323 related articles for article (PubMed ID: 28012722)
1. Femoral Implant Design Modification Decreases the Incidence of Patellar Crepitus in Total Knee Arthroplasty.
Martin JR; Jennings JM; Watters TS; Levy DL; McNabb DC; Dennis DA
J Arthroplasty; 2017 Apr; 32(4):1310-1313. PubMed ID: 28012722
[TBL] [Abstract][Full Text] [Related]
2. Comparison Between the Attune and PFC Sigma in Total Knee Arthroplasty: No Difference in Patellar Clunk and Crepitus or Anterior Knee Pain.
Bateman DK; Preston JS; Mennona S; Gui E; Kayiaros S
Orthopedics; 2020 Nov; 43(6):e508-e514. PubMed ID: 32818287
[TBL] [Abstract][Full Text] [Related]
3. Influence of femoral implant design modification on anterior knee pain and patellar crepitus in patients who underwent total knee arthroplasty without patella resurfacing.
Huang YF; Gao YH; Ding L; Liu B; Liu JG; Qi X
BMC Musculoskelet Disord; 2020 Jun; 21(1):364. PubMed ID: 32517681
[TBL] [Abstract][Full Text] [Related]
4. Resurfacing in a Posterior-Stabilized Total Knee Arthroplasty Reduces Patellar Crepitus Complication: A Randomized, Controlled Trial.
Thiengwittayaporn S; Srungboonmee K; Chiamtrakool B
J Arthroplasty; 2019 Sep; 34(9):1969-1974. PubMed ID: 31126775
[TBL] [Abstract][Full Text] [Related]
5. Effect of Patellar Resurfacing on Patellofemoral Crepitus in Posterior-Stabilized Total Knee Arthroplasty.
Ogawa H; Matsumoto K; Akiyama H
J Arthroplasty; 2016 Aug; 31(8):1792-6. PubMed ID: 26948175
[TBL] [Abstract][Full Text] [Related]
6. Implant Design and Effects on Patellofemoral Crepitus.
McNabb DC; Dennis DA; Jennings JM; Daines B; Laz P; Kim RH
J Knee Surg; 2017 Nov; 30(9):863-871. PubMed ID: 28114703
[No Abstract] [Full Text] [Related]
7. Clinical and Radiographic Results of Attune and PFC Sigma Knee Designs at 2-Year Follow-Up: A Prospective Matched-Pair Analysis.
Ranawat CS; White PB; West S; Ranawat AS
J Arthroplasty; 2017 Feb; 32(2):431-436. PubMed ID: 27600300
[TBL] [Abstract][Full Text] [Related]
8. Modern implants in total knee arthroplasty are more patellofemoral joint friendly compared to their traditional design: a systematic review and meta-analysis.
Choudhury AK; Gupta K; Ansari S; Raja BS; Paul S; Kalia RB
Arch Orthop Trauma Surg; 2023 Sep; 143(9):5873-5889. PubMed ID: 36961568
[TBL] [Abstract][Full Text] [Related]
9. Modern femoral component design in total knee arthroplasty shows a lower patellar contact force during knee flexion compared with its predecessor.
Nakano N; Kuroda Y; Maeda T; Takayama K; Hashimoto S; Ishida K; Hayashi S; Hoshino Y; Matsushita T; Niikura T; Kuroda R; Matsumoto T
Knee; 2021 Jun; 30():1-8. PubMed ID: 33784535
[TBL] [Abstract][Full Text] [Related]
10. The John Insall Award: control-matched evaluation of painful patellar Crepitus after total knee arthroplasty.
Dennis DA; Kim RH; Johnson DR; Springer BD; Fehring TK; Sharma A
Clin Orthop Relat Res; 2011 Jan; 469(1):10-7. PubMed ID: 20706813
[TBL] [Abstract][Full Text] [Related]
11. Effect of femoral component design on patellofemoral crepitance and patella clunk syndrome after posterior-stabilized total knee arthroplasty.
Frye BM; Floyd MW; Pham DC; Feldman JJ; Hamlin BR
J Arthroplasty; 2012 Jun; 27(6):1166-70. PubMed ID: 22285232
[TBL] [Abstract][Full Text] [Related]
12. The Evolution of Implant Design Decreases the Incidence of Lateral Release in Primary Total Knee Arthroplasty.
Webb JE; Yang HY; Collins JE; Losina E; Thornhill TS; Katz JN
J Arthroplasty; 2017 May; 32(5):1505-1509. PubMed ID: 28089467
[TBL] [Abstract][Full Text] [Related]
13. Do Changes in Patellofemoral Joint Offset Lead to Adverse Outcomes in Total Knee Arthroplasty With Patellar Resurfacing? A Radiographic Review.
Matz J; Howard JL; Morden DJ; MacDonald SJ; Teeter MG; Lanting BA
J Arthroplasty; 2017 Mar; 32(3):783-787.e1. PubMed ID: 27720514
[TBL] [Abstract][Full Text] [Related]
14. Total knee implant posterior stabilised by a third condyle: Design evolution and post-operative complications.
Gaillard R; Lustig S; Peltier A; Villa V; Servien E; Neyret P
Orthop Traumatol Surg Res; 2016 Dec; 102(8):1061-1068. PubMed ID: 27771429
[TBL] [Abstract][Full Text] [Related]
15. Patellofemoral design enhancements reduce long-term complications of postero-stabilized total knee arthroplasty.
Jan N; Fontaine C; Migaud H; Pasquier G; Valluy J; Saffarini M; Putman S
Knee Surg Sports Traumatol Arthrosc; 2019 Apr; 27(4):1241-1250. PubMed ID: 30203198
[TBL] [Abstract][Full Text] [Related]
16. In Vivo Three-Dimensional Patellar Mechanics: Normal Knees Compared with Domed and Anatomic Patellar Components.
Sharma A; Grieco TF; Zingde SM; Dennis DA; Anderle MR; Komistek RD
J Bone Joint Surg Am; 2017 Mar; 99(5):e18. PubMed ID: 28244917
[TBL] [Abstract][Full Text] [Related]
17. Comparison of Patellofemoral Outcomes between Attune and PFC Sigma Designs: A Prospective Matched-Pair Analysis.
Maniar RN; Bhatnagar N; Bidwai R; Dhiman A; Chanda D; Sanghavi N
Clin Orthop Surg; 2022 Mar; 14(1):96-104. PubMed ID: 35251546
[TBL] [Abstract][Full Text] [Related]
18. Impingement of the patellar component against the tibial post depends on the design of the post-cam mechanism: Comparison between 12 posterior stabilized total knee prostheses.
Minoda Y; Sugama R; Ohta Y; Ikebuchi M; Nakamura H
Knee; 2018 Aug; 25(4):676-681. PubMed ID: 29884561
[TBL] [Abstract][Full Text] [Related]
19. Comparison of Patellofemoral-Specific Clinical and Radiographic Results after Total Knee Arthroplasty Using a Patellofemoral Design-Modified Prosthesis and Its Predecessor.
Song SJ; Kim KI; Suh DU; Park CH
Clin Orthop Surg; 2021 Jun; 13(2):175-184. PubMed ID: 34094008
[TBL] [Abstract][Full Text] [Related]
20. Evaluation of anterior knee pain in a PS total knee arthroplasty: the role of patella-friendly femoral component and patellar size.
Atzori F; Sabatini L; Deledda D; Schirò M; Lo Baido R; Massè A
Musculoskelet Surg; 2015 Apr; 99(1):75-83. PubMed ID: 25672918
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]