These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

86 related articles for article (PubMed ID: 27923795)

  • 1. Johnson & Johnson is ordered to pay $1bn over faulty hip implants.
    Dyer O
    BMJ; 2016 Dec; 355():i6551. PubMed ID: 27923795
    [No Abstract]   [Full Text] [Related]  

  • 2. High Court will hear class action against metal-on-metal hip manufacturer.
    Dyer C
    BMJ; 2017 Oct; 359():j4711. PubMed ID: 29021201
    [No Abstract]   [Full Text] [Related]  

  • 3. Bilateral total hip replacement: periprosthetic pseudotumor collections are more prevalent in metal-on-metal implants compared to non-metal-on-metal ones.
    Slonimsky E; Kushnir T; Kadar A; Menahem A; Grundshtein A; Dekel S; Eshed I
    Acta Radiol; 2016 Apr; 57(4):463-7. PubMed ID: 25940064
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Metal-on-metal hip replacement: a new concept for an old problem?
    Segal O; Maoz-Segal R
    Isr Med Assoc J; 2013 Nov; 15(11):722-4. PubMed ID: 24511659
    [No Abstract]   [Full Text] [Related]  

  • 5. The Effectiveness of Blood Metal Ions in Identifying Patients with Unilateral Birmingham Hip Resurfacing and Corail-Pinnacle Metal-on-Metal Hip Implants at Risk of Adverse Reactions to Metal Debris.
    Matharu GS; Berryman F; Brash L; Pynsent PB; Treacy RB; Dunlop DJ
    J Bone Joint Surg Am; 2016 Apr; 98(8):617-26. PubMed ID: 27098320
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Metal-on-metal hip arthroplasty: going, going, gone... - affirms.
    Berend KR; Morris MJ; Adams JB; Lombardi AV
    J Bone Joint Surg Br; 2012 Nov; 94(11 Suppl A):75-7. PubMed ID: 23118387
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Meeting the demands of on-going metal-on-metal hip surveillance through nurse led services.
    Elliott S; Langfield S
    Int J Orthop Trauma Nurs; 2016 Feb; 20():40-4. PubMed ID: 26772766
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Catastrophic failure due to massive osteolysis of both acetabular and femoral components in a metal-on-metal hip arthroplasty: a demonstrative case report.
    Gutman G; Hershkovich O; Amit Y; Israeli A
    Eur J Orthop Surg Traumatol; 2013 Nov; 23 Suppl 2():S225-8. PubMed ID: 23412220
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Faulty implants: the court of appeal has ruled surgeon's responsibility].
    Theissen A; Pujol N; Catineau J; Niccolai P; Carles M
    Ann Chir Plast Esthet; 2013 Aug; 58(4):267-70. PubMed ID: 23453252
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Current concepts in hip arthroplasty imaging: metal-on-metal prostheses, their complications, and imaging strategies.
    Bestic JM; Berquist TH
    Semin Roentgenol; 2013 Apr; 48(2):178-86. PubMed ID: 23452465
    [No Abstract]   [Full Text] [Related]  

  • 11. The pathology of failed McKee-Farrar implants: correlation with modern metal-on-metal-implant failure.
    Munemoto M; Grammatopoulos G; Tanaka Y; Gibbons M; Athanasou NA
    J Mater Sci Mater Med; 2017 May; 28(5):66. PubMed ID: 28332156
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ceramic on ceramic hip prostheses: a review of past and modern materials.
    Macdonald N; Bankes M
    Arch Orthop Trauma Surg; 2014 Sep; 134(9):1325-33. PubMed ID: 25038921
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The correlation of wear with histological features after failed hip resurfacing arthroplasty.
    Grammatopoulos G; Pandit H; Kamali A; Maggiani F; Glyn-Jones S; Gill HS; Murray DW; Athanasou N
    J Bone Joint Surg Am; 2013 Jun; 95(12):e81. PubMed ID: 23783212
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Notching of the femoral stem neck in metal-on-metal total hip replacement: a case report.
    Leung KH; Chiu KY; Ng FY; Yin L
    J Orthop Surg (Hong Kong); 2013 Apr; 21(1):113-6. PubMed ID: 23630003
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Revision of Metal-on-metal Hip Prostheses Results in Marked Reduction of Blood Cobalt and Chromium Ion Concentrations.
    Lainiala O; Reito A; Elo P; Pajamäki J; Puolakka T; Eskelinen A
    Clin Orthop Relat Res; 2015 Jul; 473(7):2305-13. PubMed ID: 25623595
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Metal-on-metal hip implants: recognizing symptoms.
    Mayo Clin Health Lett; 2013 Aug; 31(8):4. PubMed ID: 24712063
    [No Abstract]   [Full Text] [Related]  

  • 17. [Low-Carbon Metal-on-Metal Articulations for Hip Arthroplasties--Evaluation of Wear and Histology after 11 to 17 Years].
    Reinisch G; Huber M; Zweymüller KA
    Z Orthop Unfall; 2015 Aug; 153(4):392-8. PubMed ID: 25993351
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Which factors determine the wear rate of large-diameter metal-on-metal hip replacements? Multivariate analysis of two hundred and seventy-six components.
    Hart AJ; Muirhead-Allwood S; Porter M; Matthies A; Ilo K; Maggiore P; Underwood R; Cann P; Cobb J; Skinner JA
    J Bone Joint Surg Am; 2013 Apr; 95(8):678-85. PubMed ID: 23595065
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Three metal-on-metal hip replacement devices from the same manufacturer--a short- to mid-term survival.
    Kostensalo I; Junnila M; Mokka J; Virolainen P; Vahlberg T; Mäkelä KT
    Acta Orthop Belg; 2014 Jun; 80(2):222-7. PubMed ID: 25090796
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Metal-on-metal hip arthroplasty: going, going, gone... - opposes.
    Benjamin-Laing H; Haddad FS
    J Bone Joint Surg Br; 2012 Nov; 94(11 Suppl A):78-81. PubMed ID: 23118388
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.