These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. [Effect of prosthesis type and size on the hemodynamic response of mitral valve prostheses to exertion]. Alonso AM; Belló MC Rev Med Univ Navarra; 1996; 40(3):19-26. PubMed ID: 9499822 [TBL] [Abstract][Full Text] [Related]
3. Analysis of Doppler-obtained velocity curves in functional evaluation of mechanical prosthetic valves in the mitral and aortic positions. Goldrath N; Zimes R; Vered Z J Am Soc Echocardiogr; 1988; 1(3):211-25. PubMed ID: 3272769 [TBL] [Abstract][Full Text] [Related]
4. [Hemodynamic evaluation of GK and Medtronic-Hall prosthetic mitral valves by exercise Doppler echocardiography]. Fan CM Zhonghua Xin Xue Guan Bing Za Zhi; 1992 Dec; 20(6):335-7, 388. PubMed ID: 1307966 [TBL] [Abstract][Full Text] [Related]
5. Detection of "pathologic" prosthetic valve stenosis via exercise Doppler echocardiography. Shigenobu M; Sano S Heart Vessels; 1995; 10(1):35-40. PubMed ID: 7730245 [TBL] [Abstract][Full Text] [Related]
6. Doppler hemodynamic evaluation of prosthetic (Starr-Edwards and Björk-Shiley) and bioprosthetic (Hancock and Carpentier-Edwards) cardiac valves. Williams GA; Labovitz AJ Am J Cardiol; 1985 Aug; 56(4):325-32. PubMed ID: 4025173 [TBL] [Abstract][Full Text] [Related]
7. Doppler echocardiographic evaluation of normal and thrombosed Björk-Shiley mitral prosthetic valves. Radhakrishnan S; Behl VK; Bajaj R; Bhatia ML; Shrivastava S Int J Cardiol; 1988 Sep; 20(3):387-93. PubMed ID: 3170040 [TBL] [Abstract][Full Text] [Related]
8. [Doppler echocardiography in assessing mechanical and biological heart valve prostheses]. Minardi G; Di Segni M; Boccardi L; Ferrari O; Giovannini E G Ital Cardiol; 1988 Feb; 18(2):121-34. PubMed ID: 3410201 [TBL] [Abstract][Full Text] [Related]
9. Normal and abnormal prosthetic valve function as assessed by Doppler echocardiography. Panidis IP; Ross J; Mintz GS J Am Coll Cardiol; 1986 Aug; 8(2):317-26. PubMed ID: 2942593 [TBL] [Abstract][Full Text] [Related]
10. [Doppler echocardiographic evaluation of the new mechanical bileaflet Sorin Bicarbon valve prosthesis compared with St. Jude Medical]. Badano L; Carratino L; De Gaetano G; Piazza R; Calisi P; Passerone G; Lucatti A G Ital Cardiol; 1994 Jun; 24(6):733-43. PubMed ID: 8088472 [TBL] [Abstract][Full Text] [Related]
11. Hemodynamic evaluation of the Monostrut and spherical disc Björk-Shiley aortic valve prosthesis with Doppler echocardiography. Kenny A; Woods J; Fuller CA; Sharples L; Stone DL; Wells FC; Shapiro LM J Thorac Cardiovasc Surg; 1992 Oct; 104(4):1025-8. PubMed ID: 1405659 [TBL] [Abstract][Full Text] [Related]
12. Hemodynamic evaluation of bovine pericardial xenograft valves in the mitral position by stress Doppler echocardiography. Fan CM; Tao SQ; Liu HY; Hu BL; Yang HY; Zhu XD Chin Med J (Engl); 1993 Jan; 106(1):40-4. PubMed ID: 8504681 [TBL] [Abstract][Full Text] [Related]
14. Rest and exercise evaluation of St. Jude Medical and Medtronic Hall prostheses. Influence of primary lesion, valvular type, valvular size, and left ventricular function. Tatineni S; Barner HB; Pearson AC; Halbe D; Woodruff R; Labovitz AJ Circulation; 1989 Sep; 80(3 Pt 1):I16-23. PubMed ID: 2766522 [TBL] [Abstract][Full Text] [Related]
15. Functional impact of transmitral gradients at rest and during exercise after restrictive annuloplasty for ischemic mitral regurgitation. Bertrand PB; Gutermann H; Smeets CJ; Van Kerrebroeck C; Verhaert D; Vandervoort P; Dion R J Thorac Cardiovasc Surg; 2014 Jul; 148(1):183-7. PubMed ID: 24332186 [TBL] [Abstract][Full Text] [Related]
16. Central hemodynamics at rest and during exercise after mitral valve replacement with different prostheses. Horstkotte D; Haerten K; Seipel L; Körfer R; Budde T; Bircks W; Loogen F Circulation; 1983 Sep; 68(3 Pt 2):II161-8. PubMed ID: 6872188 [TBL] [Abstract][Full Text] [Related]
17. [Usefulness of exercise Doppler in the diagnosis of severe mitral stenosis]. Alonso Gómez AM; Belló Mora MC; Arós Borau F; Torres Bosco A; Martínez Ferrer JB; Camacho Azcargorta I Rev Esp Cardiol; 1997 Feb; 50(2):98-104. PubMed ID: 9092009 [TBL] [Abstract][Full Text] [Related]
18. Evaluation of normal hemodynamic profile of CarboMedics prosthetic valves by Doppler echocardiography. Chakraborty B; Quek S; Pin DZ; Siong CT; Kheng TL Angiology; 1997 Dec; 48(12):1055-61. PubMed ID: 9404832 [TBL] [Abstract][Full Text] [Related]
19. Rest and exercise hemodynamics of 20 to 23 mm allograft, Medtronic Intact (porcine), and St. Jude Medical valves in the aortic position. Jaffe WM; Coverdale HA; Roche AH; Whitlock RM; Neutze JM; Barratt-Boyes BG J Thorac Cardiovasc Surg; 1990 Aug; 100(2):167-74. PubMed ID: 2385114 [TBL] [Abstract][Full Text] [Related]
20. [Doppler echocardiography normal values in various types of mitral valve prostheses]. Curtius JM; Pawelzik H; Mittmann B; Breuer HW; Loogen F Z Kardiol; 1987 Jan; 76(1):25-9. PubMed ID: 3564614 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]