These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 27910652)

  • 1. Measurement and models of bent KAP(001) crystal integrated reflectivity and resolution (invited).
    Loisel GP; Wu M; Stolte W; Kruschwitz C; Lake P; Dunham GS; Bailey JE; Rochau GA
    Rev Sci Instrum; 2016 Nov; 87(11):11D502. PubMed ID: 27910652
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Diffraction properties of cylindrically bent KAP crystals in energy range of 2.3-7.5  keV using synchrotron radiation.
    Wu M; Kruschwitz CA; Lake P; Loisel GP; Bailey JE; Stolte WC
    Appl Opt; 2021 Jan; 60(3):558-570. PubMed ID: 33690429
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measuring and predicting the diffraction properties of cylindrically bent potassium acid phthalate, KAP(001), crystals.
    Haugh MJ; Jacoby KD
    Rev Sci Instrum; 2017 Feb; 88(2):023113. PubMed ID: 28249466
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measuring the x-ray resolving power of bent potassium acid phthalate diffraction crystals.
    Haugh MJ; Wu M; Jacoby KD; Loisel GP
    Rev Sci Instrum; 2014 Nov; 85(11):11D619. PubMed ID: 25430195
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Efficiency calibrations of cylindrically bent transmission crystals in the 20 to 80 keV x-ray energy range.
    Szabo CI; Feldman U; Seltzer S; Hudson LT; O'Brien M; Park HS; Seely JF
    Opt Lett; 2011 Apr; 36(8):1335-7. PubMed ID: 21499348
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A lamellar model for the X-ray rocking curves of sagittally bent Laue crystals.
    Zhong Z; Kao CC; Siddons DP; Zhong H; Hastings JB
    Acta Crystallogr A; 2003 Jan; 59(Pt 1):1-6. PubMed ID: 12496454
    [TBL] [Abstract][Full Text] [Related]  

  • 7. High efficiency, high quality x-ray optic based on ellipsoidally bent highly oriented pyrolytic graphite crystal for ultrafast x-ray diffraction experiments.
    Uschmann I; Nothelle U; Förster E; Arkadiev V; Langhoff N; Antonov A; Grigorieva I; Steinkopf R; Gebhardt A
    Appl Opt; 2005 Aug; 44(24):5069-75. PubMed ID: 16121791
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A technique for measuring the quality of an elliptically bent pentaerythritol [PET(002)] crystal.
    Haugh MJ; Jacoby KD; Barrios MA; Thorn D; Emig JA; Schneider MB
    Rev Sci Instrum; 2016 Nov; 87(11):11D612. PubMed ID: 27910647
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Surface-treated self-standing curved crystals as high-efficiency elements for X- and γ-ray optics: theory and experiment.
    Bonnini E; Buffagni E; Zappettini A; Doyle S; Ferrari C
    J Appl Crystallogr; 2015 Jun; 48(Pt 3):666-671. PubMed ID: 26089758
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Detailed diffraction imaging of x-ray optics crystals with synchrotron radiation.
    Pereira NR; Macrander AT; Kasman E; Huang XR; Baronova EO
    Rev Sci Instrum; 2021 Jun; 92(6):063506. PubMed ID: 34243570
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A compact multi-plane broadband (0.5-17 keV) spectrometer using a single acid phthalate crystal.
    Loisel GP; Lake PW; Nielsen-Weber LB; Wu M; Dunham GS; Bailey JE; Rochau GA
    Rev Sci Instrum; 2018 Oct; 89(10):10F117. PubMed ID: 30399839
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Performance calculations of the X-ray powder diffraction beamline at NSLS-II.
    Shi X; Ghose S; Dooryhee E
    J Synchrotron Radiat; 2013 Mar; 20(Pt 2):234-42. PubMed ID: 23412479
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Integrated x-ray reflectivity measurements of elliptically curved pentaerythritol crystals.
    Haugh MJ; Regan SP; Jacoby KD; Ross PW; Magoon J; Barrios MA; Emig JA; Shoup MJ; Fournier KB
    Rev Sci Instrum; 2012 Oct; 83(10):10E122. PubMed ID: 23126944
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Topography of bent crystals with microradian resolution in one dimension.
    Pereira NR; Macrander AT; Harding EC
    Rev Sci Instrum; 2022 Nov; 93(11):113538. PubMed ID: 36461482
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Characterization and on-line adjustment of the sagittal-bent Laue crystal profile.
    Dong W; Cai Q; Yang F; Liu X; Yang J; Diao Q; Liu P; Zhang X; Hu L
    J Synchrotron Radiat; 2018 Sep; 25(Pt 5):1346-1353. PubMed ID: 30179172
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Microfocusing of hard X-rays with cylindrically bent crystal monochromators.
    Schulze C; Lienert U; Hanfland M; Lorenzen M; Zontone F
    J Synchrotron Radiat; 1998 Mar; 5(Pt 2):77-81. PubMed ID: 16687807
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Rocking-curve width of sagittally bent Laue crystals.
    Zhong Z; Kao CC; Siddons DP; Hastings JB
    Acta Crystallogr A; 2002 Sep; 58(Pt 5):487-93. PubMed ID: 12192122
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Focusing and reflection by a bent crystal for high-energy synchrotron radiation.
    Yamaoka H; Ohtomo K; Ishikawa T
    J Synchrotron Radiat; 1998 May; 5(Pt 3):687-9. PubMed ID: 15263620
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Ray tracing flux calculation for the small and wide angle x-ray scattering diffraction station at the SESAME synchrotron radiation facility.
    Salah W; del Rio MS; Hoorani H
    Rev Sci Instrum; 2009 Sep; 80(9):095106. PubMed ID: 19791963
    [TBL] [Abstract][Full Text] [Related]  

  • 20. X-ray Optics of a Dynamical Sagittal-Focusing Monochromator on the GILDA Beamline at the ESRF.
    Pascarelli S; Boscherini F; D'Acapito F; Hrdy J; Meneghini C; Mobilio S
    J Synchrotron Radiat; 1996 Jul; 3(Pt 4):147-55. PubMed ID: 16702672
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.