 14(3):249-52. PubMed ID: 17200524
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A comparison between Austin-Moore and Corail prosthesis regarding intraoperative periprosthetic femur fractures in hip hemiarthroplasty.
    Mazzawi E; Ghrayeb N; Khury F; Norman D; Keren Y
    Sci Rep; 2022 Apr; 12(1):6340. PubMed ID: 35428861
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Austin-Moore hemiarthroplasty for failed osteosynthesis of intracapsular proximal femoral fractures.
    Roberts C; Parker MJ
    Injury; 2002 Jun; 33(5):423-6. PubMed ID: 12095723
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Survival of patients aged over 80 years after Austin-Moore hemiarthroplasty and bipolar hemiarthroplasty for femoral neck fractures.
    Lin CC; Huang SC; Ou YK; Liu YC; Tsai CM; Chan HH; Wang CT
    Asian J Surg; 2012 Apr; 35(2):62-6. PubMed ID: 22720860
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Austin Moore hemiarthroplasty: technical aspects and their effects on outcome, in patients with fractures of the neck of femur.
    Sharif KM; Parker MJ
    Injury; 2002 Jun; 33(5):419-22. PubMed ID: 12095722
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Incidence of periprosthetic fractures after hip hemiarthroplasty: Are uncemented prostheses unsafe?
    McGraw IW; Spence SC; Baird EJ; Eckhardt SM; Ayana GE
    Injury; 2013 Dec; 44(12):1945-8. PubMed ID: 24001784
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Early prosthetic complications after unipolar hemiarthroplasty.
    Weinrauch PC; Moore WR; Shooter DR; Wilkinson MP; Bonrath EM; Dedy NJ; McMeniman TJ; Jabur MK; Whitehouse SL; Crawford RW
    ANZ J Surg; 2006 Jun; 76(6):432-5. PubMed ID: 16768762
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Results of Conversion from Failed Austin-Moore Hemiarthroplasty to Cementless Total Hip Arthroplasty in Octogenarian Patients with Advanced Acetabular Erosion: A Minimum of 5 Years of Follow-Up.
    Huang TW; Chang CH; Chang FC; Chen CC; Huang KC; Lee MS; Shih HN
    Biomed Res Int; 2019; 2019():7814602. PubMed ID: 31061827
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Outcomes of cerclage wiring to manage intra-operative femoral fracture occurring during cementless hemiarthroplasty in older patients with femoral neck fractures.
    Unnanuntana A; Saiyudthong N
    Int Orthop; 2019 Nov; 43(11):2637-2647. PubMed ID: 30968166
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Periprosthetic fractures around hip hemiarthroplasty performed for hip fracture.
    Phillips JR; Moran CG; Manktelow AR
    Injury; 2013 Jun; 44(6):757-62. PubMed ID: 23103113
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Early result of hemiarthroplasty in elderly patients with fracture neck of femur.
    Daniel M; Mohammed S; Francis A; William Y; Joseph K; Cornilius E
    Niger Med J; 2015; 56(1):64-8. PubMed ID: 25657497
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Uncemented Austin-Moore and cemented Thompson unipolar hemiarthroplasty for displaced fracture neck of femur--comparison of complications and patient satisfaction.
    Singh GK; Deshmukh RG
    Injury; 2006 Feb; 37(2):169-74. PubMed ID: 16413024
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Unusual way of loosened total hip arthroplasty treatment with an Austin Moore endoprosthesis.
    Erceg M; Becic K
    J Postgrad Med; 2014; 60(1):81-3. PubMed ID: 24625947
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Outcomes after early return to theatre following hip hemiarthroplasty for intracapsular fracture of the femoral neck.
    Mamarelis G; Key S; Snook J; Aldam C
    Bone Joint J; 2017 Jul; 99-B(7):958-963. PubMed ID: 28663404
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cemented Bipolar Hemiarthroplasty Provides Definitive Treatment for Femoral Neck Fractures at 20 Years and Beyond.
    von Roth P; Abdel MP; Harmsen WS; Berry DJ
    Clin Orthop Relat Res; 2015 Nov; 473(11):3595-9. PubMed ID: 26186915
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparative study in surgical outcome of intracapsular fracture neck of femur in active elderly patients treated with hemiarthroplasty with Austin Moore's and bipolar prosthesis.
    Mishra AK; Chalise PK; Shah SB; Adhikari V; Singh RP
    Nepal Med Coll J; 2013 Mar; 15(1):81-3. PubMed ID: 24592803
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Historically, did Cemented Thompson perform better than uncemented Austin Moore hemiarthroplasty for femoral neck fractures? A meta-analysis of available evidence.
    Shehata MSA; Abdelal A; Salahia S; Ahmed H; Shawqi M; Elsehili A; Morsi M; Afifi AM; Kader N; Grubhofer F; Sallam A; Imam M
    SICOT J; 2019; 5():33. PubMed ID: 31538934
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Second femur fracture after hemiarthroplasty of the hip: salvage procedure by Partridge bands and long-stemmed prosthesis.
    Buxton RA; Kinninmonth AW; Döhler JR
    Arch Orthop Trauma Surg (1978); 1986; 105(6):375-6. PubMed ID: 3813854
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.