These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 27964873)

  • 1. CT image quality assessment by a Channelized Hotelling Observer (CHO): Application to protocol optimization.
    Noferini L; Taddeucci A; Bartolini M; Bruschi A; Menchi I
    Phys Med; 2016 Dec; 32(12):1717-1723. PubMed ID: 27964873
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Computational and human observer image quality evaluation of low dose, knowledge-based CT iterative reconstruction.
    Eck BL; Fahmi R; Brown KM; Zabic S; Raihani N; Miao J; Wilson DL
    Med Phys; 2015 Oct; 42(10):6098-111. PubMed ID: 26429285
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Correlation between a 2D channelized Hotelling observer and human observers in a low-contrast detection task with multislice reading in CT.
    Yu L; Chen B; Kofler JM; Favazza CP; Leng S; Kupinski MA; McCollough CH
    Med Phys; 2017 Aug; 44(8):3990-3999. PubMed ID: 28555878
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Objective assessment of low contrast detectability in computed tomography with Channelized Hotelling Observer.
    Racine D; Ba AH; Ott JG; Bochud FO; Verdun FR
    Phys Med; 2016 Jan; 32(1):76-83. PubMed ID: 26515665
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of supervised-learning approaches for designing a channelized observer for image quality assessment in CT.
    Pouget E; Dedieu V
    Med Phys; 2023 Jul; 50(7):4282-4295. PubMed ID: 36647620
    [TBL] [Abstract][Full Text] [Related]  

  • 6. CHARACTERIZATION OF TWO CT SYSTEMS USING A CHANNELIZED HOTELLING OBSERVER AND NPS METRIC.
    Ortenzia O; D'Alessio A; Noferini L; Ghetti C
    Radiat Prot Dosimetry; 2020 Jul; 189(2):224-233. PubMed ID: 32161966
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Channelized hotelling observer-based low-contrast detectability on the ACR CT accreditation phantom: Part II. Repeatability study.
    Fan M; Zhou Z; McCollough C; Yu L
    Med Phys; 2024 Mar; 51(3):1714-1725. PubMed ID: 38305692
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Prediction of human observer performance in a 2-alternative forced choice low-contrast detection task using channelized Hotelling observer: impact of radiation dose and reconstruction algorithms.
    Yu L; Leng S; Chen L; Kofler JM; Carter RE; McCollough CH
    Med Phys; 2013 Apr; 40(4):041908. PubMed ID: 23556902
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Use of a channelized Hotelling observer to assess CT image quality and optimize dose reduction for iteratively reconstructed images.
    Favazza CP; Ferrero A; Yu L; Leng S; McMillan KL; McCollough CH
    J Med Imaging (Bellingham); 2017 Jul; 4(3):031213. PubMed ID: 28983493
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Quality Assessment of Computed Tomography Images using a Channelized Hoteling Observer: Optimization of Protocols in Clinical Practice.
    Choopani MR; Abedi I; Dalvand F
    Adv Biomed Res; 2023; 12():8. PubMed ID: 36926443
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Assessing image quality and dose reduction of a new x-ray computed tomography iterative reconstruction algorithm using model observers.
    Tseng HW; Fan J; Kupinski MA; Sainath P; Hsieh J
    Med Phys; 2014 Jul; 41(7):071910. PubMed ID: 24989388
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reducing CT radiation dose with iterative reconstruction algorithms: the influence of scan and reconstruction parameters on image quality and CTDIvol.
    Klink T; Obmann V; Heverhagen J; Stork A; Adam G; Begemann P
    Eur J Radiol; 2014 Sep; 83(9):1645-54. PubMed ID: 25037931
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Adaptive nonlocal means filtering based on local noise level for CT denoising.
    Li Z; Yu L; Trzasko JD; Lake DS; Blezek DJ; Fletcher JG; McCollough CH; Manduca A
    Med Phys; 2014 Jan; 41(1):011908. PubMed ID: 24387516
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of the channelized Hotelling observer with an internal-noise model in a train-test paradigm for cardiac SPECT defect detection.
    Brankov JG
    Phys Med Biol; 2013 Oct; 58(20):7159-82. PubMed ID: 24051342
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Correlation between human and model observer performance for discrimination task in CT.
    Zhang Y; Leng S; Yu L; Carter RE; McCollough CH
    Phys Med Biol; 2014 Jul; 59(13):3389-404. PubMed ID: 24875060
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Optimisation of an MDCT abdominal protocol: Image quality assessment of standard vs. iterative reconstructions.
    Berta L; Mascaro L; Feroldi P; Maroldi R
    Phys Med; 2014 May; 30(3):271-9. PubMed ID: 23948366
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Knowledge-based iterative model reconstruction (IMR) algorithm in ultralow-dose CT for evaluation of urolithiasis: evaluation of radiation dose reduction, image quality, and diagnostic performance.
    Park SB; Kim YS; Lee JB; Park HJ
    Abdom Imaging; 2015 Oct; 40(8):3137-46. PubMed ID: 26197735
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of internal noise methods for Hotelling observer models.
    Zhang Y; Pham BT; Eckstein MP
    Med Phys; 2007 Aug; 34(8):3312-22. PubMed ID: 17879795
    [TBL] [Abstract][Full Text] [Related]  

  • 19. CT head-scan dosimetry in an anthropomorphic phantom and associated measurement of ACR accreditation-phantom imaging metrics under clinically representative scan conditions.
    Brunner CC; Stern SH; Minniti R; Parry MI; Skopec M; Chakrabarti K
    Med Phys; 2013 Aug; 40(8):081917. PubMed ID: 23927331
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A performance comparison of anthropomorphic model observers for breast cone beam CT images: A single-slice and multislice study.
    Han M; Baek J
    Med Phys; 2019 Aug; 46(8):3431-3441. PubMed ID: 31106432
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.