BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 28032297)

  • 21. Influences of 3D PET scanner components on increased scatter evaluated by a Monte Carlo simulation.
    Hirano Y; Koshino K; Iida H
    Phys Med Biol; 2017 May; 62(10):4017-4030. PubMed ID: 28287079
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A gate evaluation of the sources of error in quantitative
    Strydhorst J; Carlier T; Dieudonné A; Conti M; Buvat I
    Med Phys; 2016 Oct; 43(10):5320-5329. PubMed ID: 28105711
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Publicly available framework for simulating and experimentally validating clinical PET systems.
    O'Briain TB; Uribe C; Sechopoulos I; Michel C; Bazalova-Carter M
    Med Phys; 2023 Mar; 50(3):1549-1559. PubMed ID: 36215081
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Scatter and crosstalk corrections for (99m)Tc/(123)I dual-radionuclide imaging using a CZT SPECT system with pinhole collimators.
    Fan P; Hutton BF; Holstensson M; Ljungberg M; Pretorius PH; Prasad R; Ma T; Liu Y; Wang S; Thorn SL; Stacy MR; Sinusas AJ; Liu C
    Med Phys; 2015 Dec; 42(12):6895-911. PubMed ID: 26632046
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Spatial frequency spectrum of the x-ray scatter distribution in CBCT projections.
    Bootsma GJ; Verhaegen F; Jaffray DA
    Med Phys; 2013 Nov; 40(11):111901. PubMed ID: 24320434
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Characterization of scattered radiation in kV CBCT images using Monte Carlo simulations.
    Jarry G; Graham SA; Moseley DJ; Jaffray DJ; Siewerdsen JH; Verhaegen F
    Med Phys; 2006 Nov; 33(11):4320-9. PubMed ID: 17153411
    [TBL] [Abstract][Full Text] [Related]  

  • 27. On the use of Monte Carlo-derived dosimetric data in the estimation of patient dose from CT examinations.
    Perisinakis K; Tzedakis A; Damilakis J
    Med Phys; 2008 May; 35(5):2018-28. PubMed ID: 18561678
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Comparison of image quality between step-and-shoot and continuous bed motion techniques in whole-body
    Yamashita S; Yamamoto H; Nakaichi T; Yoneyama T; Yokoyama K
    Ann Nucl Med; 2017 Nov; 31(9):686-695. PubMed ID: 28815414
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Performance evaluation of the 32-module quadHIDAC small-animal PET scanner.
    Schäfers KP; Reader AJ; Kriens M; Knoess C; Schober O; Schäfers M
    J Nucl Med; 2005 Jun; 46(6):996-1004. PubMed ID: 15937311
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Evaluation of a scatter correction technique for single photon transmission measurements in PET by means of Monte Carlo simulations].
    Wegmann K; Brix G
    Nuklearmedizin; 2000; 39(3):67-71. PubMed ID: 10834193
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Full modelling of the MOSAIC animal PET system based on the GATE Monte Carlo simulation code.
    Merheb C; Petegnief Y; Talbot JN
    Phys Med Biol; 2007 Feb; 52(3):563-76. PubMed ID: 17228105
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Analytically based photon scatter modeling for a multipinhole cardiac SPECT camera.
    Pourmoghaddas A; Wells RG
    Med Phys; 2016 Nov; 43(11):6098. PubMed ID: 27806581
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Patient-specific scatter correction in clinical cone beam computed tomography imaging made possible by the combination of Monte Carlo simulations and a ray tracing algorithm.
    Thing RS; Bernchou U; Mainegra-Hing E; Brink C
    Acta Oncol; 2013 Oct; 52(7):1477-83. PubMed ID: 23879648
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Implementation and application of a Monte Carlo model for an in vivo micro computed tomography system.
    Manser P; Peter S; Volken W; Zulliger MA; Laib A; Koller B; Fix MK
    Phys Med; 2017 Dec; 44():34-41. PubMed ID: 29254589
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Attenuation-based estimation of patient size for the purpose of size specific dose estimation in CT. Part I. Development and validation of methods using the CT image.
    Wang J; Duan X; Christner JA; Leng S; Yu L; McCollough CH
    Med Phys; 2012 Nov; 39(11):6764-71. PubMed ID: 23127070
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A validated Geant4 model of a whole-body PET scanner with four-layer DOI detectors.
    Ahmed AM; Chacon A; Rutherford H; Akamatsu G; Mohammadi A; Nishikido F; Tashima H; Yoshida E; Yamaya T; Franklin DR; Rosenfeld A; Guatelli S; Safavi-Naeini M
    Phys Med Biol; 2020 Dec; 65(23):235051. PubMed ID: 33336650
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Evaluation of 3D Monte Carlo-based scatter correction for 99mTc cardiac perfusion SPECT.
    Xiao J; de Wit TC; Staelens SG; Beekman FJ
    J Nucl Med; 2006 Oct; 47(10):1662-9. PubMed ID: 17015903
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Monte Carlo simulation of a GE eXplore VISTA system for quantitative small animal PET imaging.
    Yang CC; Yu J; Lee JJ; Tsui BM
    Nucl Med Commun; 2010 Jan; 31(1):32-8. PubMed ID: 19972634
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Quantification with a dedicated breast PET/CT scanner.
    Bowen SL; Ferrero A; Badawi RD
    Med Phys; 2012 May; 39(5):2694-707. PubMed ID: 22559640
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Intensity distribution and impact of scatter for dual-source CT.
    Kyriakou Y; Kalender WA
    Phys Med Biol; 2007 Dec; 52(23):6969-89. PubMed ID: 18029988
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.