These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 2798879)

  • 1. New high-flow "cloud" catheter for safer delivery of contrast material.
    Hansen EC; Hawkins MC; Hawkins IF; Akins EW; Miles SG; Collela JP
    Radiology; 1989 Nov; 173(2):461-4. PubMed ID: 2798879
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A solution to the problem of high-flow jets from miniature angiographic catheters.
    Daniel TB; Akins EW; Hawkins IF
    AJR Am J Roentgenol; 1990 May; 154(5):1091-5. PubMed ID: 2108548
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Heating contrast media: role in contemporary angiography.
    Halsell RD
    Radiology; 1987 Jul; 164(1):276-8. PubMed ID: 3588919
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Modifying peripheral IV catheters with side holes and side slits results in favorable changes in fluid dynamic properties during the injection of iodinated contrast material.
    Weber PW; Coursey CA; Howle LE; Nelson RC; Nichols EB; Schindera ST
    AJR Am J Roentgenol; 2009 Oct; 193(4):970-7. PubMed ID: 19770318
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Impact of different vein catheter sizes for mechanical power injection in CT: in vitro evaluation with use of a circulation phantom.
    Behrendt FF; Bruners P; Keil S; Plumhans C; Mahnken AH; Stanzel S; Das M; Günther RW; Mühlenbruch G
    Cardiovasc Intervent Radiol; 2009 Jan; 32(1):25-31. PubMed ID: 18521665
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A proposed mechanism for transient increases in arterial pressure and flow during angiographic injections.
    Wolf GL; Shaw DD; Baltaxe HA; Kilzer K; Kraft L
    Invest Radiol; 1978; 13(3):195-9. PubMed ID: 711394
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Selection of peripheral intravenous catheters with 24-gauge side-holes versus those with 22-gauge end-hole for MDCT: A prospective randomized study.
    Tamura A; Kato K; Kamata M; Suzuki T; Suzuki M; Nakayama M; Tomabechi M; Nakasato T; Ehara S
    Eur J Radiol; 2017 Feb; 87():8-12. PubMed ID: 28065379
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of side hole versus non side hole high flow hemodialysis catheters.
    Tal MG; Peixoto AJ; Crowley ST; Denbow N; Eliseo D; Pollak J
    Hemodial Int; 2006 Jan; 10(1):63-7. PubMed ID: 16441829
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Central venous catheter integrity during mechanical power injection of iodinated contrast medium.
    Macha DB; Nelson RC; Howle LE; Hollingsworth JW; Schindera ST
    Radiology; 2009 Dec; 253(3):870-8. PubMed ID: 19789224
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In vitro study of high-pressure catheters and various contrast agents.
    Rees CR; Merchun G; Becker GJ; Klatte EC; Mail JT; Mulry C
    Radiology; 1988 Jan; 166(1 Pt 1):53-6. PubMed ID: 3336701
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Power injection of microcatheters: an in vitro comparison.
    Brown DB; Papadouris DC; Davis RV; Vedantham S; Pilgram TK
    J Vasc Interv Radiol; 2005 Jan; 16(1):101-6. PubMed ID: 15640416
    [TBL] [Abstract][Full Text] [Related]  

  • 12. High-velocity jets from 5-French catheters.
    Marinelli DL; Kirchhoff R
    AJR Am J Roentgenol; 1991 Apr; 156(4):874-5. PubMed ID: 2003465
    [No Abstract]   [Full Text] [Related]  

  • 13. Injection rate threshold of triple-lumen central venous catheters: an in vitro study.
    Zamos DT; Emch TM; Patton HA; D'Amico FJ; Bansal SK
    Acad Radiol; 2007 May; 14(5):574-8. PubMed ID: 17434071
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Development of multi-purpose catheter for visceral arteriography.
    Yashiro N; Kokubo T; Kawauchi N; Iio M
    Radiat Med; 1989; 7(6):278-81. PubMed ID: 2633215
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The effect of linear contrast flow acceleration on catheter tip recoil in selective arteriography.
    Ringertz HG; Wiley A; Lipton MJ
    Invest Radiol; 1985; 20(2):193-7. PubMed ID: 3988471
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Coeliac angiography with high contrast flow rates (author's transl)].
    Schröder J
    Rofo; 1976 Mar; 124(3):239-41. PubMed ID: 131085
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Contrast media pressure injection using a portal catheter system--results of an in vitro study].
    Gebauer B; Teichgräber UK; Hothan T; Felix R; Wagner HJ
    Rofo; 2005 Oct; 177(10):1417-23. PubMed ID: 16170712
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Haemodynamic effects of intraarterial contrast injections (author's transl)].
    Schröder J; Keller H; Terwey B; Mittmann U
    Rofo; 1981 Aug; 135(2):143-51. PubMed ID: 6212304
    [TBL] [Abstract][Full Text] [Related]  

  • 19. In-line pressures generated in small-bore central venous catheters during power injection of CT contrast media.
    Ruess L; Bulas DI; Rivera O; Markle BM
    Radiology; 1997 Jun; 203(3):625-9. PubMed ID: 9169679
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Prospective study of access site complications of automated contrast injection with peripheral venous access in MDCT.
    Wienbeck S; Fischbach R; Kloska SP; Seidensticker P; Osada N; Heindel W; Juergens KU
    AJR Am J Roentgenol; 2010 Oct; 195(4):825-9. PubMed ID: 20858804
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.