  • 1. Managing glaucoma drainage device tube leak with cyanoacrylate.
    Kusabara AA; Kasahara N
    Acta Ophthalmol; 2017 Nov; 95(7):e662. PubMed ID: 28029228
    [No Abstract]   [Full Text] [Related]  

  • 2. The use of nonabsorbable suture ligatures for glaucoma drainage devices.
    Moura Filho ER; Sit AJ
    Arch Ophthalmol; 2010 May; 128(5):624-7. PubMed ID: 20457986
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Complications in Placement of a Glaucoma Drainage Device in a Patient With CREST Syndrome.
    Husain MQ; Alsheikh O
    J Glaucoma; 2017 Feb; 26(2):e82-e83. PubMed ID: 27811572
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Late bleb leak management with trabeculectomy shutdown, Baerveldt glaucoma device implantation, and titratable tube lumen size.
    Miller G; Tam DY; Ahmed II
    J Glaucoma; 2011 Jan; 20(1):51-6. PubMed ID: 20436369
    [TBL] [Abstract][Full Text] [Related]  

  • 5. August consultation #7.
    Barnebey H
    J Cataract Refract Surg; 2018 Aug; 44(8):1053-1054. PubMed ID: 30115286
    [No Abstract]   [Full Text] [Related]  

  • 6. Internal glaucoma drainage device tube fenestration for uncontrolled postoperative intraocular pressure.
    Campbell RJ; Buys YM; McIlraith IP; Trope GE
    J Glaucoma; 2008 Sep; 17(6):494-6. PubMed ID: 18794687
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Repositioning of Ahmed glaucoma valve tube in the anterior chamber with prolene sutures to manage tube-endothelial touch.
    Dada T; Gupta R; Tinwala SI; Sobti A; Panda A
    Nepal J Ophthalmol; 2012; 4(2):309-11. PubMed ID: 22864039
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Obstruction of the Ex-PRESS miniature glaucoma device: Nd: YAG laser as a therapeutic option.
    Bagnis A; Papadia M; Scotto R; Traverso CE
    J Glaucoma; 2011; 20(4):271. PubMed ID: 21430552
    [No Abstract]   [Full Text] [Related]  

  • 9. Obstruction (also known as occlusion or blockage) of the Ex-PRESS miniature glaucoma device.
    Netland PA
    J Glaucoma; 2011; 20(4):271-2. PubMed ID: 21430551
    [No Abstract]   [Full Text] [Related]  

  • 10. A Case Report of Complete Blockage of a Baerveldt Glaucoma Implant Following Insertion of a 3-0 Supramid Suture.
    Lee RMH; Bouremel Y; Eames I; Brocchini S; Khaw PT
    J Glaucoma; 2019 May; 28(5):e75-e76. PubMed ID: 30676408
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Novel membrane-tube type glaucoma shunt device for glaucoma surgery.
    Ahn BH; Hwang YH; Han JC
    Clin Exp Ophthalmol; 2016 Dec; 44(9):776-782. PubMed ID: 27144958
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Aqueous misdirection after glaucoma drainage device implantation.
    Greenfield DS; Tello C; Budenz DL; Liebmann JM; Ritch R
    Ophthalmology; 1999 May; 106(5):1035-40. PubMed ID: 10328410
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ahmed valve, suture-less implantation: A new approach to an easier technique.
    García-Delpech S; Sanz-Marco E; Martinez-Castillo S; López-Prats MJ; Udaondo P; Salom D; Díaz-Llopis M
    J Glaucoma; 2013 Dec; 22(9):750-6. PubMed ID: 24304908
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Postoperative Complications in the Ahmed Baerveldt Comparison Study During Five Years of Follow-up.
    Budenz DL; Feuer WJ; Barton K; Schiffman J; Costa VP; Godfrey DG; Buys YM;
    Am J Ophthalmol; 2016 Mar; 163():75-82.e3. PubMed ID: 26596400
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Intracorneal Hematoma After Ahmed Glaucoma Valve Implant Surgery.
    Al Habash A; Al Abdulsalam O; Al-Qarni A
    J Glaucoma; 2017 Sep; 26(9):e202-e204. PubMed ID: 28557826
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Scleral fistula closure at the time of glaucoma drainage device tube repositioning: a novel technique.
    Panarelli JF; Banitt MR; Sidoti PA
    Arch Ophthalmol; 2012 Nov; 130(11):1447-51. PubMed ID: 23143444
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Aqueous Drainage Device Erosion: A Review of Rates, Risks, Prevention, and Repair.
    Bains U; Hoguet A
    Semin Ophthalmol; 2018; 33(1):1-10. PubMed ID: 29211548
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Consultation Section: Glaucoma. January consultation #2.
    Radcliffe N
    J Cataract Refract Surg; 2019 Jan; 45(1):105-106. PubMed ID: 30579515
    [No Abstract]   [Full Text] [Related]  

  • 19. Spontaneous extrusion of a stainless steel glaucoma drainage implant (Ex-PRESS).
    Tavolato M; Babighian S; Galan A
    Eur J Ophthalmol; 2006; 16(5):753-5. PubMed ID: 17061230
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Scanning Electron Microscopy Evaluation of an EX-PRESS Mini Glaucoma Shunt After Explantation.
    Tognetto D; Cecchini P; D'Aloisio R; Vattovani O; Turco G
    J Glaucoma; 2017 Jan; 26(1):e1-e4. PubMed ID: 27552510
    [TBL] [Abstract][Full Text] [Related]  