These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 2801526)

  • 1. Usefulness of the Doppler mean gradient in evaluation of children with aortic valve stenosis and comparison to gradient at catheterization.
    Bengur AR; Snider AR; Serwer GA; Peters J; Rosenthal A
    Am J Cardiol; 1989 Oct; 64(12):756-61. PubMed ID: 2801526
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Correction of Doppler Gradients for Pressure Recovery Improves Agreement with Subsequent Catheterization Gradients in Congenital Aortic Stenosis.
    Schlingmann TR; Gauvreau K; Colan SD; Powell AJ
    J Am Soc Echocardiogr; 2015 Dec; 28(12):1410-7. PubMed ID: 26454341
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of aortic stenosis severity: role of contrast echocardiography in comparison with conventional echocardiography and cardiac catheterization.
    Almeida AG; Sargento L; Gabriel HM; da Costa JM; Morais J; Madeira F; David C; Oliveira J; da Cunha JC; Vagueiro MC
    Rev Port Cardiol; 2002 May; 21(5):555-72. PubMed ID: 12174519
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Noninvasive quantification and classification of the severity of aortic stenosis using Doppler echocardiography].
    Schmalz A; Erbel R; Wittlich N; Mohr-Kahaly S; Meyer J
    Z Kardiol; 1992 Nov; 81(11):619-26. PubMed ID: 1471399
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Practical value of echo Doppler evaluation of aortic and mitral stenosis: a comparative study with cardiac catheterization.
    Bitar J; Douthat L; Alam M; Rosman HS; Lebeis M; Goldstein S; Khaja F
    Henry Ford Hosp Med J; 1990; 38(1):87-90. PubMed ID: 2228721
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Systematic correlation of continuous-wave Doppler and hemodynamic measurements in patients with aortic stenosis.
    Smith MD; Dawson PL; Elion JL; Wisenbaugh T; Kwan OL; Handshoe S; DeMaria AN
    Am Heart J; 1986 Feb; 111(2):245-52. PubMed ID: 3511648
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A reconsideration of Doppler assessed gradients in suspected aortic stenosis.
    Krafchek J; Robertson JH; Radford M; Adams D; Kisslo J
    Am Heart J; 1985 Oct; 110(4):765-73. PubMed ID: 4050648
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of Doppler-derived pressure gradient to that determined at cardiac catheterization in adults with aortic valve stenosis: implications for management.
    Yeager M; Yock PG; Popp RL
    Am J Cardiol; 1986 Mar; 57(8):644-8. PubMed ID: 3953450
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quantification of aortic stenosis in mechanically ventilated patients using multiplane transesophageal Doppler echocardiography.
    Blumberg FC; Pfeifer M; Holmer SR; Kromer EP; Riegger GA; Elsner D
    Chest; 1998 Jul; 114(1):94-7. PubMed ID: 9674453
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Diastolic velocity half time is associated with aortic coarctation gradient at catheterization independent of echocardiographic and clinical blood pressure gradients.
    Christopher AB; Apfel A; Sun T; Kreutzer J; Ezon DS
    Congenit Heart Dis; 2018 Sep; 13(5):713-720. PubMed ID: 30395387
    [TBL] [Abstract][Full Text] [Related]  

  • 11. "Overestimation" of catheter gradients by Doppler ultrasound in patients with aortic stenosis: a predictable manifestation of pressure recovery.
    Baumgartner H; Stefenelli T; Niederberger J; Schima H; Maurer G
    J Am Coll Cardiol; 1999 May; 33(6):1655-61. PubMed ID: 10334438
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of catheterization and Doppler-derived pressure gradients in a canine model of subaortic stenosis.
    Lehmkuhl LB; Bonagura JD; Jones DE; Stepien RL
    J Am Soc Echocardiogr; 1995; 8(5 Pt 1):611-20. PubMed ID: 9417203
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Correlation of continuous wave Doppler velocities with cardiac catheterization gradients: an experimental model of aortic stenosis.
    Smith MD; Dawson PL; Elion JL; Booth DC; Handshoe R; Kwan OL; Earle GF; DeMaria AN
    J Am Coll Cardiol; 1985 Dec; 6(6):1306-14. PubMed ID: 3905918
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Echocardiographic follow-up of congenital aortic valvular stenosis.
    Eroglu AG; Babaoglu K; Saltik L; Oztunç F; Demir T; Ahunbay G; Guzeltas A; Cetin G
    Pediatr Cardiol; 2006; 27(6):713-9. PubMed ID: 17111293
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Doppler echocardiographic estimation of the pressure gradient in aortic stenosis. An updated assessment of the technique used in clinical practice in 249 patients.
    Schroeder AP; Egeblad H; Kristensen BO
    Cardiology; 1996; 87(6):545-51. PubMed ID: 8904684
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Instantaneous pressure gradient: a simultaneous Doppler and dual catheter correlative study.
    Currie PJ; Hagler DJ; Seward JB; Reeder GS; Fyfe DA; Bove AA; Tajik AJ
    J Am Coll Cardiol; 1986 Apr; 7(4):800-6. PubMed ID: 3958336
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Clinical utility of Doppler echocardiography in assessing aortic stenosis severity and predicting need for intervention in children.
    Vlahos AP; Marx GR; McElhinney D; Oneill S; Goudevenos I; Colan SD
    Pediatr Cardiol; 2008 May; 29(3):507-14. PubMed ID: 18080153
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Continuous-wave Doppler echocardiographic assessment of severity of calcific aortic stenosis: a simultaneous Doppler-catheter correlative study in 100 adult patients.
    Currie PJ; Seward JB; Reeder GS; Vlietstra RE; Bresnahan DR; Bresnahan JF; Smith HC; Hagler DJ; Tajik AJ
    Circulation; 1985 Jun; 71(6):1162-9. PubMed ID: 3995710
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The Functional Significance of Paradoxical Low-Gradient Aortic Valve Stenosis: Hemodynamic Findings During Cardiopulmonary Exercise Testing.
    Pérez Del Villar C; Yotti R; Espinosa MÁ; Gutiérrez-Ibañes E; Barrio A; Lorenzo MJ; Sánchez Fernández PL; Benito Y; Prieto R; Pérez David E; Martínez-Legazpi P; Fernández-Avilés F; Bermejo J
    JACC Cardiovasc Imaging; 2017 Jan; 10(1):29-39. PubMed ID: 27568118
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Determination of severity of valvular aortic stenosis by Doppler echocardiography and relation of findings to clinical outcome and agreement with hemodynamic measurements determined at cardiac catheterization.
    Galan A; Zoghbi WA; Quiñones MA
    Am J Cardiol; 1991 May; 67(11):1007-12. PubMed ID: 2018003
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.