BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

1268 related articles for article (PubMed ID: 28062549)

  • 61. Transcatheter aortic valve implantation in degenerative sutureless perceval aortic bioprosthesis.
    Landes U; Sagie A; Kornowski R
    Catheter Cardiovasc Interv; 2018 Apr; 91(5):1000-1004. PubMed ID: 27696650
    [TBL] [Abstract][Full Text] [Related]  

  • 62. Transcatheter JenaValve Implantation in a Stentless Prosthesis: A Challenging Case After 4 Previous Aortic Procedures.
    Sponga S; Mazzaro E; Bagur R; Livi U
    Can J Cardiol; 2017 Apr; 33(4):555.e17-555.e19. PubMed ID: 28174055
    [TBL] [Abstract][Full Text] [Related]  

  • 63. Transcatheter aortic valve implantation with a Sapien 3 Commander 20 mm valves in patients with degenerated 19 mm bioprosthetic aortic valve.
    Loyalka P; Nascimbene A; Schechter M; Petrovic M; Sundara Raman A; Gregoric ID; Kar B
    Catheter Cardiovasc Interv; 2017 Jun; 89(7):1280-1285. PubMed ID: 27696659
    [TBL] [Abstract][Full Text] [Related]  

  • 64. Long-Term Outcome of the Sorin Freedom SOLO Stentless Aortic Valve.
    Christ T; Claus B; Zielinski C; Falk V; Grubitzsch H
    J Heart Valve Dis; 2016 Nov; 25(6):679-684. PubMed ID: 28290166
    [TBL] [Abstract][Full Text] [Related]  

  • 65. High Residual Gradient Following a Self-Expandable Transcatheter Aortic Valve-in-Valve Implantation - Risk Factor Analysis, Outcomes, and Survival.
    Stankowski T; Aboul-Hassan SS; Stepinski P; Gasior T; Salem M; Erkenov T; Herwig V; Harnath A; Muehle A; Sá MPBO; Fritzsche D; Perek B
    Braz J Cardiovasc Surg; 2022 Oct; 37(5):710-720. PubMed ID: 34673507
    [TBL] [Abstract][Full Text] [Related]  

  • 66. Isolated Redo Aortic Valve Replacement Versus Valve-in-Valve Transcatheter Valve Replacement.
    Patel PM; Chiou E; Cao Y; Binongo J; Guyton RA; Leshnower B; Grubb KJ; Chen EP
    Ann Thorac Surg; 2021 Aug; 112(2):539-545. PubMed ID: 33129775
    [TBL] [Abstract][Full Text] [Related]  

  • 67. Impact of patient-prosthesis mismatch after transcatheter aortic valve-in-valve implantation in degenerated bioprostheses.
    Seiffert M; Conradi L; Baldus S; Knap M; Schirmer J; Franzen O; Koschyk D; Meinertz T; Reichenspurner H; Treede H
    J Thorac Cardiovasc Surg; 2012 Mar; 143(3):617-24. PubMed ID: 22169448
    [TBL] [Abstract][Full Text] [Related]  

  • 68. Valve-in-valve-in-valve: Balloon expandable transcatheter heart valve in failing self-expandable transcatheter heart valve in deteriorated surgical bioprosthesis.
    Schaefer A; Deuschl F; Conradi L; Schäfer U
    Catheter Cardiovasc Interv; 2018 Dec; 92(7):E481-E485. PubMed ID: 30196560
    [TBL] [Abstract][Full Text] [Related]  

  • 69. Transcatheter valve-in-valve replacement of degenerated bioprosthetic aortic valves: a single Australian Centre experience.
    Subban V; Savage M; Crowhurst J; Poon K; Incani A; Aroney C; Tesar P; Clarke A; Raffel C; Murdoch D; Platts D; Burstow D; Saireddy R; Bett N; Walters DL
    Cardiovasc Revasc Med; 2014; 15(8):388-92. PubMed ID: 25456416
    [TBL] [Abstract][Full Text] [Related]  

  • 70. Valve-in-valve TAVI and risk of coronary obstruction: Validation of the VIVID classification.
    Tomii D; Okuno T; Lanz J; Stortecky S; Reineke D; Windecker S; Pilgrim T
    J Cardiovasc Comput Tomogr; 2023; 17(2):105-111. PubMed ID: 36754691
    [TBL] [Abstract][Full Text] [Related]  

  • 71. TAVI for Failed Valve-Sparing Operations: In-Hospital and Mid-Term Outcome.
    Notaristefano F; Notaristefano S; Sclafani R; Reccia MR; Annunziata R; Da Col U; Ambrosio G; Cavallini C
    J Heart Valve Dis; 2017 May; 26(3):268-273. PubMed ID: 29092110
    [TBL] [Abstract][Full Text] [Related]  

  • 72. Transcatheter Aortic Valve Replacement of Failed Surgically Implanted Bioprostheses: The STS/ACC Registry.
    Tuzcu EM; Kapadia SR; Vemulapalli S; Carroll JD; Holmes DR; Mack MJ; Thourani VH; Grover FL; Brennan JM; Suri RM; Dai D; Svensson LG
    J Am Coll Cardiol; 2018 Jul; 72(4):370-382. PubMed ID: 30025572
    [TBL] [Abstract][Full Text] [Related]  

  • 73. Bioprosthetic valve fracture: Technical insights from a multicenter study.
    Allen KB; Chhatriwalla AK; Saxon JT; Cohen DJ; Nguyen TC; Webb J; Loyalka P; Bavry AA; Rovin JD; Whisenant B; Dvir D; Kennedy KF; Thourani V; Lee R;
    J Thorac Cardiovasc Surg; 2019 Nov; 158(5):1317-1328.e1. PubMed ID: 30857820
    [TBL] [Abstract][Full Text] [Related]  

  • 74. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves.
    Dvir D; Webb JG; Bleiziffer S; Pasic M; Waksman R; Kodali S; Barbanti M; Latib A; Schaefer U; Rodés-Cabau J; Treede H; Piazza N; Hildick-Smith D; Himbert D; Walther T; Hengstenberg C; Nissen H; Bekeredjian R; Presbitero P; Ferrari E; Segev A; de Weger A; Windecker S; Moat NE; Napodano M; Wilbring M; Cerillo AG; Brecker S; Tchetche D; Lefèvre T; De Marco F; Fiorina C; Petronio AS; Teles RC; Testa L; Laborde JC; Leon MB; Kornowski R;
    JAMA; 2014 Jul; 312(2):162-70. PubMed ID: 25005653
    [TBL] [Abstract][Full Text] [Related]  

  • 75. Early and Midterm Clinical Outcomes of Transcatheter Valve-in-Valve Implantation Versus Redo Surgical Aortic Valve Replacement for Aortic Bioprosthetic Valve Degeneration: Two Faces of the Same Medal.
    Dokollari A; Cameli M; Mandoli GE; Kalra DS; Poston R; Coku L; Pernoci M; Miri M; Bonacchi M; Gelsomino S
    J Cardiothorac Vasc Anesth; 2021 Nov; 35(11):3223-3231. PubMed ID: 34175205
    [TBL] [Abstract][Full Text] [Related]  

  • 76. Outcomes of valve-in-valve transcatheter aortic valve implantation with and without bioprosthetic valve fracture.
    Brinkmann C; Abdel-Wahab M; Bedogni F; Bhadra OD; Charbonnier G; Conradi L; Hildick-Smith D; Kargoli F; Latib A; Van Mieghem NM; Mylotte D; Landes U; Pilgrim T; Stripling J; Taramasso M; Tchétché D; Testa L; Thiele H; Webb J; Windecker S; Witt J; Wohlmuth P; Schofer J
    EuroIntervention; 2021 Nov; 17(10):848-855. PubMed ID: 34031022
    [TBL] [Abstract][Full Text] [Related]  

  • 77. Femoral transcatheter valve-in-valve implantation as alternative strategy for failed aortic bioprostheses: A single-centre experience with long-term follow-up.
    Stankowski T; Aboul-Hassan SS; Seifi Zinab F; Herwig V; Stępiński P; Grimmig O; Just S; Harnath A; Muehle A; Fritzsche D; Perek B
    Int J Cardiol; 2020 May; 306():25-34. PubMed ID: 32087937
    [TBL] [Abstract][Full Text] [Related]  

  • 78. The aortic Elan stentless aortic valve: excellent hemodynamics and ease of implantation.
    Flynn M; Iaccovoni A; Pathi V; Butler J; Macarthur KJ; Berg GA
    Semin Thorac Cardiovasc Surg; 2001 Oct; 13(4 Suppl 1):48-54. PubMed ID: 11805949
    [TBL] [Abstract][Full Text] [Related]  

  • 79. Transcatheter valve-in-valve implantation with the Edwards SAPIEN in patients with bioprosthetic heart valve failure: the Milan experience.
    Latib A; Ielasi A; Montorfano M; Maisano F; Chieffo A; Cioni M; Mussardo M; Bertoldi L; Shannon J; Sacco F; Covello RD; Figini F; Godino C; Grimaldi A; Spagnolo P; Alfieri O; Colombo A
    EuroIntervention; 2012 Mar; 7(11):1275-84. PubMed ID: 22278193
    [TBL] [Abstract][Full Text] [Related]  

  • 80. Transcatheter aortic valve implantation in pure aortic regurgitation: Hemodynamic and echocardiographic findings in bioprosthesis vs. native valve.
    Paraggio L; Burzotta F; Graziani F; Aurigemma C; Romagnoli E; Pedicino D; Locorotondo G; Mencarelli E; Lillo R; Bruno P; Laezza D; Giambusso N; Lombardo A; Trani C
    Catheter Cardiovasc Interv; 2022 Apr; 99(5):1599-1608. PubMed ID: 35043541
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 64.