These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

237 related articles for article (PubMed ID: 2793200)

  • 1. A quasi-static model for the ring capacitor applicator.
    Sowiński MJ; van Putten MH; van den Berg PM; van Rhoon GC
    IEEE Trans Biomed Eng; 1989 Oct; 36(10):995-1003. PubMed ID: 2793200
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A computational model for heat generation in a radially layered tissue inside a 'coaxial TEM' applicator.
    Zwamborn AP; Van den Berg PM
    Int J Hyperthermia; 1989; 5(2):211-23. PubMed ID: 2926186
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A three-dimensional iterative scheme for an electromagnetic inductive applicator.
    Sowiński MJ; van den Berg PM
    IEEE Trans Biomed Eng; 1992 Dec; 39(12):1255-64. PubMed ID: 1487288
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A three-dimensional model for the 'coaxial TEM' deep-body hyperthermia applicator.
    van Putten MH; van den Berg PM
    Int J Hyperthermia; 1986; 2(3):243-52. PubMed ID: 3794420
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A numerical method for the computation of induced currents inside 3-D heterogeneous biological bodies by ELF--LF electric fields.
    Chuang HR; Chen KM
    IEEE Trans Biomed Eng; 1989 Jun; 36(6):628-34. PubMed ID: 2731949
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Localized heating characteristics of hyperthermia using a reentrant cavity.
    Ishihara Y; Wadamori N
    J Med Eng Technol; 2008; 32(5):348-57. PubMed ID: 18821413
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Numerical dosimetry ELF: accuracy of the method, variability of models and parameters, and the implication for quantifying guidelines.
    Bahr A; Bolz T; Hennes C
    Health Phys; 2007 Jun; 92(6):521-30. PubMed ID: 17495652
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A water-cooled EM applicator radiating in a phantom equivalent tissue--experiments and numerical analysis.
    Gentili GB; Gori F; Lachi L; Leoncini M
    IEEE Trans Biomed Eng; 1991 Sep; 38(9):924-8. PubMed ID: 1743741
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An inverse method to optimize heating conditions in RF-capacitive hyperthermia.
    Tsuda N; Kuroda K; Suzuki Y
    IEEE Trans Biomed Eng; 1996 Oct; 43(10):1029-37. PubMed ID: 9214820
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A ring capacitor applicator in hyperthermia: energy distributions in a fat-muscle layered model for different ring electrode configurations.
    van Rhoon GC; Sowinski MJ; van den Berg PM; Visser AG; Reinhold HS
    Int J Radiat Oncol Biol Phys; 1990 Jan; 18(1):77-85. PubMed ID: 2298638
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Applicator modeling for electromagnetic thermotherapy of cervix cancer.
    Rezaeealam B
    Electromagn Biol Med; 2015 Mar; 34(1):43-7. PubMed ID: 24460419
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A three-dimensional iterative scheme for an electromagnetic capacitive applicator.
    Sowiński MJ; van den Berg PM
    IEEE Trans Biomed Eng; 1990 Oct; 37(10):975-86. PubMed ID: 2249870
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optimal steady-state temperature distribution for a phased array hyperthermia system.
    Nikita KS; Maratos NG; Uzunoglu NK
    IEEE Trans Biomed Eng; 1993 Dec; 40(12):1299-306. PubMed ID: 8125505
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cylindrical tissue model for magnetic field stimulation of neurons: effects of coil geometry.
    Esselle KP; Stuchly MA
    IEEE Trans Biomed Eng; 1995 Sep; 42(9):934-41. PubMed ID: 7558068
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Measures of specific absorption rate (SAR) in microwave hyperthermic oncology and the influence of the dynamic bolus on clinical practice].
    Marini P; Guiot C; Baiotto B; Gabriele P
    Radiol Med; 2001 Sep; 102(3):159-67. PubMed ID: 11677459
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Optimization of the deposited power distribution inside a layered lossy medium irradiated by a coupled system of concentrically placed waveguide applicators.
    Nikita KS; Maratos NG; Uzunoglu NK
    IEEE Trans Biomed Eng; 1998 Jul; 45(7):909-20. PubMed ID: 9644900
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An RF concentrating method using inductive aperture-type applicators.
    Fujita Y; Kato H; Ishida T
    IEEE Trans Biomed Eng; 1993 Jan; 40(1):110-3. PubMed ID: 8468071
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of electrical fields inside a biological structure.
    Drago GP; Ridella S
    Br J Cancer Suppl; 1982 Mar; 5():215-9. PubMed ID: 6279135
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Computational feasibility of deformable mirror microwave hyperthermia technique for localized breast tumors.
    Arunachalam K; Udpa SS; Udpa L
    Int J Hyperthermia; 2007 Nov; 23(7):577-89. PubMed ID: 18038288
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Quasi-static electric field in a cylindrical volume conductor induced by external coils.
    Esselle KP; Stuchly MA
    IEEE Trans Biomed Eng; 1994 Feb; 41(2):151-8. PubMed ID: 8026848
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.