These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

193 related articles for article (PubMed ID: 28009715)

  • 1. Impact of LVAD Implantation Site on Ventricular Blood Stagnation.
    Prisco AR; Aliseda A; Beckman JA; Mokadam NA; Mahr C; Garcia GJM
    ASAIO J; 2017; 63(4):392-400. PubMed ID: 28009715
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The influence of left ventricular assist device inflow cannula position on thrombosis risk.
    Ghodrati M; Maurer A; Schlöglhofer T; Khienwad T; Zimpfer D; Beitzke D; Zonta F; Moscato F; Schima H; Aigner P
    Artif Organs; 2020 Sep; 44(9):939-946. PubMed ID: 32302423
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Reducing regional flow stasis and improving intraventricular hemodynamics with a tipless inflow cannula design: An in vitro flow visualization study using the EVAHEART LVAD.
    May-Newman K; Montes R; Campos J; Marquez-Maya N; Vu V; Zebrowski E; Motomura T; Benkowski R
    Artif Organs; 2019 Sep; 43(9):834-848. PubMed ID: 31038753
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Left Ventricular Assist Device Inflow Cannula Angle and Thrombosis Risk.
    Chivukula VK; Beckman JA; Prisco AR; Dardas T; Lin S; Smith JW; Mokadam NA; Aliseda A; Mahr C
    Circ Heart Fail; 2018 Apr; 11(4):e004325. PubMed ID: 29666072
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Proposing a novel technique to exclude the left ventricle with an assist device: insights from 4-dimensional flow magnetic resonance imaging.
    Klotz S; Meyer-Saraei R; Frydrychowicz A; Scharfschwerdt M; Putman LM; Halder S; Sievers HH
    Eur J Cardiothorac Surg; 2016 Sep; 50(3):439-45. PubMed ID: 27107046
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Computational fluid dynamics analysis of surgical adjustment of left ventricular assist device implantation to minimise stroke risk.
    Osorio AF; Osorio R; Ceballos A; Tran R; Clark W; Divo EA; Argueta-Morales IR; Kassab AJ; DeCampli WM
    Comput Methods Biomech Biomed Engin; 2013; 16(6):622-38. PubMed ID: 22185643
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Computational analysis of thrombosis risk with variations in left ventricular assist device inflow cannula design in a multi-patient model.
    Khamooshi M; Azimi M; Gregory SD
    Comput Methods Programs Biomed; 2023 Oct; 240():107730. PubMed ID: 37531687
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impact of aortic valve closure on adverse events and outcomes with the HeartWare ventricular assist device.
    Dobarro D; Urban M; Booth K; Wrightson N; Castrodeza J; Jungschleger J; Robinson-Smith N; Woods A; Parry G; Schueler S; MacGowan GA
    J Heart Lung Transplant; 2017 Jan; 36(1):42-49. PubMed ID: 27776988
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Intermittent Aortic Valve Opening and Risk of Thrombosis in Ventricular Assist Device Patients.
    Mahr C; Chivukula VK; McGah P; Prisco AR; Beckman JA; Mokadam NA; Aliseda A
    ASAIO J; 2017; 63(4):425-432. PubMed ID: 28118265
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Numerical study of the effect of LVAD inflow cannula positioning on thrombosis risk.
    He G; Han L; Zhang J; Shah A; Kaczorowski DJ; Griffith BP; Wu Z
    Comput Methods Biomech Biomed Engin; 2022 Jun; 25(8):852-860. PubMed ID: 34592878
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Aortic insufficiency in patients with sustained left ventricular systolic dysfunction after axial flow assist device implantation.
    Imamura T; Kinugawa K; Fujino T; Inaba T; Maki H; Hatano M; Kinoshita O; Nawata K; Kyo S; Ono M
    Circ J; 2015; 79(1):104-11. PubMed ID: 25381791
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ventricular assist device thrombosis following recovery of left ventricular function.
    Sifain AR; Schwarz KQ; Hallinan W; Massey HT; Alexis JD
    ASAIO J; 2014; 60(2):243-5. PubMed ID: 24469296
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Left Ventricular Assist Device Inflow Cannula Insertion Depth Influences Thrombosis Risk.
    Chivukula VK; Beckman JA; Li S; Masri SC; Levy WC; Lin S; Cheng RK; Farris SD; Wood G; Dardas TF; Kirkpatrick JN; Koomalsingh K; Zimpfer D; Mackensen GB; Chassagne F; Mahr C; Aliseda A
    ASAIO J; 2020 Jul; 66(7):766-773. PubMed ID: 31453832
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A Computational Investigation of the Effects of Temporal Synchronization of Left Ventricular Assist Device Speed Modulation with the Cardiac Cycle on Intraventricular Hemodynamics.
    Straccia A; Chassagne F; Barbour MC; Beckman J; Li S; Mahr C; Aliseda A
    Ann Biomed Eng; 2024 Jun; 52(6):1763-1778. PubMed ID: 38517620
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Aortic root thrombosis leading to STEMI in a Heartmate 3 patient.
    Ilonze OJ; Torabi A; Guglin M; Saleem K; Rao R
    J Artif Organs; 2023 Mar; 26(1):73-78. PubMed ID: 35604615
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Numerical characterization of hemodynamics conditions near aortic valve after implantation of Left Ventricular Assist Device.
    Quaini A; Canić S; Paniagua D
    Math Biosci Eng; 2011 Jul; 8(3):785-806. PubMed ID: 21675811
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Opening of Aortic Valve During Exercise Is Key to Preventing Development of Aortic Insufficiency During Ventricular Assist Device Treatment.
    Imamura T; Kinugawa K; Nitta D; Hatano M; Ono M
    ASAIO J; 2015; 61(5):514-9. PubMed ID: 25955152
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pathology in patients with ventricular assist devices: a study of 21 autopsies, 24 ventricular apical core biopsies and 24 explanted hearts.
    Rose AG; Park SJ
    Cardiovasc Pathol; 2005; 14(1):19-23. PubMed ID: 15710287
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Left ventricular mobile thrombus associated with ventricular assist device: diagnosis by transesophageal echocardiography.
    Miyake Y; Sugioka K; Bussey CD; Di Tullio M; Homma S
    Circ J; 2004 Apr; 68(4):383-4. PubMed ID: 15056839
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Computational fluid dynamic study of hemodynamic effects on aortic root blood flow of systematically varied left ventricular assist device graft anastomosis design.
    Callington A; Long Q; Mohite P; Simon A; Mittal TK
    J Thorac Cardiovasc Surg; 2015 Sep; 150(3):696-704. PubMed ID: 26092505
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.