These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

341 related articles for article (PubMed ID: 27896640)

  • 61. Comparison between Ultrasound and Pathologic Status of Axillary Lymph Nodes in Clinically Node-negative Breast Cancer Patients.
    Bailey A; Layne G; Shahan C; Zhang J; Wen S; Radis S; Richmond B; Partin J; Hazard H
    Am Surg; 2015 Sep; 81(9):865-9. PubMed ID: 26350662
    [TBL] [Abstract][Full Text] [Related]  

  • 62. Accuracy of fine-needle aspiration cytology of axillary lymph nodes in breast cancer patients: a study of 115 cases with cytologic-histologic correlation.
    Alkuwari E; Auger M
    Cancer; 2008 Apr; 114(2):89-93. PubMed ID: 18286535
    [TBL] [Abstract][Full Text] [Related]  

  • 63. Role of diffusion-weighted MRI: predicting axillary lymph node metastases in breast cancer.
    Chung J; Youk JH; Kim JA; Gweon HM; Kim EK; Ryu YH; Son EJ
    Acta Radiol; 2014 Oct; 55(8):909-16. PubMed ID: 24234236
    [TBL] [Abstract][Full Text] [Related]  

  • 64. Clinical utility of ultrasound-needle biopsy for preoperative staging of the axilla in invasive breast cancer.
    Houssami N; Diepstraten SC; Cody HS; Turner RM; Sever AR
    Anticancer Res; 2014 Mar; 34(3):1087-97. PubMed ID: 24596347
    [TBL] [Abstract][Full Text] [Related]  

  • 65. False negative results in axillary lymph nodes by ultrasonography and ultrasonography-guided fine-needle aspiration in patients with invasive ductal carcinoma.
    Park SH; Kim EK; Park BW; Kim SI; Moon HJ; Kim MJ
    Ultraschall Med; 2013 Dec; 34(6):559-67. PubMed ID: 23258771
    [TBL] [Abstract][Full Text] [Related]  

  • 66. The roles of
    Nakano Y; Noguchi M; Yokoi-Noguchi M; Ohno Y; Morioka E; Kosaka T; Takahashi T; Minato H
    Breast Cancer; 2017 Jan; 24(1):121-127. PubMed ID: 27015862
    [TBL] [Abstract][Full Text] [Related]  

  • 67. Current applications and future prospects of fine-needle aspiration biopsy of locoregional lymph nodes in the management of breast cancer.
    Krishnamurthy S
    Cancer; 2009 Dec; 117(6):451-62. PubMed ID: 19813277
    [TBL] [Abstract][Full Text] [Related]  

  • 68. Axillary staging by percutaneous biopsy: sensitivity of fine-needle aspiration versus core needle biopsy.
    Rao R; Lilley L; Andrews V; Radford L; Ulissey M
    Ann Surg Oncol; 2009 May; 16(5):1170-5. PubMed ID: 19263171
    [TBL] [Abstract][Full Text] [Related]  

  • 69. Is Pre-Operative Axillary Staging with Ultrasound and Ultrasound-Guided Fine-Needle Aspiration Reliable in Invasive Lobular Carcinoma of the Breast?
    Kim SY; Kim EK; Moon HJ; Yoon JH; Kim MJ
    Ultrasound Med Biol; 2016 Jun; 42(6):1263-72. PubMed ID: 26988417
    [TBL] [Abstract][Full Text] [Related]  

  • 70. Preoperative axillary nodal staging of invasive lobular breast cancer with ultrasound guided fine needle aspiration in patients with suspicious ultrasound findings versus aspiration in all patients - A retrospective single institutional analysis.
    Cserni G; Ambrózay É; Serényi P; Bori R; Sejben I; Csörgő E; Serfőző O; Lóránd K; Venczel L; Maráz R; Sinkó M; Szeleczki N; Nyári T; Zombori T
    Eur J Surg Oncol; 2022 Apr; 48(4):742-747. PubMed ID: 34872778
    [TBL] [Abstract][Full Text] [Related]  

  • 71. Efficiency of ultrasound and ultrasound-guided fine needle aspiration cytology in preoperative assessment of axillary lymph node metastases in breast cancer.
    Oz A; Demirkazik FB; Akpinar MG; Soygur I; Baykal A; Onder SC; Uner A
    J Breast Cancer; 2012 Jun; 15(2):211-7. PubMed ID: 22807939
    [TBL] [Abstract][Full Text] [Related]  

  • 72. Use of axillary ultrasonography in breast cancer: a useful tool to reduce sentinel node procedures.
    Sianesi M; Ceci G; Ghirarduzzi A; Del Rio P; Guazzi A; Pisanelli B; Martella E; Ardizzoni A; Di Blasio B; Arcuri MF
    Ann Ital Chir; 2009; 80(4):315-8. PubMed ID: 19967892
    [TBL] [Abstract][Full Text] [Related]  

  • 73. Diagnostic Yield of Fine-Needle Aspiration for Axillary Lymph Nodes During Screening Breast Ultrasound.
    Youn I; Kim EK; Yoon JH; Moon HJ; Kim MJ
    Ultrasound Q; 2016 Jun; 32(2):144-50. PubMed ID: 27054655
    [TBL] [Abstract][Full Text] [Related]  

  • 74. Redefining ultrasound appearance criteria of positive axillary lymph nodes.
    Duchesne N; Jaffey J; Florack P; Duchesne S
    Can Assoc Radiol J; 2005 Dec; 56(5):289-96. PubMed ID: 16579022
    [TBL] [Abstract][Full Text] [Related]  

  • 75. Accuracy of axillary lymph node staging in breast cancer patients: an observer-performance study comparison of MRI and ultrasound.
    Abe H; Schacht D; Kulkarni K; Shimauchi A; Yamaguchi K; Sennett CA; Jiang Y
    Acad Radiol; 2013 Nov; 20(11):1399-404. PubMed ID: 24119352
    [TBL] [Abstract][Full Text] [Related]  

  • 76. Should axillary ultrasound be used in patients with a preoperative diagnosis of ductal carcinoma in situ?
    Ansari B; Boughey JC; Adamczyk DL; Degnim AC; Jakub JW; Morton MJ
    Am J Surg; 2012 Sep; 204(3):290-3. PubMed ID: 22749764
    [TBL] [Abstract][Full Text] [Related]  

  • 77. Prospective study of ultrasound-guided fine-needle aspiration cytology and sentinel node biopsy in the staging of clinically negative T1 and T2 oral cancer.
    Chaturvedi P; Datta S; Arya S; Rangarajan V; Kane SV; Nair D; Nair S; Chaukar DA; Pai PS; Pantvaidya G; Deshmukh AD; Agrawal A; D'Cruz AK
    Head Neck; 2015 Oct; 37(10):1504-8. PubMed ID: 24890924
    [TBL] [Abstract][Full Text] [Related]  

  • 78. Assessment of multifocality and axillary nodal involvement in early-stage breast cancer patients using 18F-FDG PET/CT compared to contrast-enhanced and diffusion-weighted magnetic resonance imaging and sentinel node biopsy.
    Ergul N; Kadioglu H; Yildiz S; Yucel SB; Gucin Z; Erdogan EB; Aydin M; Muslumanoglu M
    Acta Radiol; 2015 Aug; 56(8):917-23. PubMed ID: 25013091
    [TBL] [Abstract][Full Text] [Related]  

  • 79. The role of preoperative axillary lymph node fine needle aspiration in locoregional staging of breast cancer.
    Sauer T; Suciu V
    Ann Pathol; 2012 Dec; 32(6):e24-8, 410-4. PubMed ID: 23244481
    [TBL] [Abstract][Full Text] [Related]  

  • 80. Preoperative sonographic classification of axillary lymph nodes in patients with breast cancer: node-to-node correlation with surgical histology and sentinel node biopsy results.
    Cho N; Moon WK; Han W; Park IA; Cho J; Noh DY
    AJR Am J Roentgenol; 2009 Dec; 193(6):1731-7. PubMed ID: 19933672
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 18.