178 related articles for article (PubMed ID: 27940168)
1. Developing a non-fouling hybrid microfluidic device for applications in circulating tumour cell detections.
Qin Y; Yang X; Zhang J; Cao X
Colloids Surf B Biointerfaces; 2017 Mar; 151():39-46. PubMed ID: 27940168
[TBL] [Abstract][Full Text] [Related]
2. Developing an ultra non-fouling SU-8 and PDMS hybrid microfluidic device by poly(amidoamine) engraftment.
Qin Y; Yeh P; Hao X; Cao X
Colloids Surf B Biointerfaces; 2015 Mar; 127():247-55. PubMed ID: 25687095
[TBL] [Abstract][Full Text] [Related]
3. Nonfouling hydrophilic poly(ethylene glycol) engraftment strategy for PDMS/SU-8 heterogeneous microfluidic devices.
Yeh PY; Zhang Z; Lin M; Cao X
Langmuir; 2012 Nov; 28(46):16227-36. PubMed ID: 23110374
[TBL] [Abstract][Full Text] [Related]
4. One-step in-mould modification of PDMS surfaces and its application in the fabrication of self-driven microfluidic channels.
Fatona A; Chen Y; Reid M; Brook MA; Moran-Mirabal JM
Lab Chip; 2015 Nov; 15(22):4322-30. PubMed ID: 26400365
[TBL] [Abstract][Full Text] [Related]
5. Aptamer surface functionalization of microfluidic devices using dendrimers as multi-handled templates and its application in sensitive detections of foodborne pathogenic bacteria.
Hao X; Yeh P; Qin Y; Jiang Y; Qiu Z; Li S; Le T; Cao X
Anal Chim Acta; 2019 May; 1056():96-107. PubMed ID: 30797466
[TBL] [Abstract][Full Text] [Related]
6. Recent developments in PDMS surface modification for microfluidic devices.
Zhou J; Ellis AV; Voelcker NH
Electrophoresis; 2010 Jan; 31(1):2-16. PubMed ID: 20039289
[TBL] [Abstract][Full Text] [Related]
7. Target capturing performance of microfluidic channel surface immobilized aptamers: the effects of spacer lengths.
Qin Y; Yang X; Zhang J; Cao X
Biomed Microdevices; 2019 Jun; 21(3):54. PubMed ID: 31203429
[TBL] [Abstract][Full Text] [Related]
8. Simple Surface Modification of Poly(dimethylsiloxane) via Surface Segregating Smart Polymers for Biomicrofluidics.
Gökaltun A; Kang YBA; Yarmush ML; Usta OB; Asatekin A
Sci Rep; 2019 May; 9(1):7377. PubMed ID: 31089162
[TBL] [Abstract][Full Text] [Related]
9. Surface Modification Techniques for Endothelial Cell Seeding in PDMS Microfluidic Devices.
Akther F; Yakob SB; Nguyen NT; Ta HT
Biosensors (Basel); 2020 Nov; 10(11):. PubMed ID: 33228050
[TBL] [Abstract][Full Text] [Related]
10. Poly(oxyethylene) based surface coatings for poly(dimethylsiloxane) microchannels.
Hellmich W; Regtmeier J; Duong TT; Ros R; Anselmetti D; Ros A
Langmuir; 2005 Aug; 21(16):7551-7. PubMed ID: 16042494
[TBL] [Abstract][Full Text] [Related]
11. Deoxyribonucleic acid modified poly(dimethylsiloxane) microfluidic channels for the enhancement of microchip electrophoresis.
Liang R; Hu P; Gan G; Qiu J
Talanta; 2009 Mar; 77(5):1647-53. PubMed ID: 19159778
[TBL] [Abstract][Full Text] [Related]
12. Modification of the glass surface property in PDMS-glass hybrid microfluidic devices.
Kaneda S; Ono K; Fukuba T; Nojima T; Yamamoto T; Fujii T
Anal Sci; 2012; 28(1):39-44. PubMed ID: 22232222
[TBL] [Abstract][Full Text] [Related]
13. Improved cell adhesion under shear stress in PDMS microfluidic devices.
Siddique A; Meckel T; Stark RW; Narayan S
Colloids Surf B Biointerfaces; 2017 Feb; 150():456-464. PubMed ID: 27847226
[TBL] [Abstract][Full Text] [Related]
14. Easy-to-fabricate thin-film coating on PDMS substrate with super hydrophilicity and stability.
Sun L; Luo Y; Gao Z; Zhao W; Lin B
Electrophoresis; 2015 Mar; 36(6):889-92. PubMed ID: 25521081
[TBL] [Abstract][Full Text] [Related]
15. Selective functionalisation of PDMS-based photonic lab on a chip for biosensing.
Ibarlucea B; Fernández-Sánchez C; Demming S; Büttgenbach S; Llobera A
Analyst; 2011 Sep; 136(17):3496-502. PubMed ID: 21336349
[TBL] [Abstract][Full Text] [Related]
16. Flow-through functionalized PDMS microfluidic channels with dextran derivative for ELISAs.
Yu L; Li CM; Liu Y; Gao J; Wang W; Gan Y
Lab Chip; 2009 May; 9(9):1243-7. PubMed ID: 19370243
[TBL] [Abstract][Full Text] [Related]
17. Stability of Polyethylene Glycol and Zwitterionic Surface Modifications in PDMS Microfluidic Flow Chambers.
Plegue TJ; Kovach KM; Thompson AJ; Potkay JA
Langmuir; 2018 Jan; 34(1):492-502. PubMed ID: 29231737
[TBL] [Abstract][Full Text] [Related]
18. Microfluidic enzymatic-reactors for peptide mapping: strategy, characterization, and performance.
Wu H; Zhai J; Tian Y; Lu H; Wang X; Jia W; Liu B; Yang P; Xu Y; Wang H
Lab Chip; 2004 Dec; 4(6):588-97. PubMed ID: 15570370
[TBL] [Abstract][Full Text] [Related]
19. Protein immobilization on the surface of polydimethylsiloxane and polymethyl methacrylate microfluidic devices.
Khnouf R; Karasneh D; Albiss BA
Electrophoresis; 2016 Feb; 37(3):529-35. PubMed ID: 26534833
[TBL] [Abstract][Full Text] [Related]
20. Polyurethane-based microfluidic devices for blood contacting applications.
Wu WI; Sask KN; Brash JL; Selvaganapathy PR
Lab Chip; 2012 Mar; 12(5):960-70. PubMed ID: 22273592
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]