BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

192 related articles for article (PubMed ID: 27909129)

  • 1. Metallosis following implantation of magnetically controlled growing rods in the treatment of scoliosis: a case series.
    Teoh KH; von Ruhland C; Evans SL; James SH; Jones A; Howes J; Davies PR; Ahuja S
    Bone Joint J; 2016 Dec; 98-B(12):1662-1667. PubMed ID: 27909129
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Systematic investigation of metallosis associated with magnetically controlled growing rod implantation for early-onset scoliosis.
    Zhang T; Sze KY; Peng ZW; Cheung KMC; Lui YF; Wong YW; Kwan KYH; Cheung JPY
    Bone Joint J; 2020 Oct; 102-B(10):1375-1383. PubMed ID: 32993330
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Implant Complications After Magnetically Controlled Growing Rods for Early Onset Scoliosis: A Multicenter Retrospective Review.
    Choi E; Yaszay B; Mundis G; Hosseini P; Pawelek J; Alanay A; Berk H; Cheung K; Demirkiran G; Ferguson J; Greggi T; Helenius I; La Rosa G; Senkoylu A; Akbarnia BA
    J Pediatr Orthop; 2017 Dec; 37(8):e588-e592. PubMed ID: 27328123
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Quantifying the 'law of diminishing returns' in magnetically controlled growing rods.
    Ahmad A; Subramanian T; Panteliadis P; Wilson-Macdonald J; Rothenfluh DA; Nnadi C
    Bone Joint J; 2017 Dec; 99-B(12):1658-1664. PubMed ID: 29212690
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The Crooked Rod Sign: A New Radiological Sign to Detect Deformed Threads in the Distraction Mechanism of Magnetically Controlled Growing Rods and a Mode of Distraction Failure.
    Cheung JPY; Zhang T; Bow C; Kwan K; Sze KY; Cheung KMC
    Spine (Phila Pa 1976); 2020 Mar; 45(6):E346-E351. PubMed ID: 31574056
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Metallosis is commonly associated with magnetically controlled growing rods; results from an independent multicentre explant database.
    Rushton PRP; Smith SL; Fender D; Bowey AJ; Gibson MJ; Joyce TJ
    Eur Spine J; 2021 Jul; 30(7):1905-1911. PubMed ID: 33544222
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Analysing a mechanism of failure in retrieved magnetically controlled spinal rods.
    Panagiotopoulou VC; Tucker SK; Whittaker RK; Hothi HS; Henckel J; Leong JJH; Ember T; Skinner JA; Hart AJ
    Eur Spine J; 2017 Jun; 26(6):1699-1710. PubMed ID: 28102447
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Traditional growing rod versus magnetically controlled growing rod for treatment of early onset scoliosis: Cost analysis from implantation till skeletal maturity.
    Wong CKH; Cheung JPY; Cheung PWH; Lam CLK; Cheung KMC
    J Orthop Surg (Hong Kong); 2017; 25(2):2309499017705022. PubMed ID: 28481128
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Magnetic controlled growing rods for early-onset scoliosis: a 4-year follow-up.
    Teoh KH; Winson DM; James SH; Jones A; Howes J; Davies PR; Ahuja S
    Spine J; 2016 Apr; 16(4 Suppl):S34-9. PubMed ID: 26844638
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Analysis of Explanted Magnetically Controlled Growing Rods From Seven UK Spinal Centers.
    Joyce TJ; Smith SL; Rushton PRP; Bowey AJ; Gibson MJ
    Spine (Phila Pa 1976); 2018 Jan; 43(1):E16-E22. PubMed ID: 28459777
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Is rod diameter associated with the rate of rod fracture in patients treated with magnetically controlled growing rods?
    Roye BD; Marciano G; Matsumoto H; Fields MW; Campbell M; White KK; Sawyer J; Smith JT; Luhmann S; Sturm P; Sponseller P; Vitale MG; ;
    Spine Deform; 2020 Dec; 8(6):1375-1384. PubMed ID: 32562099
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Magnetically controlled growing rods in the treatment of early-onset scoliosis: a note of caution.
    Rushton PRP; Siddique I; Crawford R; Birch N; Gibson MJ; Hutton MJ
    Bone Joint J; 2017 Jun; 99-B(6):708-713. PubMed ID: 28566388
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Implant Failure of Titanium Versus Cobalt-Chromium Growing Rods in Early-onset Scoliosis.
    Shinohara K; Takigawa T; Tanaka M; Sugimoto Y; Arataki S; Yamane K; Watanabe N; Ozaki T; Sarai T
    Spine (Phila Pa 1976); 2016 Mar; 41(6):502-7. PubMed ID: 26966974
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The use of magnetically-controlled growing rods to treat children with early-onset scoliosis: early radiological results in 19 children.
    Thompson W; Thakar C; Rolton DJ; Wilson-MacDonald J; Nnadi C
    Bone Joint J; 2016 Sep; 98-B(9):1240-7. PubMed ID: 27587527
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Unplanned Reoperations in Magnetically Controlled Growing Rod Surgery for Early Onset Scoliosis With a Minimum of Two-Year Follow-Up.
    Kwan KYH; Alanay A; Yazici M; Demirkiran G; Helenius I; Nnadi C; Ferguson J; Akbarnia BA; Cheung JPY; Cheung KMC
    Spine (Phila Pa 1976); 2017 Dec; 42(24):E1410-E1414. PubMed ID: 28658035
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The impact of revision of one or more rods on refracture rate and implant survival following rod fracture in instrumentation without fusion constructs in the management of early-onset scoliosis.
    David M; Gardner A; Jennison T; Spilsbury J; Marks D
    J Pediatr Orthop B; 2014 May; 23(3):288-90. PubMed ID: 24487951
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An NIHR-approved two-year observational study on magnetically controlled growth rods in the treatment of early onset scoliosis.
    Nnadi C; Thakar C; Wilson-MacDonald J; Milner P; Rao A; Mayers D; Fairbank J; Subramanian T
    Bone Joint J; 2018 Apr; 100-B(4):507-515. PubMed ID: 29629587
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Metal Ion Release During Growth-Friendly Instrumentation for Early-Onset Scoliosis: A Preliminary Study.
    Yilgor C; Efendiyev A; Akbiyik F; Demirkiran G; Senkoylu A; Alanay A; Yazici M
    Spine Deform; 2018 Jan; 6(1):48-53. PubMed ID: 29287817
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Growing rod fractures: risk factors and opportunities for prevention.
    Yang JS; Sponseller PD; Thompson GH; Akbarnia BA; Emans JB; Yazici M; Skaggs DL; Shah SA; Salari P; Poe-Kochert C;
    Spine (Phila Pa 1976); 2011 Sep; 36(20):1639-44. PubMed ID: 21738096
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Magnetically controlled growing rod in early onset scoliosis: a 30-case multicenter study.
    Lebon J; Batailler C; Wargny M; Choufani E; Violas P; Fron D; Kieffer J; Accadbled F; Cunin V; De Gauzy JS
    Eur Spine J; 2017 Jun; 26(6):1567-1576. PubMed ID: 28040873
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.