These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

219 related articles for article (PubMed ID: 28041613)

  • 1. Removal of a broken trigen intertan intertrochanteric antegrade nail.
    Zheng XL; Park YC; Kim S; An H; Yang KH
    Injury; 2017 Feb; 48(2):557-559. PubMed ID: 28041613
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Technique for Removal of Broken InterTAN Integrated Cephalomedullary Screw.
    Burgesson BN; Coles CP
    J Orthop Trauma; 2021 Sep; 35(9):e352-e354. PubMed ID: 33278207
    [TBL] [Abstract][Full Text] [Related]  

  • 3. TRIGEN INTERTAN intramedullary nail versus sliding hip screw: a prospective, randomized multicenter study on pain, function, and complications in 684 patients with an intertrochanteric or subtrochanteric fracture and one year of follow-up.
    Matre K; Vinje T; Havelin LI; Gjertsen JE; Furnes O; Espehaug B; Kjellevold SH; Fevang JM
    J Bone Joint Surg Am; 2013 Feb; 95(3):200-8. PubMed ID: 23389782
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Breakage of a Lag Screw of Cephalomedullary Nail: A Technique of Removal.
    Tantigate D; Riansuwan K; Mahaisavariya B; Sukjaitham K
    Clin Orthop Surg; 2015 Jun; 7(2):261-3. PubMed ID: 26217475
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Sigmoid perforation after medial migration of lag screw in gamma nailing.
    Tauber M; Resch H
    Arch Orthop Trauma Surg; 2006 Mar; 126(2):118-22. PubMed ID: 16402202
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Malpositioning of the lag screws by 1- or 2-screw nailing systems for pertrochanteric femoral fractures: a biomechanical comparison of gamma 3 and intertan.
    Nüchtern JV; Ruecker AH; Sellenschloh K; Rupprecht M; Püschel K; Rueger JM; Morlock MM; Lehmann W
    J Orthop Trauma; 2014 May; 28(5):276-82. PubMed ID: 24751606
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of a twin interlocking derotation and compression screw cephalomedullary nail (InterTAN) with a single screw derotation cephalomedullary nail (proximal femoral nail antirotation): a systematic review and meta-analysis for intertrochanteric fractures.
    Nherera L; Trueman P; Horner A; Watson T; Johnstone AJ
    J Orthop Surg Res; 2018 Mar; 13(1):46. PubMed ID: 29499715
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impact of tip-apex distance and femoral head lag screw position on treatment outcomes of unstable intertrochanteric fractures using cephalomedullary nails.
    Lee CH; Su KC; Chen KH; Pan CC; Wu YC
    J Int Med Res; 2018 Jun; 46(6):2128-2140. PubMed ID: 29848122
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Medial migration of lag screw after gamma nailing.
    Thein E; De Cannière A; Burn A; Borens O
    Injury; 2014 Aug; 45(8):1275-9. PubMed ID: 24933440
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Embedding the lateral end of the lag screw within the lateral wall in the repair of reverse obliquity intertrochanteric femur fracture.
    Hiragami K; Ishii J
    J Int Med Res; 2018 Mar; 46(3):1103-1108. PubMed ID: 29082791
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cervicocephalic medial screw migration after intertrochanteric fracture fixation, OTA/AO 31-A2, using intramedullary nail Gamma3: report of 2 cases and literature review.
    Lozano-Alvarez C; Alier A; Pelfort X; Martínez-Díaz S; Puig L
    J Orthop Trauma; 2013 Nov; 27(11):e264-7. PubMed ID: 23515128
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Removal of a broken nail using a guide wire and a screw.
    Karladani AH
    Acta Orthop; 2006 Dec; 77(6):986-8. PubMed ID: 17260212
    [No Abstract]   [Full Text] [Related]  

  • 13. Proximal Femoral Nail Unlocked versus Locked (ProFNUL): a protocol for a multicentre, parallel-armed randomised controlled trial for the effect of femoral nail mode of lag screw locking and screw configuration in the treatment of intertrochanteric femur fractures.
    Sivakumar A; Thewlis D; Ladurner A; Edwards S; Rickman M
    BMJ Open; 2020 Feb; 10(2):e032640. PubMed ID: 32047013
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Removal of broken long gamma nail: a modified guide wires technique.
    Riansuwan K; Carter C; Nercessian O
    J Trauma; 2008 Feb; 64(2):517-9. PubMed ID: 18301225
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical evaluation of interlocking lag screw design in intramedullary nailing of unstable pertrochanteric fractures.
    Hoffmann S; Paetzold R; Stephan D; Püschel K; Buehren V; Augat P
    J Orthop Trauma; 2013 Sep; 27(9):483-90. PubMed ID: 23860133
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The trochanteric nail versus the sliding hip screw for intertrochanteric hip fractures: a review of 93 cases.
    Crawford CH; Malkani AL; Cordray S; Roberts CS; Sligar W
    J Trauma; 2006 Feb; 60(2):325-8; discussion 328-9. PubMed ID: 16508490
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A newly designed locked intramedullary nail for trochanteric hip fractures fixation: results of the first 100 Trochanteric implantations.
    Loubignac F; Chabas JF
    Orthop Traumatol Surg Res; 2009 Apr; 95(2):139-44. PubMed ID: 19345659
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cephalomedullary Nail Fixation of Intertrochanteric Femur Fractures: Are Two Proximal Screws Better Than One?
    Serrano R; Blair JA; Watson DT; Infante AF; Shah AR; Mir HR; Maxson BJ; Downes KL; Sanders RW
    J Orthop Trauma; 2017 Nov; 31(11):577-582. PubMed ID: 28827501
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The treatment of reverse obliquity intertrochanteric fractures with the intramedullary hip nail.
    Park SY; Yang KH; Yoo JH; Yoon HK; Park HW
    J Trauma; 2008 Oct; 65(4):852-7. PubMed ID: 18849802
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Does modern nail geometry affect positioning in the distal femur of elderly patients with hip fractures? A comparison of otherwise identical intramedullary nails with a 200 versus 150 cm radius of curvature.
    Collinge CA; Beltran CP
    J Orthop Trauma; 2013 Jun; 27(6):299-302. PubMed ID: 23287751
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.