147 related articles for article (PubMed ID: 28038405)
1. Comprehensive mechanical characterization of PLA fabric combined with PCL to form a composite structure vascular graft.
Li C; Wang F; Douglas G; Zhang Z; Guidoin R; Wang L
J Mech Behav Biomed Mater; 2017 May; 69():39-49. PubMed ID: 28038405
[TBL] [Abstract][Full Text] [Related]
2. Preventing collapsing of vascular scaffolds: The mechanical behavior of PLA/PCL composite structure prostheses during in vitro degradation.
Li C; Wang F; Chen P; Zhang Z; Guidoin R; Wang L
J Mech Behav Biomed Mater; 2017 Nov; 75():455-462. PubMed ID: 28823899
[TBL] [Abstract][Full Text] [Related]
3. Degradable/non-degradable polymer composites for in-situ tissue engineering small diameter vascular prosthesis application.
Wang F; Mohammed A; Li C; Ge P; Wang L; King MW
Biomed Mater Eng; 2014; 24(6):2127-33. PubMed ID: 25226910
[TBL] [Abstract][Full Text] [Related]
4. Mechanical properties of small-diameter polyurethane vascular grafts reinforced by weft-knitted tubular fabric.
Xu W; Zhou F; Ouyang C; Ye W; Yao M; Xu B
J Biomed Mater Res A; 2010 Jan; 92(1):1-8. PubMed ID: 19165779
[TBL] [Abstract][Full Text] [Related]
5. Experimental noninferiority trial of synthetic small-caliber biodegradable versus stable vascular grafts.
Mugnai D; Tille JC; Mrówczyński W; de Valence S; Montet X; Möller M; Walpoth BH
J Thorac Cardiovasc Surg; 2013 Aug; 146(2):400-7.e1. PubMed ID: 23098749
[TBL] [Abstract][Full Text] [Related]
6. In vitro approach to the dilative behavior of knitted vascular prosthetic grafts.
Chakfe N; Dieval F; Wang L; Thaveau F; Rinckenbach S; Edah-Tally S; Mathieu D; Le Magnen JF; Riepe G; Kretz JG; Durand B;
Ann Vasc Surg; 2008; 22(3):402-11. PubMed ID: 18466818
[TBL] [Abstract][Full Text] [Related]
7. The mechanical performance of weft-knitted/electrospun bilayer small diameter vascular prostheses.
Xie Y; Guan Y; Kim SH; King MW
J Mech Behav Biomed Mater; 2016 Aug; 61():410-418. PubMed ID: 27111627
[TBL] [Abstract][Full Text] [Related]
8. Towards compliant small-diameter vascular grafts: Predictive analytical model and experiments.
Bouchet M; Gauthier M; Maire M; Ajji A; Lerouge S
Mater Sci Eng C Mater Biol Appl; 2019 Jul; 100():715-723. PubMed ID: 30948109
[TBL] [Abstract][Full Text] [Related]
9. Thin-film nitinol (NiTi): a feasibility study for a novel aortic stent graft material.
Rigberg D; Tulloch A; Chun Y; Mohanchandra KP; Carman G; Lawrence P
J Vasc Surg; 2009 Aug; 50(2):375-80. PubMed ID: 19631872
[TBL] [Abstract][Full Text] [Related]
10. Porcine carotid artery replacement with biodegradable electrospun poly-e-caprolactone vascular prosthesis.
Mrówczyński W; Mugnai D; de Valence S; Tille JC; Khabiri E; Cikirikcioglu M; Möller M; Walpoth BH
J Vasc Surg; 2014 Jan; 59(1):210-9. PubMed ID: 23707057
[TBL] [Abstract][Full Text] [Related]
11. Relation between tensile tests and compliance in polyester textile vascular prostheses.
Lucereau B; Koffhi F; Heim F; Lejay A; Thaveau F; Geny B; Durand B; Georg Y; Chakfé N
Ann Vasc Surg; 2015 Aug; 29(6):1300-6. PubMed ID: 26004959
[TBL] [Abstract][Full Text] [Related]
12. Influence of weft-knitted tubular fabric on radial mechanical property of coaxial three-layer small-diameter vascular graft.
Yang H; Zhu G; Zhang Z; Wang Z; Fang J; Xu W
J Biomed Mater Res B Appl Biomater; 2012 Feb; 100(2):342-9. PubMed ID: 22113920
[TBL] [Abstract][Full Text] [Related]
13. Randomized controlled trial comparing the safety and efficacy between the FUSION BIOLINE heparin-coated vascular graft and the standard expanded polytetrafluoroethylene graft for femoropopliteal bypass.
Lumsden AB; Morrissey NJ;
J Vasc Surg; 2015 Mar; 61(3):703-12.e1. PubMed ID: 25720929
[TBL] [Abstract][Full Text] [Related]
14. A compliant Corethane/Dacron composite vascular prosthesis. Comparison with 4-mm ePTFE grafts in a canine model.
Wilson GJ; MacGregor DC; Klement P; Weber BA; Binnington AG; Pinchuk L
ASAIO J; 1993; 39(3):M526-31. PubMed ID: 8268591
[TBL] [Abstract][Full Text] [Related]
15. A Corethane/polyester composite vascular prosthesis for vascular access. Comparison with expanded polytetrafluoroethylene grafts in a canine model.
Wilson GJ; MacGregor DC; Bridgeman J; Weber BA; Binnington AG; Pinchuk L
ASAIO J; 1995; 41(3):M728-34. PubMed ID: 8573903
[TBL] [Abstract][Full Text] [Related]
16. In situ evolution of the mechanical properties of stretchable and non-stretchable ePTFE vascular grafts and adjacent native vessels.
Famaey N; Verhoeven J; Jacobs S; Pettinari M; Meyns B
Int J Artif Organs; 2014 Dec; 37(12):900-10. PubMed ID: 25450323
[TBL] [Abstract][Full Text] [Related]
17. Mechanical and microstructural analysis of a radially expandable vascular conduit for neonatal and pediatric cardiovascular surgery.
Loneker AE; Luketich SK; Bernstein D; Kalra A; Nugent AW; D'Amore A; Faulk DM
J Biomed Mater Res B Appl Biomater; 2018 Feb; 106(2):659-671. PubMed ID: 28296198
[TBL] [Abstract][Full Text] [Related]
18. Effects of yarn types and fabric types on the compliance and bursting strength of vascular grafts.
Lou CW; Lu PC; Hu JJ; Lin JH
J Mech Behav Biomed Mater; 2016 Jun; 59():474-483. PubMed ID: 26995157
[TBL] [Abstract][Full Text] [Related]
19. Degradation and healing characteristics of small-diameter poly(epsilon-caprolactone) vascular grafts in the rat systemic arterial circulation.
Pektok E; Nottelet B; Tille JC; Gurny R; Kalangos A; Moeller M; Walpoth BH
Circulation; 2008 Dec; 118(24):2563-70. PubMed ID: 19029464
[TBL] [Abstract][Full Text] [Related]
20. Endothelialization of electrospun polycaprolactone (PCL) small caliber vascular grafts spun from different polymer blends.
Pfeiffer D; Stefanitsch C; Wankhammer K; Müller M; Dreyer L; Krolitzki B; Zernetsch H; Glasmacher B; Lindner C; Lass A; Schwarz M; Muckenauer W; Lang I
J Biomed Mater Res A; 2014 Dec; 102(12):4500-9. PubMed ID: 24532056
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]