These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 27982228)

  • 1. Effect of Glaze Cooling Rate on Mechanical Properties of Conventional and Pressed Porcelain on Zirconia.
    Longhini D; Rocha CO; Medeiros IS; Fonseca RG; Adabo GL
    Braz Dent J; 2016; 27(5):524-531. PubMed ID: 27982228
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pressed ceramics onto zirconia. Part 2: indentation fracture and influence of cooling rate on residual stresses.
    Choi JE; Waddell JN; Swain MV
    Dent Mater; 2011 Nov; 27(11):1111-8. PubMed ID: 21908034
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Thermal-induced residual stresses affect the lifetime of zirconia-veneer crowns.
    Belli R; Frankenberger R; Appelt A; Schmitt J; Baratieri LN; Greil P; Lohbauer U
    Dent Mater; 2013 Feb; 29(2):181-90. PubMed ID: 23261021
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effect of core material, veneering porcelain, and fabrication technique on the biaxial flexural strength and weibull analysis of selected dental ceramics.
    Lin WS; Ercoli C; Feng C; Morton D
    J Prosthodont; 2012 Jul; 21(5):353-62. PubMed ID: 22462639
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pressed ceramics onto zirconia. Part 1: Comparison of crystalline phases present, adhesion to a zirconia system and flexural strength.
    Choi JE; Waddell JN; Torr B; Swain MV
    Dent Mater; 2011 Dec; 27(12):1204-12. PubMed ID: 21958727
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effects of multiple firings on the mechanical properties and microstructure of veneering ceramics for zirconia frameworks.
    Tang X; Nakamura T; Usami H; Wakabayashi K; Yatani H
    J Dent; 2012 May; 40(5):372-80. PubMed ID: 22330322
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Extended glaze firings for porcelain-veneered zirconia: Effects on the mechanical and optical behavior.
    Rodrigues CDS; Aurélio IL; Fraga S; Kaizer MDR; Zhang Y; May LG
    Dent Mater; 2021 Jul; 37(7):1096-1106. PubMed ID: 33865620
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of a novel multiple phase veneering ceramic.
    Sinthuprasirt P; van Noort R; Moorehead R; Pollington S
    Dent Mater; 2015 Apr; 31(4):443-52. PubMed ID: 25682379
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Analysis of subcritical crack growth in dental ceramics using fracture mechanics and fractography.
    Taskonak B; Griggs JA; Mecholsky JJ; Yan JH
    Dent Mater; 2008 May; 24(5):700-7. PubMed ID: 17845817
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of veneering porcelain thickness and cooling rate on residual stresses in zirconia molar crowns.
    Al-Amleh B; Neil Waddell J; Lyons K; Swain MV
    Dent Mater; 2014 Mar; 30(3):271-80. PubMed ID: 24361198
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Load-bearing capacity and failure types of anterior zirconia crowns veneered with overpressing and layering techniques.
    Stawarczyk B; Ozcan M; Roos M; Trottmann A; Sailer I; Hämmerle CH
    Dent Mater; 2011 Oct; 27(10):1045-53. PubMed ID: 21820726
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of porcelain thickness on the flexural strength and crack propagation in a bilayered zirconia system.
    Figueiredo VMG; Pereira SMB; Bressiani E; Valera MC; Bottino MA; Zhang Y; Melo RM
    J Appl Oral Sci; 2017; 25(5):566-574. PubMed ID: 29069155
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The use of slow heating and slow cooling regimens to strengthen porcelain fused to zirconia.
    Tan JP; Sederstrom D; Polansky JR; McLaren EA; White SN
    J Prosthet Dent; 2012 Mar; 107(3):163-9. PubMed ID: 22385692
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Shear bond strengths of pressed and layered veneering ceramics to high-noble alloy and zirconia cores.
    Ishibe M; Raigrodski AJ; Flinn BD; Chung KH; Spiekerman C; Winter RR
    J Prosthet Dent; 2011 Jul; 106(1):29-37. PubMed ID: 21723991
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of slow-cooling protocol on biaxial flexural strengths of bilayered porcelain-ceria-stabilized zirconia/alumina nanocomposite (Ce-TZP/A) disks.
    Sawada T; Wagner V; Schille C; Spintzyk S; Schweizer E; Geis-Gerstorfer J
    Dent Mater; 2019 Feb; 35(2):270-282. PubMed ID: 30522698
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of a conditioning method to improve core-veneer bond strength of zirconia restorations.
    Teng J; Wang H; Liao Y; Liang X
    J Prosthet Dent; 2012 Jun; 107(6):380-7. PubMed ID: 22633594
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of autoclave induced low-temperature degradation on the adhesion energy between yttria-stabilized zirconia veneered with porcelain.
    Li KC; Waddell JN; Prior DJ; Ting S; Girvan L; van Vuuren LJ; Swain MV
    Dent Mater; 2013 Nov; 29(11):e263-70. PubMed ID: 24007922
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The effect of hydrofluoric acid surface treatment and bond strength of a zirconia veneering ceramic.
    Chaiyabutr Y; McGowan S; Phillips KM; Kois JC; Giordano RA
    J Prosthet Dent; 2008 Sep; 100(3):194-202. PubMed ID: 18762031
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Influence of thickness and cooling rate on development of spontaneous cracks in porcelain/zirconia structures.
    Guazzato M; Walton TR; Franklin W; Davis G; Bohl C; Klineberg I
    Aust Dent J; 2010 Sep; 55(3):306-10. PubMed ID: 20887519
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of time period on biaxial strength for different Y-TZP veneering porcelains.
    Fahmi M; Giordano R; Pober R
    J Esthet Restor Dent; 2020 Jul; 32(5):505-511. PubMed ID: 32564471
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.