These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 28053427)

  • 1. Atlas of the Spectrum of a Platinum/Neon Hollow-Cathode Reference Lamp in the Region 1130-4330 Å.
    Sansonetti JE; Reader J; Sansonetti CJ; Acquista N
    J Res Natl Inst Stand Technol; 1992; 97(1):1-7. PubMed ID: 28053427
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The Iron-Neon Hollow-Cathode Spectrum.
    Crosswhite HM
    J Res Natl Bur Stand A Phys Chem; 1975; 79A(1):17-69. PubMed ID: 32184499
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Precision measurement of wavelengths emitted by a molecular fluorine laser at 157 nm.
    Sansonetti CJ; Reader J; Vogler K
    Appl Opt; 2001 Apr; 40(12):1974-8. PubMed ID: 18357199
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Characterization of a Pt-Ne hollow cathode spectral line source.
    Klose JZ; Hartig GF; Rosenberg WJ
    Appl Opt; 1990 Jul; 29(19):2951-9. PubMed ID: 20567356
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Reference wavelengths of Si ii, C ii, Fe i, and Ni ii for quasar absorption spectroscopy.
    Nave G; Clear C
    Mon Not R Astron Soc; 2021 Apr; 502(4):. PubMed ID: 34815587
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Ultraviolet optogalvanic laser spectroscopy of iron for reference wavelengths.
    Babin F; Camus P; Gagné JM; Pillet P; Boulmer J
    Opt Lett; 1987 Jul; 12(7):468-70. PubMed ID: 19741767
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Use of the optogalvanic effect and the uranium atlas for wavelength calibration of pulsed lasers.
    Dovichi NJ; Moore DS; Keller RA
    Appl Opt; 1982 Apr; 21(8):1468-73. PubMed ID: 20389875
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Studies on pulsed optogalvanic effect in Eu/Ne hollow cathode discharge.
    Saini VK; Kumar P; Dixit SK; Nakhe SV
    Appl Opt; 2014 Jul; 53(19):4320-6. PubMed ID: 25089996
    [TBL] [Abstract][Full Text] [Related]  

  • 9. High-Resolution Observations of the Infrared Spectrum of Neutral Neon.
    Sansonetti CJ; Blackwell MM; Saloman EB
    J Res Natl Inst Stand Technol; 2004; 109(3):371-89. PubMed ID: 27366619
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Measuring method of spatial and spectral distribution of hollow cathode lamp].
    Wu ZZ; Du XW; Li CY; Ke GY; Wang QP
    Guang Pu Xue Yu Guang Pu Fen Xi; 2011 Oct; 31(10):2647-50. PubMed ID: 22250526
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development of a see-through hollow cathode discharge lamp for (Li/Ne) optogalvanic studies.
    Saini VK; Kumar P; Sarangpani KK; Dixit SK; Nakhe SV
    Rev Sci Instrum; 2017 Sep; 88(9):093101. PubMed ID: 28964210
    [TBL] [Abstract][Full Text] [Related]  

  • 12. New Vacuum Ultraviolet Wavelengths and Revised Energy Levels in the Second Spectrum of Zinc (Zn ii).
    Martin WC; Kaufman V
    J Res Natl Bur Stand A Phys Chem; 1970; 74A(1):11-22. PubMed ID: 32523166
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Spectral calibration of the atmosphere ultraviolet imaging spectrograph using a PtNe lamp].
    Li C; Wang YM
    Guang Pu Xue Yu Guang Pu Fen Xi; 2010 Dec; 30(12):3302-5. PubMed ID: 21322227
    [TBL] [Abstract][Full Text] [Related]  

  • 14. High current hollow cathode as a radiometric transfer standard source for the extreme vacuum ultraviolet.
    Danzmann K; Günther M; Fischer J; Kock M; Kühne M
    Appl Opt; 1988 Dec; 27(23):4947-51. PubMed ID: 20539679
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High-current hollow-cathode source as a radiant intensity standard in the 40-125-nm wavelength range.
    Hollandt J; Kuhne M; Wende B
    Appl Opt; 1994 Jan; 33(1):68-74. PubMed ID: 20861990
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The Spectrum of Doubly Ionized Tungsten (W III).
    Iglesias L; Cabeza MI; Rico FR; Garcia-Riquelme O; Kaufman V
    J Res Natl Inst Stand Technol; 1989; 94(4):221-258. PubMed ID: 28053412
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Argon I Lines Produced in a Hollow Cathode Source, 332 nm to 5865 nm.
    Whaling W; Anderson WH; Carle MT; Brault JW; Zarem HA
    J Res Natl Inst Stand Technol; 2002; 107(2):149-69. PubMed ID: 27446724
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Analysis of the Spectrum of Doubly Ionized Molybdenum (Mo III).
    Iglesias L; Cabeza MI; Kaufman V
    J Res Natl Inst Stand Technol; 1990; 95(6):647-688. PubMed ID: 28179799
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improved Wavelength Calibration by Modeling the Spectrometer.
    Liu D; Hennelly BM
    Appl Spectrosc; 2022 Nov; 76(11):1283-1299. PubMed ID: 35726593
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Photoelectric scanning (6.65-m) spectrometer for VUV cross-section measurements.
    Yoshino K; Freeman DE; Parkinson WH
    Appl Opt; 1980 Jan; 19(1):66-71. PubMed ID: 20216795
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.