BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

406 related articles for article (PubMed ID: 27909867)

  • 1. Developmental validation of the HomyGene19+14Y System.
    Du W; Chen L; Liu H; Qiu P; Li F; Gao J; Zhou Y; Wang B; Liu C
    Int J Legal Med; 2017 May; 131(3):605-620. PubMed ID: 27909867
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Developmental validation of the EX20+4 system.
    Li S; Liu C; Liu H; Ge J; Budowle B; Liu C; Zheng W; Li F; Ge B
    Forensic Sci Int Genet; 2014 Jul; 11():207-13. PubMed ID: 24815370
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Validation of a multiplex amplification system of 19 autosomal STRs and 27 Y-STRs.
    Liu F; Jia F; Sun F; Zhao B; Shen H
    Forensic Sci Res; 2019 Nov; 5(4):292-299. PubMed ID: 33457047
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of population variation at 17 autosomal STR and 16 Y-STR haplotype loci in Croatians.
    Haliti N; Carapina M; Masić M; Strinović D; Klarić IM; Kubat M
    Forensic Sci Int Genet; 2009 Sep; 3(4):e137-8. PubMed ID: 19647700
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Developmental validation of a 6-dye STR kit with 27 loci.
    Li S; Chen L; Wang Y; Xu Q; Liu H; Li Y; Liu C
    Int J Legal Med; 2018 Mar; 132(2):335-342. PubMed ID: 28405751
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development and validation of a new STR 25-plex typing system.
    Zhang S; Bian Y; Tian H; Wang Z; Hu Z; Li C
    Forensic Sci Int Genet; 2015 Jul; 17():61-69. PubMed ID: 25828368
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Development of new PCR multiplex system by the simultaneous detection of 10 miniSTRs, SE33, Penta E, Penta D, and four Y-STRs.
    Shafique M; Shahzad MS; Rahman Z; Shan MA; Perveen R; Shahzad M; Hussain M; Shahid AA; Husnain T
    Int J Legal Med; 2016 Nov; 130(6):1409-1419. PubMed ID: 27166705
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Validation study of a 15-plex rapid STR amplification system for human identification.
    Han J; Sun J; Zhao L; Zhao W; Liu Y; Li C
    Forensic Sci Int Genet; 2017 May; 28():71-81. PubMed ID: 28189975
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Technical note: developmental validation of a novel 6-dye typing system with 36 Y-STR loci.
    Du W; Feng P; Huang H; Wu W; Zhang L; Guo Y; Liu C; Liu H; Liu C; Chen L
    Int J Legal Med; 2019 Jul; 133(4):1015-1027. PubMed ID: 29846776
    [TBL] [Abstract][Full Text] [Related]  

  • 10. STR genetic diversity in a Mediterranean population from the south of the Iberian Peninsula.
    Gaibar M; Esteban E; Moral P; Gómez-Gallego F; Santiago C; Bandrés F; Luna F; Fernández-Santander A
    Ann Hum Biol; 2010 Apr; 37(2):253-66. PubMed ID: 19961347
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of a six-dye multiplex composed of 27 markers for forensic analysis and databasing.
    Wang S; Song F; Xie M; Zhang K; Xie B; Huang Z; Luo H
    Mol Genet Genomic Med; 2020 Sep; 8(9):e1419. PubMed ID: 32677357
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Development of a new 26plex Y-STRs typing system for forensic application.
    Zhang S; Tian H; Wang Z; Zhao S; Hu Z; Li C; Ji C
    Forensic Sci Int Genet; 2014 Nov; 13():112-20. PubMed ID: 25086414
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Developmental validation of the PowerPlex(®) 21 System.
    Ensenberger MG; Hill CR; McLaren RS; Sprecher CJ; Storts DR
    Forensic Sci Int Genet; 2014 Mar; 9():169-78. PubMed ID: 24528595
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Validation of the Microreader 40Y ID System: a Y-STR multiplex for casework and database samples.
    Liu Y; Lv M; Bai P; Wang L; Tan Y; Jian H; Zhang R; Zhu J; Qu S; Luo S; Jiang L; Nie H; Guo D; Yu Z; Li Y; Liang W
    Int J Legal Med; 2021 Jan; 135(1):23-41. PubMed ID: 32519012
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development and validation of a forensic six-dye multiplex assay with 29 STR loci.
    Qu Y; Tao R; Yu H; Yang Q; Wang Z; Tan R; Zhang X; Xia R; Xiong L; Xi S; Wu J; Gao Y; Zhang S; Li C
    Electrophoresis; 2021 Aug; 42(14-15):1419-1430. PubMed ID: 33864289
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Developmental validation of the Yfiler(®) Plus PCR Amplification Kit: An enhanced Y-STR multiplex for casework and database applications.
    Gopinath S; Zhong C; Nguyen V; Ge J; Lagacé RE; Short ML; Mulero JJ
    Forensic Sci Int Genet; 2016 Sep; 24():164-175. PubMed ID: 27459350
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Validation of the Microreader 28A ID System: A 6-dye multiplex amplification assay for forensic application.
    Yin L; Zhu J; Qu S; Li Y; Liu Y; Yu Z; Yang F; Zhang R; Xue J; Huang S; Liang W
    Electrophoresis; 2021 Oct; 42(19):1928-1935. PubMed ID: 34369612
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Developmental validation of the STRscan-17LC kit: a 6 Dye STR kit enhanced stability and ability to detect degraded samples.
    Jiang B; He W; Jin C; Liu Y; Wen D; Wang C; Zeye MMJ; Li J; Zha L
    Int J Legal Med; 2021 Mar; 135(2):431-440. PubMed ID: 33454809
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of the AGCU Expressmarker 30 Kit composed of 31 loci for forensic application.
    Zhang K; Song F; Wang S; Wei X; Gu H; Xie M; Zhou Y; Luo H
    Forensic Sci Int; 2021 Jul; 324():110849. PubMed ID: 34030000
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Technical note: developmental validation of a novel 41-plex Y-STR system for the direct amplification of reference samples.
    Fan G; Pan L; Tang P; Zhou Y; Liu M; Luo X
    Int J Legal Med; 2021 Mar; 135(2):409-419. PubMed ID: 32524192
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 21.