These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 27917580)

  • 1. A combined registration and finite element analysis method for fast estimation of intraoperative brain shift; phantom and animal model study.
    Mohammadi A; Ahmadian A; Rabbani S; Fattahi E; Shirani S
    Int J Med Robot; 2017 Dec; 13(4):. PubMed ID: 27917580
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Estimation of intraoperative brain shift by combination of stereovision and doppler ultrasound: phantom and animal model study.
    Mohammadi A; Ahmadian A; Azar AD; Sheykh AD; Amiri F; Alirezaie J
    Int J Comput Assist Radiol Surg; 2015 Nov; 10(11):1753-64. PubMed ID: 25958061
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accuracy of finite element model-based multi-organ deformable image registration.
    Brock KK; Sharpe MB; Dawson LA; Kim SM; Jaffray DA
    Med Phys; 2005 Jun; 32(6):1647-59. PubMed ID: 16013724
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fast and adaptive finite element approach for modeling brain shift.
    Soza G; Grosso R; Labsik U; Nimsky C; Fahlbusch R; Greiner G; Hastreiter P
    Comput Aided Surg; 2003; 8(5):241-6. PubMed ID: 15529953
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Registration of 3-D intraoperative MR images of the brain using a finite-element biomechanical model.
    Ferrant M; Nabavi A; Macq B; Jolesz FA; Kikinis R; Warfield SK
    IEEE Trans Med Imaging; 2001 Dec; 20(12):1384-97. PubMed ID: 11811838
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Physical Constraint Finite Element Model for Medical Image Registration.
    Zhang J; Wang J; Wang X; Gao X; Feng D
    PLoS One; 2015; 10(10):e0140567. PubMed ID: 26495841
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Model-Based Deformable Registration of Preoperative 3D to Intraoperative Low-Resolution 3D and 2D Sequences of MR Images.
    Marami B; Sirouspour S; Capson DW
    Med Image Comput Comput Assist Interv; 2011; 14(Pt 1):460-7. PubMed ID: 22003650
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A fast and robust patient specific Finite Element mesh registration technique: application to 60 clinical cases.
    Bucki M; Lobos C; Payan Y
    Med Image Anal; 2010 Jun; 14(3):303-17. PubMed ID: 20299273
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Automated finite-element analysis for deformable registration of prostate images.
    Crouch JR; Pizer SM; Chaney EL; Hu YC; Mageras GS; Zaider M
    IEEE Trans Med Imaging; 2007 Oct; 26(10):1379-90. PubMed ID: 17948728
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Physics-based shape matching for intraoperative image guidance.
    Suwelack S; Röhl S; Bodenstedt S; Reichard D; Dillmann R; dos Santos T; Maier-Hein L; Wagner M; Wünscher J; Kenngott H; Müller BP; Speidel S
    Med Phys; 2014 Nov; 41(11):111901. PubMed ID: 25370634
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Extended finite element method with simplified spherical harmonics approximation for the forward model of optical molecular imaging.
    Li W; Yi H; Zhang Q; Chen D; Liang J
    Comput Math Methods Med; 2012; 2012():394374. PubMed ID: 23227108
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Patient-specific model of brain deformation: application to medical image registration.
    Wittek A; Miller K; Kikinis R; Warfield SK
    J Biomech; 2007; 40(4):919-29. PubMed ID: 16678834
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fast computation of soft tissue thermal response under deformation based on fast explicit dynamics finite element algorithm for surgical simulation.
    Zhang J; Chauhan S
    Comput Methods Programs Biomed; 2020 Apr; 187():105244. PubMed ID: 31805458
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Three-dimensional quantification of vorticity and helicity from 3D cine PC-MRI using finite-element interpolations.
    Sotelo J; Urbina J; Valverde I; Mura J; Tejos C; Irarrazaval P; Andia ME; Hurtado DE; Uribe S
    Magn Reson Med; 2018 Jan; 79(1):541-553. PubMed ID: 28370386
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A hybrid reconstruction algorithm for fluorescence tomography using Kirchhoff approximation and finite element method.
    Wang X; Cao X; Zhang B; Liu F; Luo J; Bai J
    Med Biol Eng Comput; 2013 Feb; 51(1-2):7-17. PubMed ID: 23203683
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A convenient scheme for coupling a finite element curvilinear mesh to a finite element voxel mesh: application to the heart.
    Hopenfeld B
    Biomed Eng Online; 2006 Nov; 5():60. PubMed ID: 17112373
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intraoperative brain shift prediction using a 3D inhomogeneous patient-specific finite element model.
    Hu J; Jin X; Lee JB; Zhang L; Chaudhary V; Guthikonda M; Yang KH; King AI
    J Neurosurg; 2007 Jan; 106(1):164-9. PubMed ID: 17236503
    [TBL] [Abstract][Full Text] [Related]  

  • 18. GPU-based acceleration of computations in nonlinear finite element deformation analysis.
    Mafi R; Sirouspour S
    Int J Numer Method Biomed Eng; 2014 Mar; 30(3):365-81. PubMed ID: 24166875
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Robust nonrigid registration to capture brain shift from intraoperative MRI.
    Clatz O; Delingette H; Talos IF; Golby AJ; Kikinis R; Jolesz FA; Ayache N; Warfield SK
    IEEE Trans Med Imaging; 2005 Nov; 24(11):1417-27. PubMed ID: 16279079
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Reducing uncertainties in volumetric image based deformable organ registration.
    Liang J; Yan D
    Med Phys; 2003 Aug; 30(8):2116-22. PubMed ID: 12945976
    [TBL] [Abstract][Full Text] [Related]  