136 related articles for article (PubMed ID: 28025752)

  • 1. Sound level analysis in endotracheal tube obstruction in spontaneous breathing and mechanical ventilation-an animal model study.
    Maghsoodi B; Sabetian G; Azimi A; Tanideh N; Mehdizade A
    J Clin Monit Comput; 2017 Dec; 31(6):1235-1240. PubMed ID: 28025752
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Detection of endotracheal tube obstruction by analysis of the expiratory flow signal.
    Guttmann J; Eberhard L; Haberthür C; Mols G; Kessler V; Lichtwarck-Aschoff M; Geiger K
    Intensive Care Med; 1998 Nov; 24(11):1163-72. PubMed ID: 9876979
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Sound analysis in an in vitro endotracheal tube model.
    Park YS; Kee YW; Park KS; Lee J; Lee SM; Yim JJ; Yoo CG; Kim YW; Han SK; Yang SC
    Korean J Intern Med; 2011 Dec; 26(4):421-6. PubMed ID: 22205842
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Gradual reduction of endotracheal tube diameter during mechanical ventilation via different humidification devices.
    Villafane MC; Cinnella G; Lofaso F; Isabey D; Harf A; Lemaire F; Brochard L
    Anesthesiology; 1996 Dec; 85(6):1341-9. PubMed ID: 8968181
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Acoustic method to estimate the longitudinal area profile of endotracheal tubes.
    Van Surell C; Louis B; Lofaso F; Beydon L; Brochard L; Harf A; Fredberg J; Isabey D
    Am J Respir Crit Care Med; 1994 Jan; 149(1):28-33. PubMed ID: 8111593
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Electron microscopic analysis of biofilm on tracheal tubes removed from intubated neonates and the relationship between bilofilm and lower respiratory infection].
    Chen BM; Yu JL; Liu GX; Hu LY; Li LQ; Li F; Yang H
    Zhonghua Er Ke Za Zhi; 2007 Sep; 45(9):655-60. PubMed ID: 18021554
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Miniature acoustic guidance system for endotracheal tubes.
    Juan EJ; Mansfield JP; Wodicka GR
    IEEE Trans Biomed Eng; 2002 Jun; 49(6):584-96. PubMed ID: 12046704
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of Endotracheal Tube Scraping on Airway Resistance.
    Scott JB; Dubosky MN; Vines DL; Sulaiman AS; Jendral KR; Singh G; Patel A; Kaplan CA; Gurka DP; Balk RA
    Respir Care; 2017 Nov; 62(11):1423-1427. PubMed ID: 28790149
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Change in expiratory flow detects partial endotracheal tube obstruction in pressure-controlled ventilation.
    Kawati R; Vimlati L; Guttmann J; Hedenstierna G; Sjöstrand U; Schumann S; Lichtwarck-Aschoff M
    Anesth Analg; 2006 Sep; 103(3):650-7. PubMed ID: 16931676
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Endotracheal tube intraluminal diameter narrowing after mechanical ventilation: use of acoustic reflectometry.
    Boqué MC; Gualis B; Sandiumenge A; Rello J
    Intensive Care Med; 2004 Dec; 30(12):2204-9. PubMed ID: 15580475
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Acute obstruction of the endotracheal tube].
    Steinmann D; Priebe HJ; Guttmann J
    Anaesthesist; 2008 Mar; 57(3):251-4. PubMed ID: 18256804
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Detection of partial endotracheal tube obstruction by forced pressure oscillations.
    Schumann S; Lichtwarck-Aschoff M; Haberthür C; Stahl CA; Möller K; Guttmann J
    Respir Physiol Neurobiol; 2007 Mar; 155(3):227-33. PubMed ID: 16861058
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Detection of positional airway obstruction in neonates by acoustic reflection.
    Jarreau PH; Louis B; Desfrère L; Blanchard PW; Isabey D; Harf A; Moriette G
    Am J Respir Crit Care Med; 2000 May; 161(5):1754-6. PubMed ID: 10806183
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A new device to remove obstruction from endotracheal tubes during mechanical ventilation in critically ill patients.
    Conti G; Rocco M; De Blasi RA; Lappa A; Antonelli M; Bufi M; Gasparetto A
    Intensive Care Med; 1994 Nov; 20(8):573-6. PubMed ID: 7706570
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Removal of endotracheal tube obstruction with a secretion clearance device.
    Mietto C; Foley K; Salerno L; Oleksak J; Pinciroli R; Goverman J; Berra L
    Respir Care; 2014 Sep; 59(9):e122-6. PubMed ID: 24368863
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Acoustic method to quantitatively assess the position and patency of infant endotracheal tubes: preliminary results in rabbits.
    Mansfield JP; Shannon DC; Wodicka GR
    Pediatr Pulmonol; 1998 Nov; 26(5):354-61. PubMed ID: 9859906
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Contribution of the endotracheal tube and the upper airway to breathing workload.
    Straus C; Louis B; Isabey D; Lemaire F; Harf A; Brochard L
    Am J Respir Crit Care Med; 1998 Jan; 157(1):23-30. PubMed ID: 9445274
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Breath sound changes associated with malpositioned endotracheal tubes.
    Mansy HA; O'Connor CJ; Balk RA; Sandler RH
    Med Biol Eng Comput; 2005 Mar; 43(2):206-11. PubMed ID: 15865129
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Endotracheal Tube Obstruction Among Patients Mechanically Ventilated for ARDS Due to COVID-19: A Case Series.
    Wiles S; Mireles-Cabodevila E; Neuhofs S; Mukhopadhyay S; Reynolds JP; Hatipoğlu U
    J Intensive Care Med; 2021 May; 36(5):604-611. PubMed ID: 33375893
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Changes in resistances of endotracheal tubes with reductions in the cross-sectional area.
    El-Khatib MF; Husari A; Jamaleddine GW; Ayoub CM; Bou-Khalil P
    Eur J Anaesthesiol; 2008 Apr; 25(4):275-9. PubMed ID: 18177540
    [TBL] [Abstract][Full Text] [Related]  