These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

371 related articles for article (PubMed ID: 27956677)

  • 1. Effects of pneumoperitoneum and Trendelenburg position on intracranial pressure assessed using different non-invasive methods.
    Robba C; Cardim D; Donnelly J; Bertuccio A; Bacigaluppi S; Bragazzi N; Cabella B; Liu X; Matta B; Lattuada M; Czosnyka M
    Br J Anaesth; 2016 Dec; 117(6):783-791. PubMed ID: 27956677
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Increase in intracranial pressure during carbon dioxide pneumoperitoneum with steep trendelenburg positioning proven by ultrasonographic measurement of optic nerve sheath diameter.
    Kim MS; Bai SJ; Lee JR; Choi YD; Kim YJ; Choi SH
    J Endourol; 2014 Jul; 28(7):801-6. PubMed ID: 24517270
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Sonographic optic nerve sheath diameter as a surrogate measure for intracranial pressure in anesthetized patients in the Trendelenburg position.
    Chin JH; Seo H; Lee EH; Lee J; Hong JH; Hwang JH; Kim YK
    BMC Anesthesiol; 2015; 15():43. PubMed ID: 25861241
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of optic nerve sheath diameter in patients undergoing laparoscopic surgery in the Trendelenburg position: a prospective observational study.
    Ömür B; Çiftçi B; Karaaslan P
    Ann Saudi Med; 2024; 44(5):319-328. PubMed ID: 39368121
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Noninvasive Intracranial Pressure Assessment in Acute Liver Failure.
    Rajajee V; Williamson CA; Fontana RJ; Courey AJ; Patil PG
    Neurocrit Care; 2018 Oct; 29(2):280-290. PubMed ID: 29948998
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Improved diagnostic value of a TCD-based non-invasive ICP measurement method compared with the sonographic ONSD method for detecting elevated intracranial pressure.
    Ragauskas A; Bartusis L; Piper I; Zakelis R; Matijosaitis V; Petrikonis K; Rastenyte D
    Neurol Res; 2014 Jul; 36(7):607-14. PubMed ID: 24620972
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Intraoperative non invasive intracranial pressure monitoring during pneumoperitoneum: a case report and a review of the published cases and case report series.
    Robba C; Bacigaluppi S; Cardim D; Donnelly J; Sekhon MS; Aries MJ; Mancardi G; Booth A; Bragazzi NL; Czosnyka M; Matta B
    J Clin Monit Comput; 2016 Oct; 30(5):527-38. PubMed ID: 26342642
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of Pneumoperitoneum and Patient Positioning on Intracranial Pressures during Laparoscopy: A Prospective Comparative Study.
    Sahay N; Sharma S; Bhadani UK; Singh A; Sinha C; Sahay A; Ranjan A; Agarwal M
    J Minim Invasive Gynecol; 2018 Jan; 25(1):147-152. PubMed ID: 28918894
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of Mannitol on Ultrasonographically Measured Optic Nerve Sheath Diameter as a Surrogate for Intracranial Pressure During Robot-Assisted Laparoscopic Prostatectomy with Pneumoperitoneum and the Trendelenburg Position.
    Jun IJ; Kim M; Lee J; Park SU; Hwang JH; Hong JH; Kim YK
    J Endourol; 2018 Jul; 32(7):608-613. PubMed ID: 29415565
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of pneumoperitoneum and Trendelenburg position on intracranial pressure and cerebral blood flow assessed using transcranial doppler: A prospective observational study.
    Joseph A; Theerth KA; Karipparambath V; Palliyil A
    J Anaesthesiol Clin Pharmacol; 2023; 39(3):429-434. PubMed ID: 38025577
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Detection of elevated intracranial pressure in robot-assisted laparoscopic radical prostatectomy using ultrasonography of optic nerve sheath diameter.
    Whiteley JR; Taylor J; Henry M; Epperson TI; Hand WR
    J Neurosurg Anesthesiol; 2015 Apr; 27(2):155-9. PubMed ID: 25105824
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ultrasonographic optic nerve sheath diameter for predicting elevated intracranial pressure during laparoscopic surgery: a systematic review and meta-analysis.
    Kim EJ; Koo BN; Choi SH; Park K; Kim MS
    Surg Endosc; 2018 Jan; 32(1):175-182. PubMed ID: 28639043
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of Prone Position and Positive End-Expiratory Pressure on Noninvasive Estimators of ICP: A Pilot Study.
    Robba C; Bragazzi NL; Bertuccio A; Cardim D; Donnelly J; Sekhon M; Lavinio A; Duane D; Burnstein R; Matta B; Bacigaluppi S; Lattuada M; Czosnyka M
    J Neurosurg Anesthesiol; 2017 Jul; 29(3):243-250. PubMed ID: 26998650
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of the effect of trendelenburg position duration on intracranial pressure in laparoscopic hysterectomies using ultrasonographic optic nerve sheath diameter measurements.
    Guloglu H; Cetinkaya D; Oge T; Bilir A
    BMC Anesthesiol; 2024 Jul; 24(1):238. PubMed ID: 39010013
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ultrasonographic measured optic nerve sheath diameter as an accurate and quick monitor for changes in intracranial pressure.
    Maissan IM; Dirven PJ; Haitsma IK; Hoeks SE; Gommers D; Stolker RJ
    J Neurosurg; 2015 Sep; 123(3):743-7. PubMed ID: 25955869
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Non-invasive Intracranial Pressure Assessment in Brain Injured Patients Using Ultrasound-Based Methods.
    Robba C; Cardim D; Tajsic T; Pietersen J; Bulman M; Rasulo F; Bertuetti R; Donnelly J; Xiuyun L; Czosnyka Z; Cabeleira M; Smielewski P; Matta B; Bertuccio A; Czosnyka M
    Acta Neurochir Suppl; 2018; 126():69-73. PubMed ID: 29492535
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Changes in intraocular pressure and optic nerve sheath diameter in patients undergoing robotic-assisted laparoscopic prostatectomy in steep 45° Trendelenburg position.
    Blecha S; Harth M; Schlachetzki F; Zeman F; Blecha C; Flora P; Burger M; Denzinger S; Graf BM; Helbig H; Pawlik MT
    BMC Anesthesiol; 2017 Mar; 17(1):40. PubMed ID: 28284189
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The effect of pneumoperitoneum and Trendelenburg position on optic nerve sheath diameter in patients undergoing laparoscopic hysterectomy.
    Bayramov T; Kilicaslan B; Akinci SB; Boyraz G
    J Obstet Gynaecol Res; 2022 Mar; 48(3):830-837. PubMed ID: 35048472
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of the effect of fluid management on intracranial pressure in patients undergoing laparoscopic gynaecological surgery based on the ratio of the optic nerve sheath diameter to the eyeball transverse diameter as measured by ultrasound: a randomised controlled trial.
    Huang Y; Cai Y; Peng MQ; Yi TT
    BMC Anesthesiol; 2024 Sep; 24(1):319. PubMed ID: 39244545
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The effect of prolonged steep head-down laparoscopy on the optical nerve sheath diameter.
    Colombo R; Agarossi A; Borghi B; Ottolina D; Bergomi P; Ballone E; Minari C; Della Porta V; Menozzi E; Figini S; Fossali T; Catena E
    J Clin Monit Comput; 2020 Dec; 34(6):1295-1302. PubMed ID: 31691148
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 19.