These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 2793729)

  • 1. Minimization of lung pressure swings during high-frequency ventilation: a model.
    Khoo MC; Yamashiro SM; Yamashiro P
    J Appl Physiol (1985); 1989 Sep; 67(3):993-1000. PubMed ID: 2793729
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Lung pressures and gas transport during high-frequency airway and chest wall oscillation.
    Khoo MC; Ye TH; Tran NH
    J Appl Physiol (1985); 1989 Sep; 67(3):985-92. PubMed ID: 2793728
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optimal application of high-frequency ventilation in infants: a theoretical study.
    Ghazanshahi SD; Khoo MC
    IEEE Trans Biomed Eng; 1993 Aug; 40(8):788-96. PubMed ID: 8258445
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An in vitro assessment of gas trapping during high frequency oscillation.
    Leipälä JA; Sharma A; Lee S; Milner AD; Greenough A
    Physiol Meas; 2005 Jun; 26(3):329-36. PubMed ID: 15798306
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Deviation of tracheal pressure from airway opening pressure during high-frequency oscillatory ventilation in a porcine lung model.
    Johannes A; Zollhoefer B; Eujen U; Kredel M; Rauch S; Roewer N; Muellenbach RM
    Exp Lung Res; 2013 Apr; 39(3):130-5. PubMed ID: 23458472
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High-frequency ventilation: a review.
    Chang HK; Harf A
    Respir Physiol; 1984 Aug; 57(2):135-52. PubMed ID: 6387837
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Alveolar pressure magnitude and asynchrony during high-frequency oscillations of excised rabbit lungs.
    Allen JL; Fredberg JJ; Keefe DH; Frantz ID
    Am Rev Respir Dis; 1985 Aug; 132(2):343-9. PubMed ID: 4026057
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Regional gas transport in the heterogeneous lung during oscillatory ventilation.
    Herrmann J; Tawhai MH; Kaczka DW
    J Appl Physiol (1985); 2016 Dec; 121(6):1306-1318. PubMed ID: 27763872
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Higher frequency ventilation attenuates lung injury during high-frequency oscillatory ventilation in sheep models of acute respiratory distress syndrome.
    Liu S; Yi Y; Wang M; Chen Q; Huang Y; Liu L; Xie J; Zhou D; Qiu H
    Anesthesiology; 2013 Aug; 119(2):398-411. PubMed ID: 23598290
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of frequency on pressure cost of ventilation and gas exchange in newborns receiving high-frequency oscillatory ventilation.
    Zannin E; Dellaca' RL; Dognini G; Marconi L; Perego M; Pillow JJ; Tagliabue PE; Ventura ML
    Pediatr Res; 2017 Dec; 82(6):994-999. PubMed ID: 28665929
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Tracheal gas insufflation as a lung-protective strategy: physiologic, histologic, and biochemical markers.
    Oliver RE; Rozycki HJ; Greenspan JS; Wolfson MR; Shaffer TH
    Pediatr Crit Care Med; 2005 Jan; 6(1):64-9. PubMed ID: 15636662
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Positive pressure ventilation with the open lung concept optimizes gas exchange and reduces ventilator-induced lung injury in newborn piglets.
    van Kaam AH; de Jaegere A; Haitsma JJ; Van Aalderen WM; Kok JH; Lachmann B
    Pediatr Res; 2003 Feb; 53(2):245-53. PubMed ID: 12538782
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Tracheal gas insufflation-pressure control versus volume control ventilation. A lung model study.
    Imanaka H; Kacmarek RM; Ritz R; Hess D
    Am J Respir Crit Care Med; 1996 Mar; 153(3):1019-24. PubMed ID: 8630540
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Regional lung mechanics and gas transport in lungs with inhomogeneous compliance.
    Tsuzaki K; Hales CA; Strieder DJ; Venegas JG
    J Appl Physiol (1985); 1993 Jul; 75(1):206-16. PubMed ID: 8376266
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Influence of inertance on respiratory mechanics measurements in mechanically ventilated puppies.
    Lanteri CJ; Petak F; Gurrin L; Sly PD
    Pediatr Pulmonol; 1999 Aug; 28(2):130-8. PubMed ID: 10423313
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biologic variability in mechanical ventilation rate and tidal volume does not improve oxygenation or lung mechanics in canine oleic acid lung injury.
    Nam AJ; Brower RG; Fessler HE; Simon BA
    Am J Respir Crit Care Med; 2000 Jun; 161(6):1797-804. PubMed ID: 10852747
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Assessment of dynamic mechanical properties of the respiratory system during high-frequency oscillatory ventilation*.
    Dellacà RL; Zannin E; Ventura ML; Sancini G; Pedotti A; Tagliabue P; Miserocchi G
    Crit Care Med; 2013 Nov; 41(11):2502-11. PubMed ID: 23760105
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Intra-airway gas transport during high-frequency chest vibration with tracheal insufflation in dogs.
    Gavriely N; Eckmann DM; Grotberg JB
    J Appl Physiol (1985); 1995 Jul; 79(1):243-50. PubMed ID: 7559227
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Airway pressures in an asymmetrically branched airway model of the dog respiratory system.
    Jackson AC; Tabrizi M; Kotlikoff MI; Voss JR
    J Appl Physiol Respir Environ Exerc Physiol; 1984 Oct; 57(4):1223-30. PubMed ID: 6438032
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Lung and chest wall mechanics in rabbits during high-frequency body-surface oscillation.
    Chartrand DA; Maarek JM; Ye TH; Chang HK
    J Appl Physiol (1985); 1990 Apr; 68(4):1722-6. PubMed ID: 2347810
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.