BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

254 related articles for article (PubMed ID: 27908156)

  • 1. Development of a four-axis moving phantom for patient-specific QA of surrogate signal-based tracking IMRT.
    Mukumoto N; Nakamura M; Yamada M; Takahashi K; Akimoto M; Miyabe Y; Yokota K; Kaneko S; Nakamura A; Itasaka S; Matsuo Y; Mizowaki T; Kokubo M; Hiraoka M
    Med Phys; 2016 Dec; 43(12):6364. PubMed ID: 27908156
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Motion as perturbation. II. Development of the method for dosimetric analysis of motion effects with fixed-gantry IMRT.
    Nelms BE; Opp D; Zhang G; Moros E; Feygelman V
    Med Phys; 2014 Jun; 41(6):061704. PubMed ID: 24877799
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Simple quality assurance method of dynamic tumor tracking with the gimbaled linac system using a light field.
    Miura H; Ozawa S; Hayata M; Tsuda S; Yamada K; Nagata Y
    J Appl Clin Med Phys; 2016 Sep; 17(5):177-183. PubMed ID: 27685142
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Geometric and dosimetric accuracy of dynamic tumor-tracking conformal arc irradiation with a gimbaled x-ray head.
    Ono T; Miyabe Y; Yamada M; Shiinoki T; Sawada A; Kaneko S; Monzen H; Mizowaki T; Kokubo M; Hiraoka M
    Med Phys; 2014 Mar; 41(3):031705. PubMed ID: 24593709
    [TBL] [Abstract][Full Text] [Related]  

  • 5. WE-G-213CD-09: Quality Assurance of the Surrogate Signal-Based Dynamic Tumor-Tracking Irradiation with Vero4DRT (MHI-TM2000).
    Mukumoto N; Nakamura M; Sawada A; Suzuki Y; Takahashi K; Miyabe Y; Kaneko S; Mizowaki T; Kokubo M; Hiraoka M
    Med Phys; 2012 Jun; 39(6Part28):3972. PubMed ID: 28519631
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Geometric and dosimetric accuracy of dynamic tumor tracking during volumetric-modulated arc therapy using a gimbal mounted linac.
    Ono T; Miyabe Y; Takahashi K; Akimoto M; Mukumoto N; Ishihara Y; Nakamura M; Mizowaki T; Hiraoka M
    Radiother Oncol; 2018 Oct; 129(1):166-172. PubMed ID: 29137808
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Validation of a pretreatment delivery quality assurance method for the CyberKnife Synchrony system.
    Mastella E; Vigorito S; Rondi E; Piperno G; Ferrari A; Strata E; Rozza D; Jereczek-Fossa BA; Cattani F
    Med Phys; 2016 Aug; 43(8):4565. PubMed ID: 27487873
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dosimetric and radiobiological impact of dose fractionation on respiratory motion induced IMRT delivery errors: a volumetric dose measurement study.
    Duan J; Shen S; Fiveash JB; Popple RA; Brezovich IA
    Med Phys; 2006 May; 33(5):1380-7. PubMed ID: 16752574
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Motion as a perturbation: measurement-guided dose estimates to moving patient voxels during modulated arc deliveries.
    Feygelman V; Stambaugh C; Zhang G; Hunt D; Opp D; Wolf TK; Nelms BE
    Med Phys; 2013 Feb; 40(2):021708. PubMed ID: 23387731
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Impact of sampling interval in training data acquisition on intrafractional predictive accuracy of indirect dynamic tumor-tracking radiotherapy.
    Mukumoto N; Nakamura M; Akimoto M; Miyabe Y; Yokota K; Matsuo Y; Mizowaki T; Hiraoka M
    Med Phys; 2017 Aug; 44(8):3899-3908. PubMed ID: 28513922
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Commissioning and routine quality assurance of the Radixact Synchrony system.
    Goddard L; Jeong K; Tomé WA
    Med Phys; 2022 Feb; 49(2):1181-1195. PubMed ID: 34914846
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Development of a video image-based QA system for the positional accuracy of dynamic tumor tracking irradiation in the Vero4DRT system.
    Ebe K; Sugimoto S; Utsunomiya S; Kagamu H; Aoyama H; Court L; Tokuyama K; Baba R; Ogihara Y; Ichikawa K; Toyama J
    Med Phys; 2015 Aug; 42(8):4745-54. PubMed ID: 26233202
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Real-time tumor tracking: automatic compensation of target motion using the Siemens 160 MLC.
    Tacke MB; Nill S; Krauss A; Oelfke U
    Med Phys; 2010 Feb; 37(2):753-61. PubMed ID: 20229885
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Monte Carlo dose calculation of segmental IMRT delivery to a moving phantom using dynamic MLC and gating log files.
    Oliver M; Staruch R; Gladwish A; Craig J; Chen J; Wong E
    Phys Med Biol; 2008 May; 53(10):N187-96. PubMed ID: 18448873
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Investigation of dosimetric impact of organ motion in static and dynamic conditions for three stereotactic ablative body radiotherapy techniques: 3D conformal radiotherapy, intensity modulated radiation therapy, and volumetric modulated arc therapy by using presage 3D dosimeters.
    Tajaldeen A; Alghamdi S
    Exp Oncol; 2019 Jun; 41(2):153-159. PubMed ID: 31262148
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Patient-specific quality assurance for the delivery of (60)Co intensity modulated radiation therapy subject to a 0.35-T lateral magnetic field.
    Li HH; Rodriguez VL; Green OL; Hu Y; Kashani R; Wooten HO; Yang D; Mutic S
    Int J Radiat Oncol Biol Phys; 2015 Jan; 91(1):65-72. PubMed ID: 25442343
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dosimetric evaluation of breast radiotherapy in a dynamic phantom.
    Menon G; Pudney D; Smith W
    Phys Med Biol; 2011 Dec; 56(23):7405-18. PubMed ID: 22056856
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Management of three-dimensional intrafraction motion through real-time DMLC tracking.
    Sawant A; Venkat R; Srivastava V; Carlson D; Povzner S; Cattell H; Keall P
    Med Phys; 2008 May; 35(5):2050-61. PubMed ID: 18561681
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Moving from gamma passing rates to patient DVH-based QA metrics in pretreatment dose QA.
    Zhen H; Nelms BE; Tome WA
    Med Phys; 2011 Oct; 38(10):5477-89. PubMed ID: 21992366
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Integration of real-time internal electromagnetic position monitoring coupled with dynamic multileaf collimator tracking: an intensity-modulated radiation therapy feasibility study.
    Smith RL; Sawant A; Santanam L; Venkat RB; Newell LJ; Cho BC; Poulsen P; Catell H; Keall PJ; Parikh PJ
    Int J Radiat Oncol Biol Phys; 2009 Jul; 74(3):868-75. PubMed ID: 19394159
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.