These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

73 related articles for article (PubMed ID: 2799153)

  • 1. [Experiences with the "Balgrist" cement-free, self-anchoring conical acetabular prosthesis--March 1982 to September 1988].
    Hilfiker B; Schreiber A; Jacob HA; Kern S
    Schweiz Rundsch Med Prax; 1989 Aug; 78(31-32):834-9. PubMed ID: 2799153
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [The self-locking Balgrist hip socket for cement-free fixation--history of its development and clinical experience to date].
    Jacob HA; Hilfiker B
    Z Orthop Ihre Grenzgeb; 1990; 128(3):254-61. PubMed ID: 2144072
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [5-t-7-year results of cementless Endler acetabular prosthesis].
    Gut M; Hilfiker B; Schreiber A
    Z Orthop Ihre Grenzgeb; 1990; 128(6):598-605. PubMed ID: 2149239
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Conus hip prosthesis.
    Wagner H; Wagner M
    Acta Chir Orthop Traumatol Cech; 2001; 68(4):213-21. PubMed ID: 11706545
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [The Balgrist hip cup--a 4-to-10-year survival analysis of cement-free hip cups].
    Hauser R; Jacob HA; Kern S; Schreiber A
    Z Orthop Ihre Grenzgeb; 1993; 131(6):585-93. PubMed ID: 8310752
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [5 years' experiences with the Gersthof polyethylene peg-anchored acetabulum].
    Knahr K; Böhler M; Frank P; Plenk H; Salzer M
    Z Orthop Ihre Grenzgeb; 1987; 125(4):375-81. PubMed ID: 3673191
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Good long term results with a cemented straight femoral shaft prosthesis made of titanium].
    Eingartner C; Ihm A; Maurer F; Volkmann R; Weise K; Weller S
    Unfallchirurg; 2002 Sep; 105(9):804-10. PubMed ID: 12232740
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Cementless socket fixation based on the "press-fit" concept in total hip joint arthroplasty].
    Morscher EW; Widmer KH; Bereiter H; Elke R; Schenk R
    Acta Chir Orthop Traumatol Cech; 2002; 69(1):8-15. PubMed ID: 11951572
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Early primary total hip arthroplasty for acetabular fractures in elderly patients].
    Simko P; Braunsteiner T; Vajcziková S
    Acta Chir Orthop Traumatol Cech; 2006 Aug; 73(4):275-82. PubMed ID: 17026887
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Reconstruction of the acetabulum during replacement of the aseptically loosened polyethylene cup].
    Koudela K; Malotín T
    Acta Chir Orthop Traumatol Cech; 2001; 68(3):162-7. PubMed ID: 11706538
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [The Balgrist acetabulum with uncemented endoprosthesis of dysplastic coxarthrosis and other acetabulum defects].
    Hauser R
    Z Orthop Ihre Grenzgeb; 1991; 129(2):183-7. PubMed ID: 1829301
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comparison of the outcome of cemented all-polyethylene and cementless metal-backed acetabular sockets in primary total hip arthroplasty.
    Hartofilakidis G; Georgiades G; Babis GC
    J Arthroplasty; 2009 Feb; 24(2):217-25. PubMed ID: 18534419
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Long-term results of the cementless conical balgrist expansion cup--comparison analysis to the Zweymüller-Alloclassic screw cup].
    Ishaque BA; Basad E; Gils J; Stürz H
    Z Orthop Unfall; 2009; 147(6):707-15. PubMed ID: 20183748
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ceramic endoprosthesis in total hip arthroplasty.
    Riska EB
    Clin Orthop Relat Res; 1993 Dec; (297):87-94. PubMed ID: 8242957
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Revision total hip arthroplasty using a cementless acetabular component: technique and results.
    Silverton CD; Rosenberg AG; Sheinkop MB; Kull LR; Galante JO
    Semin Arthroplasty; 1995 Apr; 6(2):109-17. PubMed ID: 10155687
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Revision of well-fixed cementless acetabular components for polyethylene failure.
    Peters CL; Erickson JA; Dunn HK
    Clin Orthop Relat Res; 2003 Sep; (414):129-35. PubMed ID: 12966286
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A new concept of acetabular fixation.
    Müller ME
    Hip; 1985; ():269-79. PubMed ID: 3830989
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [10-year actuarial analysis of a cohort of 156 total hip prostheses of a cemented polished aluminum/polyethylene alloy].
    Le Mouel S; Allain J; Goutallier D
    Rev Chir Orthop Reparatrice Appar Mot; 1998 Jul; 84(4):338-45. PubMed ID: 9775034
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Uncemented knee prosthesis. Results apropos of 58 cases with a minimum of 5-year follow-up].
    Gacon G; Coillard JY; Barba L; Travers V
    Rev Chir Orthop Reparatrice Appar Mot; 1995; 81(6):505-13. PubMed ID: 8560021
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Cementless acetabular fixation with solid alumina sockets. Apropos of 62 total hybrid prostheses with press-fit alumina sockets at 6-year mean follow-up].
    Hamadouche M; Nizard RS; Meunier A; Sedel L
    Rev Chir Orthop Reparatrice Appar Mot; 2000 Sep; 86(5):474-81. PubMed ID: 10970971
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.