These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 27998809)

  • 1. Explaining and reducing the variation in inter-laboratory reported values for International Normalised Ratio.
    Bonar R; Favaloro EJ
    Thromb Res; 2017 Feb; 150():22-29. PubMed ID: 27998809
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Improving the inter-laboratory harmonization of the international normalized ratio (INR): utilizing the concept of transference to estimate and/or validate international sensitivity index (ISI) and mean normal prothrombin time (MNPT) values and/or to eliminate measurement bias.
    Favaloro EJ; McVicker W; Zhang Y; Hamdam S; Huynh M; Peris P; O'Neal M; Hocker N
    Clin Lab Sci; 2012; 25(1):13-25. PubMed ID: 22458045
    [TBL] [Abstract][Full Text] [Related]  

  • 3. International normalized ratio monitoring of vitamin K antagonist therapy: comparative performance of point-of-care and laboratory-derived testing.
    Bonar R; Mohammed S; Favaloro EJ
    Semin Thromb Hemost; 2015 Apr; 41(3):279-86. PubMed ID: 25839866
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Improving the harmonisation of the International Normalized Ratio (INR): time to think outside the box?
    Favaloro EJ; McVicker W; Hamdam S; Hocker N
    Clin Chem Lab Med; 2010 Aug; 48(8):1079-90. PubMed ID: 20441474
    [TBL] [Abstract][Full Text] [Related]  

  • 5. How to Generate a More Accurate Laboratory-Based International Normalized Ratio: Solutions to Obtaining or Verifying the Mean Normal Prothrombin Time and International Sensitivity Index.
    Favaloro EJ
    Semin Thromb Hemost; 2019 Feb; 45(1):10-21. PubMed ID: 30134448
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optimizing the Verification of Mean Normal Prothrombin Time (MNPT) and International Sensitivity Index (ISI) for Accurate Conversion of Prothrombin Time (PT) to International Normalized Ratio (INR).
    Favaloro EJ
    Methods Mol Biol; 2017; 1646():59-74. PubMed ID: 28804818
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [GFHT proposals for management of discordance between the International normalized ratio measured in the laboratory and by self-testing].
    Lasne D; Drouet L; Schved JF; Gruel Y;
    Ann Biol Clin (Paris); 2020 Dec; 78(6):655-664. PubMed ID: 33361016
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Time to think outside the box? Prothrombin time, international normalised ratio, international sensitivity index, mean normal prothrombin time and measurement of uncertainty: a novel approach to standardisation.
    Favaloro EJ; Hamdam S; McDonald J; McVicker W; Ule V
    Pathology; 2008 Apr; 40(3):277-87. PubMed ID: 18428048
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Laboratory Monitoring of Oral Vitamin K Anticoagulation.
    Moffat KA; Lewis CW
    Semin Thromb Hemost; 2017 Apr; 43(3):245-252. PubMed ID: 27677177
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The international normalized ratio according to Owren in liver disease: interlaboratory assessment and determination of international sensitivity index.
    Magnusson M; Sten-Linder M; Bergquist A; Rajani R; Kechagias S; Fischler B; Németh A; Lindahl TL
    Thromb Res; 2013 Sep; 132(3):346-51. PubMed ID: 23993902
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Mathematical derivative applied to international normalised ratio and analytical variations in oral anticoagulant therapy control.
    Introcaso G; Cuboni A; Ratto A; Foieni F
    Haemostasis; 2000; 30(6):281-9. PubMed ID: 11356996
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Standardization of the INR: how good is your laboratory's INR and can it be improved?
    Favaloro EJ; Adcock DM
    Semin Thromb Hemost; 2008 Oct; 34(7):593-603. PubMed ID: 19085760
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Standardization of Prothrombin Time/International Normalized Ratio (PT/INR).
    Dorgalaleh A; Favaloro EJ; Bahraini M; Rad F
    Int J Lab Hematol; 2021 Feb; 43(1):21-28. PubMed ID: 32979036
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Monitoring anticoagulant therapy with vitamin K antagonists in patients with antiphospholipid syndrome.
    Isert M; Miesbach W; Schüttfort G; Weil Y; Tirneci V; Kasper A; Weber A; Lindhoff-Last E; Herrmann E; Linnemann B
    Ann Hematol; 2015 Aug; 94(8):1291-9. PubMed ID: 25859986
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A modified method of prothrombin time/International Normalised Ratio determination in capillary blood and monitoring oral anticoagulant therapy.
    Berkovsky A; Sergeeva EV; Suvorov AV; Uljavova IS; Kachalova ND; Klimovich LG; Samsonova NN; Kozlov AA
    Clin Chem Lab Med; 2006; 44(10):1214-7. PubMed ID: 17032133
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of warfarin management with international normalized ratio self-testing and online remote monitoring and management plus low-dose vitamin k with genomic considerations: a pilot study.
    Bussey HI; Bussey M; Bussey-Smith KL; Frei CR
    Pharmacotherapy; 2013 Nov; 33(11):1136-46. PubMed ID: 24038412
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of frozen plasma calibrants for enhanced standardization of the international normalized ratio (INR): a multi-center study.
    Adcock DM; Johnston M
    Thromb Haemost; 2002 Jan; 87(1):74-9. PubMed ID: 11848460
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Establishing an external quality assessment scheme for point-of-care international normalized ratio in Thailand.
    Tientadakul P; Chuntarut A
    Int J Lab Hematol; 2015 Aug; 37(4):509-14. PubMed ID: 25529559
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Accuracy of point of care coagulometers compared to reference laboratory measurements in patients on oral anticoagulation therapy.
    Dillinger JG; Si Moussi T; Berge N; Bal Dit Sollier C; Henry P; Drouet L
    Thromb Res; 2016 Apr; 140():66-72. PubMed ID: 26901852
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Harmonizing the International Normalized Ratio (INR) : Standardization of Methods and Use of Novel Strategies to Reduce Interlaboratory Variation and Bias.
    Favaloro EJ; McVicker W; Lay M; Ahuja M; Zhang Y; Hamdam S; Hocker N
    Am J Clin Pathol; 2016 Feb; 145(2):191-202. PubMed ID: 26800763
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.