BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

595 related articles for article (PubMed ID: 27941226)

  • 1. Estimating head and neck tissue dose from x-ray scatter to physicians performing x-ray guided cardiovascular procedures: a phantom study.
    Fetterly KA; Schueler BA; Grams MP; Sturchio GM
    J Radiol Prot; 2017 Mar; 37(1):43-58. PubMed ID: 27941226
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Head and Neck Radiation Dose and Radiation Safety for Interventional Physicians.
    Fetterly K; Schueler B; Grams M; Sturchio G; Bell M; Gulati R
    JACC Cardiovasc Interv; 2017 Mar; 10(5):520-528. PubMed ID: 28279321
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Radiation brain dose to vascular surgeons during fluoroscopically guided interventions is not effectively reduced by wearing lead equivalent surgical caps.
    Kirkwood ML; Arbique GM; Guild JB; Zeng K; Xi Y; Rectenwald J; Anderson JA; Timaran C
    J Vasc Surg; 2018 Aug; 68(2):567-571. PubMed ID: 29544995
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Real-time, ray casting-based scatter dose estimation for c-arm x-ray system.
    Alnewaini Z; Langer E; Schaber P; David M; Kretz D; Steil V; Hesser J
    J Appl Clin Med Phys; 2017 Mar; 18(2):144-153. PubMed ID: 28300387
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Application of the diagnostic radiological index of protection to protective garments.
    Pasciak AS; Jones AK; Wagner LK
    Med Phys; 2015 Feb; 42(2):653-662. PubMed ID: 28102605
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A measurement-based X-ray source model characterization for CT dosimetry computations.
    Sommerville M; Poirier Y; Tambasco M
    J Appl Clin Med Phys; 2015 Nov; 16(6):386-400. PubMed ID: 26699546
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Intraoperative cone-beam CT for guidance of head and neck surgery: Assessment of dose and image quality using a C-arm prototype.
    Daly MJ; Siewerdsen JH; Moseley DJ; Jaffray DA; Irish JC
    Med Phys; 2006 Oct; 33(10):3767-80. PubMed ID: 17089842
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Implementation of radiochromic film dosimetry protocol for volumetric dose assessments to various organs during diagnostic CT procedures.
    Brady S; Yoshizumi T; Toncheva G; Frus D
    Med Phys; 2010 Sep; 37(9):4782-92. PubMed ID: 20964198
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Wedge factor constituents of high-energy photon beams: head and phantom scatter dose components.
    Heukelom S; Lanson JH; Mijnheer BJ
    Radiother Oncol; 1994 Jul; 32(1):73-83. PubMed ID: 7938681
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fluoroscopically guided percutaneous vertebroplasty: assessment of radiation doses and implementation of procedural routines to reduce operator exposure.
    von Wrangel A; Cederblad A; Rodriguez-Catarino M
    Acta Radiol; 2009 Jun; 50(5):490-6. PubMed ID: 19363715
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Novel lead-free drape applied to the X-ray detector protects against scatter radiation in the angiography suite.
    Irani Z; Alexander B; Zhang D; Liu B; Ghoshhajra B; Oklu R
    J Vasc Interv Radiol; 2014 Aug; 25(8):1200-8. PubMed ID: 24985717
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Assessing doses to interventional radiologists using a personal dosimeter worn over a protective apron.
    Stranden E; Widmark A; Sekse T
    Acta Radiol; 2008 May; 49(4):415-8. PubMed ID: 18415785
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Modified design of x-ray protective clothing to enhance radiation protection for interventional radiologists.
    Choi TW; Chung JW; Kwon Y
    Med Phys; 2023 Jun; 50(6):3825-3832. PubMed ID: 36794321
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Radiation exposure benefit of a lead cap in invasive cardiology.
    Kuon E; Birkel J; Schmitt M; Dahm JB
    Heart; 2003 Oct; 89(10):1205-10. PubMed ID: 12975420
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Radiation Exposure of Interventional Radiologists During Computed Tomography Fluoroscopy-Guided Renal Cryoablation and Lung Radiofrequency Ablation: Direct Measurement in a Clinical Setting.
    Matsui Y; Hiraki T; Gobara H; Iguchi T; Fujiwara H; Kawabata T; Yamauchi T; Yamaguchi T; Kanazawa S
    Cardiovasc Intervent Radiol; 2016 Jun; 39(6):894-901. PubMed ID: 26911733
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of an X-Ray Dose Profile Derived from an Optically Stimulated Luminescent Dosimeter during Computed Tomographic Fluoroscopy.
    Hasegawa H; Sato M; Tanaka H
    PLoS One; 2015; 10(7):e0132154. PubMed ID: 26151914
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optimizing Staff Dose in Fluoroscopy-Guided Interventions by Comparing Clinical Data with Phantom Experiments.
    Sailer AM; Paulis L; Vergoossen L; Wildberger JE; Jeukens CRLPN
    J Vasc Interv Radiol; 2019 May; 30(5):701-708.e1. PubMed ID: 30952523
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A model-based approach of scatter dose contributions and efficiency of apron shielding for radiation protection in CT.
    Weber N; Monnin P; Elandoy C; Ding S
    Phys Med; 2015 Dec; 31(8):889-896. PubMed ID: 26112350
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Evolution of radiation exposure to operator in diagnostic and interventional radiology procedures and reduction of radiation exposure to operator with protective device].
    Iida H; Horii J; Chabatake M; Mizushima T
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2004 Dec; 60(12):1713-22. PubMed ID: 15614223
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Flattening filter free beams in SBRT and IMRT: dosimetric assessment of peripheral doses.
    Kragl G; Baier F; Lutz S; Albrich D; Dalaryd M; Kroupa B; Wiezorek T; Knöös T; Georg D
    Z Med Phys; 2011 May; 21(2):91-101. PubMed ID: 20888199
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 30.