BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 28044985)

  • 1. Radiation dose absorbed by operators during transradial percutaneous coronary procedures comparing different protective drapes: the RADIATION study.
    Sciahbasi A; Rigattieri S; Sarandrea A; Cera M; Di Russo C; Fedele S; Romano S; Pugliese FR; Penco M
    EuroIntervention; 2017 Apr; 12(18):e2253-e2261. PubMed ID: 28044985
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Extended Protective Shield Under Table to Reduce Operator Radiation Dose in Percutaneous Coronary Procedures.
    Sciahbasi A; Sarandrea A; Rigattieri S; Patrizi R; Cera M; Di Russo C; Zezza L; Fedele S; Ferraiuolo G
    Circ Cardiovasc Interv; 2019 Feb; 12(2):e007586. PubMed ID: 30732471
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Efficacy of MAVIG X-Ray Protective Drapes in Reducing Operator Radiation Dose in the Cardiac Catheterization Laboratory: A Randomized Controlled Trial.
    McCutcheon K; Vanhaverbeke M; Pauwels R; Dabin J; Schoonjans W; Bennett J; Adriaenssens T; Dubois C; Sinnaeve P; Desmet W
    Circ Cardiovasc Interv; 2020 Nov; 13(11):e009627. PubMed ID: 33092401
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Staff radiation dose during percutaneous coronary procedures: Role of adjunctive protective drapes.
    Sciahbasi A; Sarandrea A; Rigattieri S; Patrizi R; Cera M; Di Russo C; Perone F; Porretta V; Fedele S; Romano S; Penco M; Ferraiuolo G
    Cardiovasc Revasc Med; 2018 Oct; 19(7 Pt A):755-758. PubMed ID: 29691182
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Determinants of operator radiation exposure during percutaneous coronary procedures.
    Sciahbasi A; Rigattieri S; Sarandrea A; Cera M; Di Russo C; Fedele S; Patrizi R; Romano S; Pugliese FR; Penco M; Pancholy SB
    Am Heart J; 2017 May; 187():10-18. PubMed ID: 28454793
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Randomized comparison of operator radiation exposure comparing transradial and transfemoral approach for percutaneous coronary procedures: rationale and design of the minimizing adverse haemorrhagic events by TRansradial access site and systemic implementation of angioX - RAdiation Dose study (RAD-MATRIX).
    Sciahbasi A; Calabrò P; Sarandrea A; Rigattieri S; Tomassini F; Sardella G; Zavalloni D; Cortese B; Limbruno U; Tebaldi M; Gagnor A; Rubartelli P; Zingarelli A; Valgimigli M
    Cardiovasc Revasc Med; 2014 Jun; 15(4):209-13. PubMed ID: 24746599
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reduction in operator radiation exposure during transradial catheterization and intervention using a simple lead drape.
    Iqtidar AF; Jeon C; Rothman R; Snead R; Pyne CT
    Am Heart J; 2013 Mar; 165(3):293-8. PubMed ID: 23453095
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Operator radiation exposure during percutaneous coronary procedures through the left or right radial approach: the TALENT dosimetric substudy.
    Sciahbasi A; Romagnoli E; Trani C; Burzotta F; Sarandrea A; Summaria F; Patrizi R; Rao S; Lioy E
    Circ Cardiovasc Interv; 2011 Jun; 4(3):226-31. PubMed ID: 21586692
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Assessment of clinical occupational dose reduction effect of a new interventional cardiology shield for radial access combined with a scatter reducing drape.
    Gilligan P; Lynch J; Eder H; Maguire S; Fox E; Doyle B; Casserly I; McCann H; Foley D
    Catheter Cardiovasc Interv; 2015 Nov; 86(5):935-40. PubMed ID: 26154301
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Decreasing operators' radiation exposure during coronary procedures: the transradial radiation protection board.
    Behan M; Haworth P; Colley P; Brittain M; Hince A; Clarke M; Ghuran A; Saha M; Hildick-Smith D
    Catheter Cardiovasc Interv; 2010 Jul; 76(1):79-84. PubMed ID: 20578091
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Operator radiation exposure during right or left transradial coronary angiography: A phantom study.
    Sciahbasi A; Rigattieri S; Sarandrea A; Cera M; Di Russo C; Fedele S; Romano S; Pugliese FR; Penco M
    Cardiovasc Revasc Med; 2015; 16(7):386-90. PubMed ID: 26235976
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Determinants of radiation dose during right transradial access: Insights from the RAD-MATRIX study.
    Sciahbasi A; Frigoli E; Sarandrea A; Calabrò P; Rubartelli P; Cortese B; Tomassini F; Zavalloni D; Tebaldi M; Calabria P; Rigattieri S; Zingarelli A; Sardella G; Lupi A; Rothenbühler M; Heg D; Valgimigli M
    Am Heart J; 2018 Feb; 196():113-118. PubMed ID: 29421003
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Efficacy of the RADPAD Protection Drape in Reducing Operators' Radiation Exposure in the Catheterization Laboratory: A Sham-Controlled Randomized Trial.
    Vlastra W; Delewi R; Sjauw KD; Beijk MA; Claessen BE; Streekstra GJ; Bekker RJ; van Hattum JC; Wykrzykowska JJ; Vis MM; Koch KT; de Winter RJ; Piek JJ; Henriques JPS
    Circ Cardiovasc Interv; 2017 Nov; 10(11):. PubMed ID: 29089313
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Randomized Controlled Trial of Radiation Protection With a Patient Lead Shield and a Novel, Nonlead Surgical Cap for Operators Performing Coronary Angiography or Intervention.
    Alazzoni A; Gordon CL; Syed J; Natarajan MK; Rokoss M; Schwalm JD; Mehta SR; Sheth T; Valettas N; Velianou J; Pandie S; Al Khdair D; Tsang M; Meeks B; Colbran K; Waller E; Fu Lee S; Marsden T; Jolly SS
    Circ Cardiovasc Interv; 2015 Aug; 8(8):e002384. PubMed ID: 26253734
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Operator exposure to x-ray in left and right radial access during percutaneous coronary procedures: OPERA randomised study.
    Dominici M; Diletti R; Milici C; Bock C; Placanica A; D'Alessandro G; Arrivi A; Italiani M; Buono E; Boschetti E
    Heart; 2013 Apr; 99(7):480-4. PubMed ID: 23343690
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effectiveness of low rate fluoroscopy at reducing operator and patient radiation dose during transradial coronary angiography and interventions.
    Abdelaal E; Plourde G; MacHaalany J; Arsenault J; Rimac G; Déry JP; Barbeau G; Larose E; De Larochellière R; Nguyen CM; Allende R; Ribeiro H; Costerousse O; Mongrain R; Bertrand OF;
    JACC Cardiovasc Interv; 2014 May; 7(5):567-74. PubMed ID: 24746649
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A randomized comparison of the transradial and transfemoral approaches for coronary artery bypass graft angiography and intervention: the RADIAL-CABG Trial (RADIAL Versus Femoral Access for Coronary Artery Bypass Graft Angiography and Intervention).
    Michael TT; Alomar M; Papayannis A; Mogabgab O; Patel VG; Rangan BV; Luna M; Hastings JL; Grodin J; Abdullah S; Banerjee S; Brilakis ES
    JACC Cardiovasc Interv; 2013 Nov; 6(11):1138-44. PubMed ID: 24139930
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A randomized controlled trial to assess operator radiation exposure from cardiac catheterization procedures using RAD BOARD® with standard pelvic shielding versus standard pelvic shielding alone.
    Suryadevara R; Brown ED; Green SM; Scott TD; Nordberg CM; Blankenship JC
    Catheter Cardiovasc Interv; 2020 Jan; 95(1):83-88. PubMed ID: 30866175
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Vascular access and radiation exposure during percutaneous coronary procedures.
    Sciahbasi A; Babbaro M; Confessore P; Cera M; Di Russo C; Patrizi R; Fedele S
    Minerva Cardioangiol; 2020 Dec; 68(6):592-598. PubMed ID: 32326678
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A randomized study comparing the use of a pelvic lead shield during trans-radial interventions: Threefold decrease in radiation to the operator but double exposure to the patient.
    Musallam A; Volis I; Dadaev S; Abergel E; Soni A; Yalonetsky S; Kerner A; Roguin A
    Catheter Cardiovasc Interv; 2015 Jun; 85(7):1164-70. PubMed ID: 25510441
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.