BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 28068805)

  • 1. Impact of light exposure on thyroid-stimulating hormone results using the Siemens Advia Centaur TSH-3Ultra assay.
    Armer J; Giles D; Lancaster I; Brownbill K
    Ann Clin Biochem; 2017 Sep; 54(5):612-615. PubMed ID: 28068805
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Establishment of reference intervals for thyroid- stimulating hormone and free thyroxine in amniotic fluid using the Bayer ADVIA Centaur.
    Baumann NA; Gronowski AM
    Am J Clin Pathol; 2007 Jul; 128(1):158-63. PubMed ID: 17580284
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of the ADVIA Centaur TSH-3 assay.
    Vogeser M; Weigand M; Fraunberger P; Fischer H; Cremer P
    Clin Chem Lab Med; 2000 Apr; 38(4):331-4. PubMed ID: 10928654
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Heterophilic antibody interference with TSH measurement on different immunoassay platforms.
    Cheng X; Guo X; Chai X; Hu Y; Lian X; Zhang G
    Clin Chim Acta; 2021 Jan; 512():63-65. PubMed ID: 33285118
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Should functional sensitivity of a new thyroid stimulating hormone immunoassay be monitored routinely? The ADVIA Centaur TSH3-UL assay experience.
    Reix N; Massart C; Gasser F; Heurtault B; Agin A
    Clin Biochem; 2012 Oct; 45(15):1260-2. PubMed ID: 22561000
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Functional sensitivity of seven automated thyroid stimulating hormone immunoassays.
    Owen WE; Gantzer ML; Lyons JM; Rockwood AL; Roberts WL
    Clin Chim Acta; 2011 Nov; 412(23-24):2336-9. PubMed ID: 21851813
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Development of a sensitive, rapid, biotin-streptavidin based chemiluminescent enzyme immunoassay for human thyroid stimulating hormone.
    Lin Z; Wang X; Li ZJ; Ren SQ; Chen GN; Ying XT; Lin JM
    Talanta; 2008 May; 75(4):965-72. PubMed ID: 18585170
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Continuous age-dependent reference ranges for thyroid hormones in neonates, infants, children and adolescents established using the ADVIA Centaur Analyzer.
    Hübner U; Englisch C; Werkmann H; Butz H; Georgs T; Zabransky S; Herrmann W
    Clin Chem Lab Med; 2002 Oct; 40(10):1040-7. PubMed ID: 12476946
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An innovative sample-to-answer polymer lab-on-a-chip with on-chip reservoirs for the POCT of thyroid stimulating hormone (TSH).
    Jung W; Han J; Kai J; Lim JY; Sul D; Ahn CH
    Lab Chip; 2013 Dec; 13(23):4653-62. PubMed ID: 24121997
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Affinity assisted selection of antibodies for Point of Care TSH immunoassay with limited wash.
    Wang D; Skinner JP; Ruan Q; Tetin SY; Collier GB
    Clin Chim Acta; 2015 Jan; 438():55-61. PubMed ID: 25109443
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Thyroid-stimulating hormone and free thyroxine on the ADVIA Centaur immunoassay system: a multicenter assessment of analytical performance.
    Reix N; Massart C; d'Herbomez M; Gasser F; Heurtault B; Agin A
    Clin Biochem; 2013 Sep; 46(13-14):1305-8. PubMed ID: 23628596
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Harmonization protocols for TSH immunoassays: a multicenter study in Italy.
    Clerico A; Ripoli A; Fortunato A; Alfano A; Carrozza C; Correale M; Dittadi R; Gessoni G; Migliardi M; Rizzardi S; Prontera C; Masotti S; Zucchelli G; Guiotto C; Iacovazzi PA; Iervasi G;
    Clin Chem Lab Med; 2017 Oct; 55(11):1722-1733. PubMed ID: 28245185
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of Bayer Advia Centaur immunoassay results obtained on samples collected in four different Becton Dickinson Vacutainer tubes.
    Morovat A; James TS; Cox SD; Norris SG; Rees MC; Gales MA; Taylor RP
    Ann Clin Biochem; 2006 Nov; 43(Pt 6):481-7. PubMed ID: 17132279
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Performance characteristics of six third-generation assays for thyroid-stimulating hormone.
    Rawlins ML; Roberts WL
    Clin Chem; 2004 Dec; 50(12):2338-44. PubMed ID: 15472032
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Thyroid stimulating hormone values of clinical decisions of hypothyroidism measurement by three different automated immunoassays.
    Mirjanic-Azaric B; Jerin A; Radic Z
    Scand J Clin Lab Invest; 2020; 80(2):151-155. PubMed ID: 31841041
    [No Abstract]   [Full Text] [Related]  

  • 16. Use of high-capacity surface with oriented recombinant antibody fragments in a 5-min immunoassay for thyroid-stimulating hormone.
    Brockmann EC; Vehniäinen M; Pettersson K
    Anal Biochem; 2010 Jan; 396(2):242-9. PubMed ID: 19818328
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A mathematical algorithm to harmonize measurements for thyroid-stimulating hormone between instruments.
    Zhou X; Liu Z; Ma Y; Zhang C; Wu Y
    Clin Chim Acta; 2023 Aug; 548():117513. PubMed ID: 37562523
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Enzyme-free chemiluminescence immunoassay for the determination of thyroid stimulating hormone.
    Shim C; Chong R; Lee JH
    Talanta; 2017 Aug; 171():229-235. PubMed ID: 28551133
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Thyroxin overdose due to rheumatoid factor interferences in thyroid-stimulating hormone assays.
    Georges A; Charrié A; Raynaud S; Lombard C; Corcuff JB
    Clin Chem Lab Med; 2011 May; 49(5):873-5. PubMed ID: 21303295
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Interference of anti-streptavidin antibodies: More common than we thought? In relation to six confirmed cases.
    Ricci V; Esteban MP; Sand G; Menises MM
    Clin Biochem; 2021 Apr; 90():62-65. PubMed ID: 33545112
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.