3. Diffusional kurtosis imaging (DKI) incorporation into an intravoxel incoherent motion (IVIM) MR model to measure cerebral hypoperfusion induced by hyperventilation challenge in healthy subjects. Pavilla A; Gambarota G; Arrigo A; Mejdoubi M; Duvauferrier R; Saint-Jalmes H MAGMA; 2017 Dec; 30(6):545-554. PubMed ID: 28608327 [TBL] [Abstract][Full Text] [Related]
4. Stroke assessment with intravoxel incoherent motion diffusion-weighted MRI. Suo S; Cao M; Zhu W; Li L; Li J; Shen F; Zu J; Zhou Z; Zhuang Z; Qu J; Chen Z; Xu J NMR Biomed; 2016 Mar; 29(3):320-8. PubMed ID: 26748572 [TBL] [Abstract][Full Text] [Related]
5. Intravoxel incoherent motion diffusion-weighted imaging in the liver: comparison of mono-, bi- and tri-exponential modelling at 3.0-T. Cercueil JP; Petit JM; Nougaret S; Soyer P; Fohlen A; Pierredon-Foulongne MA; Schembri V; Delhom E; Schmidt S; Denys A; Aho S; Guiu B Eur Radiol; 2015 Jun; 25(6):1541-50. PubMed ID: 25527431 [TBL] [Abstract][Full Text] [Related]
6. MRI quantification of diffusion and perfusion in bone marrow by intravoxel incoherent motion (IVIM) and non-negative least square (NNLS) analysis. Marchand AJ; Hitti E; Monge F; Saint-Jalmes H; Guillin R; Duvauferrier R; Gambarota G Magn Reson Imaging; 2014 Nov; 32(9):1091-6. PubMed ID: 25093628 [TBL] [Abstract][Full Text] [Related]
7. Characterization of lower limb muscle activation patterns during walking and running with Intravoxel Incoherent Motion (IVIM) MR perfusion imaging. Jungmann PM; Pfirrmann C; Federau C Magn Reson Imaging; 2019 Nov; 63():12-20. PubMed ID: 31356861 [TBL] [Abstract][Full Text] [Related]
8. Integrated intravoxel incoherent motion tensor and diffusion tensor brain MRI in a single fast acquisition. Dietrich O; Cai M; Tuladhar AM; Jacob MA; Drenthen GS; Jansen JFA; Marques JP; Topalis J; Ingrisch M; Ricke J; de Leeuw FE; Duering M; Backes WH NMR Biomed; 2023 Jul; 36(7):e4905. PubMed ID: 36637237 [TBL] [Abstract][Full Text] [Related]
10. Simulation of intravoxel incoherent perfusion signal using a realistic capillary network of a mouse brain. Van VP; Schmid F; Spinner G; Kozerke S; Federau C NMR Biomed; 2021 Jul; 34(7):e4528. PubMed ID: 33904210 [TBL] [Abstract][Full Text] [Related]
11. Intravoxel incoherent motion diffusion-weighted imaging analysis of diffusion and microperfusion in grading gliomas and comparison with arterial spin labeling for evaluation of tumor perfusion. Shen N; Zhao L; Jiang J; Jiang R; Su C; Zhang S; Tang X; Zhu W J Magn Reson Imaging; 2016 Sep; 44(3):620-32. PubMed ID: 26880230 [TBL] [Abstract][Full Text] [Related]
12. Orientation dependence of microcirculation-induced diffusion signal in anisotropic tissues. Abdullah OM; Gomez AD; Merchant S; Heidinger M; Poelzing S; Hsu EW Magn Reson Med; 2016 Oct; 76(4):1252-62. PubMed ID: 26511215 [TBL] [Abstract][Full Text] [Related]
13. Evidence of the diffusion time dependence of intravoxel incoherent motion in the brain. Wu D; Zhang J Magn Reson Med; 2019 Dec; 82(6):2225-2235. PubMed ID: 31267578 [TBL] [Abstract][Full Text] [Related]
14. Comparison of tri-exponential decay versus bi-exponential decay and full fitting versus segmented fitting for modeling liver intravoxel incoherent motion diffusion MRI. Chevallier O; Zhou N; Cercueil JP; He J; Loffroy R; Wáng YXJ NMR Biomed; 2019 Nov; 32(11):e4155. PubMed ID: 31361366 [TBL] [Abstract][Full Text] [Related]
15. 3T multiparametric MRI of the prostate: Does intravoxel incoherent motion diffusion imaging have a role in the detection and stratification of prostate cancer in the peripheral zone? Valerio M; Zini C; Fierro D; Giura F; Colarieti A; Giuliani A; Laghi A; Catalano C; Panebianco V Eur J Radiol; 2016 Apr; 85(4):790-4. PubMed ID: 26971425 [TBL] [Abstract][Full Text] [Related]
16. Effect of intravoxel incoherent motion on diffusion parameters in normal brain. Vieni C; Ades-Aron B; Conti B; Sigmund EE; Riviello P; Shepherd TM; Lui YW; Novikov DS; Fieremans E Neuroimage; 2020 Jan; 204():116228. PubMed ID: 31580945 [TBL] [Abstract][Full Text] [Related]
17. Statistical assessment of bi-exponential diffusion weighted imaging signal characteristics induced by intravoxel incoherent motion in malignant breast tumors. Yuan J; Wong OL; Lo GG; Chan HH; Wong TT; Cheung PS Quant Imaging Med Surg; 2016 Aug; 6(4):418-429. PubMed ID: 27709078 [TBL] [Abstract][Full Text] [Related]
18. Comparison of perfusion signal acquired by arterial spin labeling-prepared intravoxel incoherent motion (IVIM) MRI and conventional IVIM MRI to unravel the origin of the IVIM signal. Zhang X; Ingo C; Teeuwisse WM; Chen Z; van Osch MJP Magn Reson Med; 2018 Feb; 79(2):723-729. PubMed ID: 28480534 [TBL] [Abstract][Full Text] [Related]
19. Intravoxel incoherent motion diffusion-weighted imaging in head and neck squamous cell carcinoma: assessment of perfusion-related parameters compared to dynamic contrast-enhanced MRI. Fujima N; Yoshida D; Sakashita T; Homma A; Tsukahara A; Tha KK; Kudo K; Shirato H Magn Reson Imaging; 2014 Dec; 32(10):1206-13. PubMed ID: 25131628 [TBL] [Abstract][Full Text] [Related]
20. A Standardized Parameter-Free Algorithm for Combined Intravoxel Incoherent Motion and Diffusion Kurtosis Analysis of Diffusion Imaging Data. Wurnig MC; Kenkel D; Filli L; Boss A Invest Radiol; 2016 Mar; 51(3):203-10. PubMed ID: 26561050 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]