BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 27993219)

  • 21. Evaluation of four mesh fixation methods in an experimental model of ventral hernia repair.
    Chatzimavroudis G; Kalaitzis S; Voloudakis N; Atmatzidis S; Kapoulas S; Koutelidakis I; Papaziogas B; Christoforidis EC
    J Surg Res; 2017 May; 212():253-259. PubMed ID: 28550915
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Evaluation of synthetic reticular hybrid meshes designed for intraperitoneal abdominal wall repair: Preclinical and in vitro behavior.
    Gómez-Gil V; Rodríguez M; García-Moreno Nisa F; Pérez-Köhler B; Pascual G
    PLoS One; 2019; 14(2):e0213005. PubMed ID: 30811503
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Short-term behavior of different polymer structure lightweight meshes used to repair abdominal wall defects.
    Pascual G; Hernández-Gascón B; Sotomayor S; Peña E; Calvo B; Buján J; Bellón JM
    Histol Histopathol; 2013 May; 28(5):611-21. PubMed ID: 23386547
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Tissue attachment strength and adhesion formation of intraabdominal fixed meshes with cyanoacrylat glues.
    Ladurner R; Drosse I; Seitz S; Plitz W; Barbaryka G; Siebeck M; Bürklein D; Kirchhoff C; Buhman S; Mutschler W; Schieker M; Mussack T
    Eur J Med Res; 2008 May; 13(5):185-91. PubMed ID: 18559298
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Cyanoacrylate for Safer Mesh Fixation During Laparoscopic Repair of Morgagni Hernia.
    Hoyuela C; Juvany M; Guillaumes S
    Ann Thorac Surg; 2020 Apr; 109(4):e305-e307. PubMed ID: 31785292
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Evaluation of adhesion formation, mesh fixation strength, and hydroxyproline content after intraabdominal placement of polytetrafluoroethylene mesh secured using titanium spiral tacks, nitinol anchors, and polypropylene suture or polyglactin 910 suture.
    Joels CS; Matthews BD; Kercher KW; Austin C; Norton HJ; Williams TC; Heniford BT
    Surg Endosc; 2005 Jun; 19(6):780-5. PubMed ID: 15776210
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Cyanoacrylate surgical glue as an alternative to suture threads for mesh fixation in hernia repair.
    Losi P; Burchielli S; Spiller D; Finotti V; Kull S; Briganti E; Soldani G
    J Surg Res; 2010 Oct; 163(2):e53-8. PubMed ID: 20691995
    [TBL] [Abstract][Full Text] [Related]  

  • 28. N-butyl cyanoacrylate versus conventional suturing for fixation of meshes in an incisional hernia model.
    Dilege E; Deveci U; Erbil Y; Dinççağ A; Seven R; Ozarmagan S; Mercan S; Barbaros U
    J Invest Surg; 2010 Oct; 23(5):262-6. PubMed ID: 20874481
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Randomized clinical trial of tissue glue versus absorbable sutures for mesh fixation in local anaesthetic Lichtenstein hernia repair.
    Paajanen H; Kössi J; Silvasti S; Hulmi T; Hakala T
    Br J Surg; 2011 Sep; 98(9):1245-51. PubMed ID: 21710480
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Histologic evaluation of absorbable and non-absorbable barrier coated mesh secured to the peritoneum with fibrin sealant in a New Zealand white rabbit model.
    Jenkins ED; Melman L; Desai S; Deeken CR; Greco SC; Frisella MM; Matthews BD
    Hernia; 2011 Dec; 15(6):677-84. PubMed ID: 21607571
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparative evaluation of adhesion formation, strength of ingrowth, and textile properties of prosthetic meshes after long-term intra-abdominal implantation in a rabbit.
    Novitsky YW; Harrell AG; Cristiano JA; Paton BL; Norton HJ; Peindl RD; Kercher KW; Heniford BT
    J Surg Res; 2007 Jun; 140(1):6-11. PubMed ID: 17481980
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Extraperitoneal and intraperitoneal behavior of several biological meshes currently used to repair abdominal wall defects.
    Pascual G; Sotomayor S; Rodríguez M; Arteaga V; Bellón JM
    J Biomed Mater Res B Appl Biomater; 2015 Feb; 103(2):365-72. PubMed ID: 24895168
    [TBL] [Abstract][Full Text] [Related]  

  • 33. THE USE OF SURGICAL ADHESIVE AND SUTURE FIXING MESHES TO THE ABDOMINAL WALL: AN EXPERIMENTAL STUDY IN RATS.
    Utrabo CAL; Busato CR; Montemór-Netto MR; Lipinski LC; Celinski VR; Ferronato MF; Malafaia O; Koga AY
    Arq Bras Cir Dig; 2022; 35():e1649. PubMed ID: 35730878
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Laparoscopic incisional hernia repair in a porcine model: what do transfixion sutures add?
    Winslow ER; Diaz S; Desai K; Meininger T; Soper NJ; Klingensmith ME
    Surg Endosc; 2004 Mar; 18(3):529-35. PubMed ID: 14752650
    [TBL] [Abstract][Full Text] [Related]  

  • 35. 2-Octyl cyanoacrylate tissue adhesive and muscle attachment to porous anophthalmic orbital implants.
    Gupta BK; Edward D; Duffy MT
    Ophthalmic Plast Reconstr Surg; 2001 Jul; 17(4):264-9. PubMed ID: 11476176
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Mesh fixation in laparoscopic incisional hernia repair: glue fixation provides attachment strength similar to absorbable tacks but differs substantially in different meshes.
    Rieder E; Stoiber M; Scheikl V; Poglitsch M; Dal Borgo A; Prager G; Schima H
    J Am Coll Surg; 2011 Jan; 212(1):80-6. PubMed ID: 21036072
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Biomechanical and histological evaluation of abdominal wall compliance with intraperitoneal onlay mesh implants in rabbits: a comparison of six different state-of-the-art meshes.
    Konerding MA; Chantereau P; Delventhal V; Holste JL; Ackermann M
    Med Eng Phys; 2012 Sep; 34(7):806-16. PubMed ID: 21992970
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparison of a new type of polytetrafluoroethylene patch (Mycro Mesh) and polypropylene prosthesis (Marlex) for repair of abdominal wall defects.
    Bellón JM; Buján J; Contreras LA; Carrera-San Martín A; Jurado F
    J Am Coll Surg; 1996 Jul; 183(1):11-8. PubMed ID: 8673302
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Intraperitoneal tension-free repair of a small midline ventral abdominal wall hernia: randomized study with a mean follow-up of 3 years.
    Bensaadi H; Paolino L; Valenti A; Polliand C; Barrat C; Champault G
    Am Surg; 2014 Jan; 80(1):57-65. PubMed ID: 24401516
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparative Study of Sutureless Fixation of Lightweight Surgical Meshes for Hernia Repair in a Rat Model.
    Anurov MV; Khachatrian GV; Titkova SM; Velangi PS; Polivoda MD; Oettinger AP
    Bull Exp Biol Med; 2017 Oct; 163(6):818-821. PubMed ID: 29063325
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.