These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 2795723)

  • 21. Diagnosis of penile hemangioma by use of biopty gun for corpus cavernosum biopsy.
    Heidenreich A; Zumbé J; Engelmann UH; Schäfer R; von Vietsch H
    Eur Urol; 1995; 27(3):257-60. PubMed ID: 7601194
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Testicular needle biopsy: is it a safe and adequate method?
    Odabaş O; Uğraş S; Yilmaz Y; Aydin S; Atilla MK
    Int Urol Nephrol; 1997; 29(5):591-5. PubMed ID: 9413768
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Testicular needle biopsy in diagnosis of infertility.
    Cohen MS; Frye S; Warner RS; Leiter E
    Urology; 1984 Nov; 24(5):439-42. PubMed ID: 6495452
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Percutaneous renal biopsy using Biopty biopsy instrument and Biopty biopsy needle].
    Hayashi Y; Makino H; Koumoto J; Nagakane T; Haramoto T; Yamasaki Y; Sasaki T; Yoshida S; Kumagai I; Ota Z
    Nihon Jinzo Gakkai Shi; 1990 Apr; 32(4):415-8. PubMed ID: 2376912
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Ultrasound-guided fine-needle biopsy with an automatic full-incision system: the initial experiences and comparison with a conventional biopsy gun].
    Pokieser P; Kain R; Helbich T; Gebauer A; Neuhold N; Walter R; Tscholakoff D; Mostbeck GH
    Rofo; 1994 Jan; 160(1):70-4. PubMed ID: 8305696
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Study on usefulness of an aspirating biopsy needle (Vacu-Cut) and an automatic biopsy needle (Biopty-Cut) for renal biopsy--comparison with a Tru-Cut biopsy needle].
    Yamamoto S; Iesato K; Ohta Y; Yoshida H
    Nihon Jinzo Gakkai Shi; 1991 Nov; 33(11):1111-7. PubMed ID: 1808362
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Digitally-directed transrectal biopsy using Biopty gun versus transrectal needle aspiration: comparison of diagnostic yield and comfort.
    Renfer LG; Kiesling VJ; Kelley J; Vaccaro JA; Belville WD
    Urology; 1991 Aug; 38(2):108-12. PubMed ID: 1877124
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Controlled comparison of percutaneous and microsurgical sperm retrieval in men with obstructive azoospermia.
    Sheynkin YR; Ye Z; Menendez S; Liotta D; Veeck LL; Schlegel P
    Hum Reprod; 1998 Nov; 13(11):3086-9. PubMed ID: 9853861
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Image-directed percutaneous biopsies with a biopsy gun.
    Parker SH; Hopper KD; Yakes WF; Gibson MD; Ownbey JL; Carter TE
    Radiology; 1989 Jun; 171(3):663-9. PubMed ID: 2655001
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A percutaneous large-needle aspiration biopsy technique for histologic examination of the testis in infertile patients.
    Carpi A; Menchini Fabris F; Gorini I; Gaeta P; Romani R; Marchetti A
    Fertil Steril; 1999 Apr; 71(4):756-60. PubMed ID: 10202893
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Ultrasonography-directed native renal biopsy: comparison of an automated biopsy device with a needle system.
    Kumar A; Mitchell MJ; Aggarwal S; Fraser DB; Trillo AA
    Can Assoc Radiol J; 1992 Oct; 43(5):359-63. PubMed ID: 1393701
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Fine needle tissue aspiration biopsy of the testis.
    Mallidis C; Baker HW
    Fertil Steril; 1994 Feb; 61(2):367-75. PubMed ID: 8299798
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Diagnosis of contralateral testicular intraepithelial neoplasia (TIN) in patients with testicular germ cell cancer: systematic two-site biopsies are more sensitive than a single random biopsy.
    Dieckmann KP; Kulejewski M; Pichlmeier U; Loy V
    Eur Urol; 2007 Jan; 51(1):175-83; discussion 183-5. PubMed ID: 16814456
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Testicular needle aspiration as an alternative to biopsy for the assessment of spermatogenesis.
    Craft I; Tsirigotis M; Courtauld E; Farrer-Brown G
    Hum Reprod; 1997 Jul; 12(7):1483-7. PubMed ID: 9262282
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Efficacy of automated biopsy guns versus conventional biopsy needles in the pygmy pig.
    Hopper KD; Baird DE; Reddy VV; Landis JR; Parker SH; Tyler HN; Ownbey JL; McCauslin MA; Yakes WF; Sabatelli FW
    Radiology; 1990 Sep; 176(3):671-6. PubMed ID: 2389024
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Biopsy of head and neck lesions with a Biopty biopsy instrument].
    Ochi K; Ohashi T; Ogino S; Yazaki H; Kihara N; Mitsui M; Takeyama I
    Nihon Jibiinkoka Gakkai Kaiho; 1992 Apr; 95(4):551-5. PubMed ID: 1602356
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The use of the automatic core biopsy system in percutaneous renal biopsies: a comparative study.
    Burstein DM; Korbet SM; Schwartz MM
    Am J Kidney Dis; 1993 Oct; 22(4):545-52. PubMed ID: 8213794
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Conventional 15 G needle technique for renal biopsy compared with ultrasound-guided spring-loaded 18 G needle biopsy.
    Cozens NJ; Murchison JT; Allan PL; Winney RJ
    Br J Radiol; 1992 Jul; 65(775):594-7. PubMed ID: 1515897
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Percutaneous cutting needle biopsies for histopathological assessment and sperm retrieval in men with azoospermia.
    Rosenlund B; Kvist U; Plöen L; Ekström U; Hovatta O
    Hum Reprod; 2001 Oct; 16(10):2154-9. PubMed ID: 11574508
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Fine needle aspiration cytology compared with open biopsy histology for the diagnosis of azoospermia.
    Qublan HS; Al-Jader KM; Al-Kaisi NS; Alghoweri AS; Abu-Khait SA; Abu-Qamar AA; Haddadin E
    J Obstet Gynaecol; 2002 Sep; 22(5):527-31. PubMed ID: 12521423
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.