These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

235 related articles for article (PubMed ID: 28057222)

  • 1. Leaflet Thrombosis in Surgically Explanted or Post-Mortem TAVR Valves.
    Mangione FM; Jatene T; Gonçalves A; Fishbein GA; Mitchell RN; Pelletier MP; Kaneko T; Shah PB; Nyman CB; Shook D; Blankstein R; Padera RF; Bhatt DL
    JACC Cardiovasc Imaging; 2017 Jan; 10(1):82-85. PubMed ID: 28057222
    [No Abstract]   [Full Text] [Related]  

  • 2. Color Paucity as a Marker of Transcatheter Valve Thrombosis.
    Marcoff L; Koulogiannis KP; Aldaia L; Fuschetto DP; Kipperman RM; Laighold S; Gillam LD
    JACC Cardiovasc Imaging; 2017 Jan; 10(1):78-81. PubMed ID: 28057221
    [No Abstract]   [Full Text] [Related]  

  • 3. Bioprosthesis leaflet thrombosis following self-expanding valve-in-valve transcatheter aortic valve replacement in patient taking factor Xa inhibitor and warfarin: A case report.
    Buchanan KD; Alraies MC; Weissman G; Ben-Dor I; Satler LF; Waksman R
    Cardiovasc Revasc Med; 2018 Jan; 19(1 Pt A):29-32. PubMed ID: 29066342
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pathology of self-expanding transcatheter aortic valves: Findings from the CoreValve US pivotal trials.
    Yahagi K; Torii S; Ladich E; Kutys R; Romero ME; Mori H; Kolodgie FD; Popma JJ; Virmani R; Finn AV
    Catheter Cardiovasc Interv; 2018 Apr; 91(5):947-955. PubMed ID: 28895294
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transcatheter Aortic Heart Valves: Histological Analysis Providing Insight to Leaflet Thickening and Structural Valve Degeneration.
    Sellers SL; Turner CT; Sathananthan J; Cartlidge TRG; Sin F; Bouchareb R; Mooney J; Nørgaard BL; Bax JJ; Bernatchez PN; Dweck MR; Granville DJ; Newby DE; Lauck S; Webb JG; Payne GW; Pibarot P; Blanke P; Seidman MA; Leipsic JA
    JACC Cardiovasc Imaging; 2019 Jan; 12(1):135-145. PubMed ID: 30448122
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Subclinical leaflet thrombosis in surgical and transcatheter bioprosthetic aortic valves: an observational study.
    Chakravarty T; Søndergaard L; Friedman J; De Backer O; Berman D; Kofoed KF; Jilaihawi H; Shiota T; Abramowitz Y; Jørgensen TH; Rami T; Israr S; Fontana G; de Knegt M; Fuchs A; Lyden P; Trento A; Bhatt DL; Leon MB; Makkar RR; ;
    Lancet; 2017 Jun; 389(10087):2383-2392. PubMed ID: 28330690
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Clinical Bioprosthetic Heart Valve Thrombosis After Transcatheter Aortic Valve Replacement: Incidence, Characteristics, and Treatment Outcomes.
    Jose J; Sulimov DS; El-Mawardy M; Sato T; Allali A; Holy EW; Becker B; Landt M; Kebernik J; Schwarz B; Richardt G; Abdel-Wahab M
    JACC Cardiovasc Interv; 2017 Apr; 10(7):686-697. PubMed ID: 28385406
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Three mechanisms of early failure of transcatheter aortic valves: Valve thrombosis, cusp rupture, and accelerated calcification.
    Summers MR; Cremer PC; Jaber WA
    J Thorac Cardiovasc Surg; 2017 May; 153(5):e87-e93. PubMed ID: 28073568
    [No Abstract]   [Full Text] [Related]  

  • 9. TAVR-Related Complications: Why Did We Forget the Design of a Normal Aortic Valve?
    Sengupta PP; Narula J
    JACC Cardiovasc Imaging; 2017 Jan; 10(1):100-103. PubMed ID: 28057219
    [No Abstract]   [Full Text] [Related]  

  • 10. Stuck Leaflet After Transcatheter Aortic Valve Replacement With a SAPIEN-3 Valve: New Valve, Old Complication.
    Couture EL; Labbé BM; DeLarochellière R; Rodés-Cabau J; Paradis JM
    JACC Cardiovasc Interv; 2016 Jul; 9(14):e133-5. PubMed ID: 27372196
    [No Abstract]   [Full Text] [Related]  

  • 11. Basal leaflet thickening and color paucity in the echocardiographic evaluation of subclinical leaflet thrombosis after transcatheter aortic valve replacement.
    Hamadanchi A; Bäz L; Möbius-Winkler S; Teichgräber U; Schulze PC; Franz M
    Int J Cardiovasc Imaging; 2019 Jan; 35(1):119-120. PubMed ID: 30109453
    [No Abstract]   [Full Text] [Related]  

  • 12. Could anticoagulation avoid bioprosthesis subclinical thrombosis in patients undergoing transcatheter aortic valve replacement?
    Huchet F; Letocart V; Guerin P; Cueff C; Roy-Giocosa J; Guyomarch-Delasalle B; Jaafar P; Manigold T
    Arch Cardiovasc Dis; 2018 Jan; 111(1):25-32. PubMed ID: 28943264
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Acute Obstructive Thrombosis of Sapien 3 Valve After Valve-in-Valve Transcatheter Aortic Valve Replacement for Degenerated Mosaic 21 Valve.
    Gandolfo C; Turrisi M; Follis F; Clemenza F; Falletta C; Gentile G; Liotta R; Raffa GM; Pilato M
    JACC Cardiovasc Interv; 2018 Jan; 11(2):215-217. PubMed ID: 29055768
    [No Abstract]   [Full Text] [Related]  

  • 14. Systematic CT Methodology for the Evaluation of Subclinical Leaflet Thrombosis.
    Jilaihawi H; Asch FM; Manasse E; Ruiz CE; Jelnin V; Kashif M; Kawamori H; Maeno Y; Kazuno Y; Takahashi N; Olson R; Alkhatib J; Berman D; Friedman J; Gellada N; Chakravarty T; Makkar RR
    JACC Cardiovasc Imaging; 2017 Apr; 10(4):461-470. PubMed ID: 28385256
    [TBL] [Abstract][Full Text] [Related]  

  • 15. TAVR and Thrombosis.
    Trantalis G; Toutouzas K; Latsios G; Synetos A; Brili S; Logitsi D; Penesopoulou V; Tousoulis D
    JACC Cardiovasc Imaging; 2017 Jan; 10(1):86-87. PubMed ID: 28057223
    [No Abstract]   [Full Text] [Related]  

  • 16. Aortic Regurgitation after TAVR: From Bad to Worse.
    Hiltrop N; Adriaenssens T; Herijgers P; Dubois C
    J Heart Valve Dis; 2016 Mar; 25(2):182-184. PubMed ID: 27989062
    [TBL] [Abstract][Full Text] [Related]  

  • 17. SAPIEN S3 Leaflet Malfunction With Severe Intravalvular Aortic Insufficiency Immediately Post-Deployment.
    Singh GD; Southard JA; Smith TW; Boyd WD; Wong GB; Perry PA; Low RI
    JACC Cardiovasc Interv; 2017 Feb; 10(4):e31-e32. PubMed ID: 28231917
    [No Abstract]   [Full Text] [Related]  

  • 18. Deformation of Stabilization Arch Following Post-Dilatation of Symetis ACURATE Neo Aortic Bioprosthesis.
    Putrino AL; Roper D; Raffel CO; Walters DL
    JACC Cardiovasc Interv; 2018 Mar; 11(6):605-606. PubMed ID: 29501541
    [No Abstract]   [Full Text] [Related]  

  • 19. Early Postoperative Thrombosis of Transcatheter Aortic Valve-in-Valve Prosthesis.
    Francica A; Dodonov M; Tonelli F; Paolino G; Pesarini G; Ribichini F; Faggian G; Onorati F
    Ann Thorac Surg; 2021 Jul; 112(1):e21-e22. PubMed ID: 33412136
    [TBL] [Abstract][Full Text] [Related]  

  • 20. High-Risk Transcatheter Aortic Valve Replacement With Evolut-R CoreValve to Simultaneously Treat Severe Calcific Aortic Stenosis and a Large Aortic Root Pseudoaneurysm.
    Issa O; Posina K; Arenas I; Escolar E; La Pietra A; Beohar N
    JACC Cardiovasc Interv; 2016 Jul; 9(14):e141-3. PubMed ID: 27372192
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 12.