These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
81 related articles for article (PubMed ID: 2791391)
1. Analysis of the pull-out strength of screws and pegs used to secure tibial components following total knee arthroplasty. Finlay JB; Harada I; Bourne RB; Rorabeck CH; Hardie R; Scott MA Clin Orthop Relat Res; 1989 Oct; (247):220-31. PubMed ID: 2791391 [TBL] [Abstract][Full Text] [Related]
2. Screw pull-out force is dependent on screw orientation in an anterior cervical plate construct. DiPaola CP; Jacobson JA; Awad H; Conrad BP; Rechtine GR J Spinal Disord Tech; 2007 Jul; 20(5):369-73. PubMed ID: 17607102 [TBL] [Abstract][Full Text] [Related]
3. Effects of bone materials on the screw pull-out strength in human spine. Zhang QH; Tan SH; Chou SM Med Eng Phys; 2006 Oct; 28(8):795-801. PubMed ID: 16414303 [TBL] [Abstract][Full Text] [Related]
4. Mechanical performance of standard and cannulated 4.0-mm cancellous bone screws. Brown GA; McCarthy T; Bourgeault CA; Callahan DJ J Orthop Res; 2000 Mar; 18(2):307-12. PubMed ID: 10815833 [TBL] [Abstract][Full Text] [Related]
5. Fine thread versus coarse thread. A comparison of the maximum holding power. Gausepohl T; Möhring R; Pennig D; Koebke J Injury; 2001 Dec; 32 Suppl 4():SD1-7. PubMed ID: 11812471 [TBL] [Abstract][Full Text] [Related]
6. Investigation of fixation screw pull-out strength on human spine. Zhang QH; Tan SH; Chou SM J Biomech; 2004 Apr; 37(4):479-85. PubMed ID: 14996559 [TBL] [Abstract][Full Text] [Related]
7. The effect of repetitive pilot-hole use on the insertion torque and pullout strength of vertebral system screws. Defino HL; Rosa RC; Silva P; Shimano AC; Volpon JB; de Paula FJ; Schleicher P; Schnake K; Kandziora F Spine (Phila Pa 1976); 2009 Apr; 34(9):871-6. PubMed ID: 19531995 [TBL] [Abstract][Full Text] [Related]
8. Comparison of pull out strength of resorbable screws in human cadaveric laryngeal cartilage using different drill diameters. Lewis AF; Jordan JR; Parsell DE; Kosko M Head Neck; 2008 Nov; 30(11):1464-8. PubMed ID: 18642318 [TBL] [Abstract][Full Text] [Related]
9. Stress relaxation of bone significantly affects the pull-out behavior of pedicle screws. Inceoglu S; McLain RF; Cayli S; Kilincer C; Ferrara L J Orthop Res; 2004 Nov; 22(6):1243-7. PubMed ID: 15475204 [TBL] [Abstract][Full Text] [Related]
10. [Comparison of the pull-out strengths of three different screws in pedicular screw revisions: a biomechanical study]. Esenkaya I; Denizhan Y; Kaygusuz MA; Yetmez M; Keleştemur MH Acta Orthop Traumatol Turc; 2006; 40(1):72-81. PubMed ID: 16648682 [TBL] [Abstract][Full Text] [Related]
11. A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. Zindrick MR; Wiltse LL; Widell EH; Thomas JC; Holland WR; Field BT; Spencer CW Clin Orthop Relat Res; 1986 Feb; (203):99-112. PubMed ID: 3956001 [TBL] [Abstract][Full Text] [Related]
12. Hydroxyapatite-coating of pedicle screws improves resistance against pull-out force in the osteoporotic canine lumbar spine model: a pilot study. Hasegawa T; Inufusa A; Imai Y; Mikawa Y; Lim TH; An HS Spine J; 2005; 5(3):239-43. PubMed ID: 15863077 [TBL] [Abstract][Full Text] [Related]
13. Influence of peg design and cement mantle thickness on pull-out strength of glenoid component pegs. Nyffeler RW; Anglin C; Sheikh R; Gerber C J Bone Joint Surg Br; 2003 Jul; 85(5):748-52. PubMed ID: 12892204 [TBL] [Abstract][Full Text] [Related]
14. Proximal half angle of the screw thread is a critical design variable affecting the pull-out strength of cancellous bone screws. Wang Y; Mori R; Ozoe N; Nakai T; Uchio Y Clin Biomech (Bristol); 2009 Nov; 24(9):781-5. PubMed ID: 19699567 [TBL] [Abstract][Full Text] [Related]
15. Fixation pull-out response measurement of bone screws and porous-surfaced posts. Shirazi-Adl A; Dammak M; Zukor DJ J Biomech; 1994 Oct; 27(10):1249-58. PubMed ID: 7962012 [TBL] [Abstract][Full Text] [Related]
16. The fixation strength of scaphoid bone screws: an in vitro investigation using polyurethane foam. Crawford LA; Powell ES; Trail IA J Hand Surg Am; 2012 Feb; 37(2):255-60. PubMed ID: 22154719 [TBL] [Abstract][Full Text] [Related]
17. A biomechanical study comparing a raft of 3.5 mm cortical screws with 6.5 mm cancellous screws in depressed tibial plateau fractures. Patil S; Mahon A; Green S; McMurtry I; Port A Knee; 2006 Jun; 13(3):231-5. PubMed ID: 16647262 [TBL] [Abstract][Full Text] [Related]
18. Mechanical tests and finite element models for bone holding power of tibial locking screws. Hou SM; Hsu CC; Wang JL; Chao CK; Lin J Clin Biomech (Bristol); 2004 Aug; 19(7):738-45. PubMed ID: 15288461 [TBL] [Abstract][Full Text] [Related]
19. Biomechanical comparison of anatomic trajectory pedicle screw versus injectable calcium sulfate graft-augmented pedicle screw for salvage in cadaveric thoracic bone. Derincek A; Wu C; Mehbod A; Transfeldt EE J Spinal Disord Tech; 2006 Jun; 19(4):286-91. PubMed ID: 16778665 [TBL] [Abstract][Full Text] [Related]
20. Laboratory testing of bolts and screws in cancellous bone. Pratt WB; Yazdani S Orthop Rev; 1989 Oct; 18(10):1073-7. PubMed ID: 2608304 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]