These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
193 related articles for article (PubMed ID: 28070611)
1. Dual mobility cups provide biomechanical advantages in situations at risk for dislocation: a finite element analysis. Terrier A; Latypova A; Guillemin M; Parvex V; Guyen O Int Orthop; 2017 Mar; 41(3):551-556. PubMed ID: 28070611 [TBL] [Abstract][Full Text] [Related]
2. Intra-prosthetic dislocation of dual-mobility cups after total hip arthroplasty: potential causes from a clinical and biomechanical perspective. Fabry C; Langlois J; Hamadouche M; Bader R Int Orthop; 2016 May; 40(5):901-6. PubMed ID: 26429197 [TBL] [Abstract][Full Text] [Related]
3. Prevention of dislocation in total hip revision surgery using a dual mobility design. Philippot R; Adam P; Reckhaus M; Delangle F; Verdot F-; Curvale G; Farizon F Orthop Traumatol Surg Res; 2009 Oct; 95(6):407-13. PubMed ID: 19656750 [TBL] [Abstract][Full Text] [Related]
5. Total hip arthroplasty instability treatment without dual mobility cups: brief overview and experience of other options. Zagra L; Caboni E Int Orthop; 2017 Mar; 41(3):661-668. PubMed ID: 28091768 [TBL] [Abstract][Full Text] [Related]
6. Dual-mobility or Constrained Liners Are More Effective Than Preoperative Bariatric Surgery in Prevention of THA Dislocation. Hernigou P; Trousselier M; Roubineau F; Bouthors C; Flouzat Lachaniette CH Clin Orthop Relat Res; 2016 Oct; 474(10):2202-10. PubMed ID: 27130648 [TBL] [Abstract][Full Text] [Related]
7. All dual mobility cups are not the same. Aslanian T Int Orthop; 2017 Mar; 41(3):573-581. PubMed ID: 28097387 [TBL] [Abstract][Full Text] [Related]
8. Total hip arthroplasty revision by dual-mobility acetabular cup cemented in a metal reinforcement: A 62 case series at a minimum 5 years' follow-up. Lebeau N; Bayle M; Belhaouane R; Chelli M; Havet E; Brunschweiler B; Mertl P Orthop Traumatol Surg Res; 2017 Sep; 103(5):679-684. PubMed ID: 28578096 [TBL] [Abstract][Full Text] [Related]
9. LUMiC Bus MP; Szafranski A; Sellevold S; Goryn T; Jutte PC; Bramer JA; Fiocco M; Streitbürger A; Kotrych D; van de Sande MA; Dijkstra PD Clin Orthop Relat Res; 2017 Mar; 475(3):686-695. PubMed ID: 27020434 [TBL] [Abstract][Full Text] [Related]
10. Dual-mobility arthroplasty failure: a rationale review of causes and technical considerations for revision. Hernigou P; Dubory A; Potage D; Roubineau F; Flouzat Lachaniette CH Int Orthop; 2017 Mar; 41(3):481-490. PubMed ID: 27872981 [TBL] [Abstract][Full Text] [Related]
11. Biomechanical concept and clinical outcome of dual mobility cups. Grazioli A; Ek ET; Rüdiger HA Int Orthop; 2012 Dec; 36(12):2411-8. PubMed ID: 23073926 [TBL] [Abstract][Full Text] [Related]
12. Dual mobility cups in revision total hip arthroplasty. Viste A; Desmarchelier R; Fessy MH Int Orthop; 2017 Mar; 41(3):535-542. PubMed ID: 27933422 [TBL] [Abstract][Full Text] [Related]
13. Low friction arthroplasty and dual mobility cup: a new gold standard. Prudhon JL; Verdier R; Caton JH Int Orthop; 2017 Mar; 41(3):563-571. PubMed ID: 27999924 [TBL] [Abstract][Full Text] [Related]
14. Five to thirteen year results of a cemented dual mobility socket to treat recurrent dislocation. Hamadouche M; Ropars M; Rodaix C; Musset T; Gaucher F; Biau D; Courpied JP; Huten D Int Orthop; 2017 Mar; 41(3):513-519. PubMed ID: 27889840 [TBL] [Abstract][Full Text] [Related]
15. Dual mobility in total hip arthroplasty. Plummer DR; Haughom BD; Della Valle CJ Orthop Clin North Am; 2014 Jan; 45(1):1-8. PubMed ID: 24267202 [TBL] [Abstract][Full Text] [Related]
16. Does dual-mobility cup geometry affect posterior horizontal dislocation distance? Heffernan C; Banerjee S; Nevelos J; Macintyre J; Issa K; Markel DC; Mont MA Clin Orthop Relat Res; 2014 May; 472(5):1535-44. PubMed ID: 24464508 [TBL] [Abstract][Full Text] [Related]
17. Equivalent wear performance of dual mobility bearing compared with standard bearing in total hip arthroplasty: in vitro study. Gaudin G; Ferreira A; Gaillard R; Prudhon JL; Caton JH; Lustig S Int Orthop; 2017 Mar; 41(3):521-527. PubMed ID: 27878334 [TBL] [Abstract][Full Text] [Related]
18. Can Dual Mobility Cups prevent Dislocation in All Situations After Revision Total Hip Arthroplasty? Wegrzyn J; Tebaa E; Jacquel A; Carret JP; Béjui-Hugues J; Pibarot V J Arthroplasty; 2015 Apr; 30(4):631-40. PubMed ID: 25443363 [TBL] [Abstract][Full Text] [Related]
19. Treatment of recurrent THR dislocation using of a cementless dual-mobility cup: a 59 cases series with a mean 8 years' follow-up. Leiber-Wackenheim F; Brunschweiler B; Ehlinger M; Gabrion A; Mertl P Orthop Traumatol Surg Res; 2011 Feb; 97(1):8-13. PubMed ID: 21273156 [TBL] [Abstract][Full Text] [Related]
20. Dual Mobility Acetabular Cups in Primary Total Hip Arthroplasty in Patients at High Risk for Dislocation. Harwin SF; Mistry JB; Chughtai M; Khlopas A; Gwam C; Newman JM; Higuera CA; Bonutti PM; Malkani AL; Kolisek FR; Delanois RE; Mont MA Surg Technol Int; 2017 Jul; 30():251-258. PubMed ID: 28395391 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]