These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 279193)

  • 1. Transcutaneous blood gas measurement using a mass spectrometer.
    McIlroy MB; Simbruner G; Sonoda Y
    Acta Anaesthesiol Scand Suppl; 1978; 68():128-30. PubMed ID: 279193
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Trancutaneous blood gas measurement by mass spectrometry.
    Parker D; Delpy D; Reynolds EO
    Acta Anaesthesiol Scand Suppl; 1978; 68():131-6. PubMed ID: 279194
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Quadrupole mass filtering for registration of blood gas partial pressures.
    Beste KW; Duchanova H; Hellige G; Prennschütz-Schützenau H; Vennebusch H; Bretschneider HJ
    Pflugers Arch; 1976 Sep; 365(2-3):249-55. PubMed ID: 988565
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Measurement of blood-gas partial pressures in vivo with a mass spectrometer probe in a vessel with blood-flow].
    Beste KW; Hellige G; Hensel I; Schenk HD; Bretschneider HJ
    Biomed Tech (Berl); 1976 Apr; 21(3):86-91. PubMed ID: 1268304
    [No Abstract]   [Full Text] [Related]  

  • 5. The importance of an elevated skin temperature in transcutaneous oxygen tension measurement.
    Al-Siaidy W; Hill DW
    Birth Defects Orig Artic Ser; 1979; 15(4):149-65. PubMed ID: 534695
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Measuring oxygen uptake and carbon dioxide production in critically ill patients using a standard blood gas analyzer.
    Zenger M; Brenner M; Hua P; Haruno M; Wilson AF
    Crit Care Med; 1994 May; 22(5):783-8. PubMed ID: 8181286
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Use of transcutaneous oxygen and carbon dioxide tensions for assessing indices of gas exchange during exercise testing.
    Carter R; Banham SW
    Respir Med; 2000 Apr; 94(4):350-5. PubMed ID: 10845433
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Transcutaneous measurement of arterial blood-gas tensions by mass spectrometry.
    Delpy D; Parker D
    Lancet; 1975 May; 1(7914):1016. PubMed ID: 48678
    [No Abstract]   [Full Text] [Related]  

  • 9. A method for the in vitro measurement of tensions of blood gases with a mass spectrometer.
    Matalon S; Erickson J; Mosharrafa M; Leonard AS
    Med Instrum; 1975; 9(3):133-5. PubMed ID: 1128321
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Continuous transcutaneous oxygen and carbon dioxide monitoring in the pediatric ICU.
    Monaco F; Nickerson BG; McQuitty JC
    Crit Care Med; 1982 Nov; 10(11):765-6. PubMed ID: 6814823
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Skin gas tensions and resistances measured by mass spectrometry in adults.
    Targett RC; Kocher O; Muramatsu K; McIlroy MB
    J Appl Physiol Respir Environ Exerc Physiol; 1984 May; 56(5):1431-5. PubMed ID: 6427157
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Improvement of response on transcutaneous gas tension measurement by mass spectrometry (author's transl)].
    Watanabe Y; Yamamoto K; Mikami T
    Iyodenshi To Seitai Kogaku; 1981 Jun; 19(3):210-5. PubMed ID: 6799677
    [No Abstract]   [Full Text] [Related]  

  • 13. Transfer of oxygen, nitrogen, and carbon dioxide through normal adult human skin.
    Hansen TN; Sonoda Y; McIlroy MB
    J Appl Physiol Respir Environ Exerc Physiol; 1980 Sep; 49(3):438-43. PubMed ID: 6782048
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Single electrochemical sensor for transcutaneous measurement of PO2 and PCO2.
    Parker D; Delpy DT; Reynolds EO
    Birth Defects Orig Artic Ser; 1979; 15(4):109-16. PubMed ID: 534689
    [No Abstract]   [Full Text] [Related]  

  • 15. Continuous measurement of blood gases in vivo by mass spectrometry.
    Foëx P; Burt G; Maynard P; Ryder WA; Hahn CE
    Br J Anaesth; 1979 Nov; 51(11):999-1005. PubMed ID: 518813
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Transcutaneous carbon dioxide and oxygen tension measured at different temperatures in healthy adults.
    Wimberley PD; Grønlund Pedersen K; Olsson J; Siggaard-Andersen O
    Clin Chem; 1985 Oct; 31(10):1611-5. PubMed ID: 3930089
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transcutaneous monitoring of blood gases: is it comparable with arterialized earlobe sampling?
    Dawson S; Cave C; Pavord I; Potter JF
    Respir Med; 1998 Mar; 92(3):584-7. PubMed ID: 9692127
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Changes in arterial and transcutaneous oxygen and carbon dioxide tensions during and after voluntary hyperventilation.
    Steurer J; Hoffmann U; Dür P; Russi E; Vetter W
    Respiration; 1997; 64(3):200-5. PubMed ID: 9154671
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Techniques for measuring the partial pressures of gases in the blood. Part I--in vitro measurements.
    Hahn CE
    J Phys E; 1980 May; 13(5):470-82. PubMed ID: 6768877
    [No Abstract]   [Full Text] [Related]  

  • 20. Arterial blood gas tensions and pH.
    Flenley DC
    Br J Clin Pharmacol; 1980 Feb; 9(2):129-35. PubMed ID: 7356899
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.