These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

162 related articles for article (PubMed ID: 28070629)

  • 81. Stainless steel or titanium mini-implants?
    Mecenas P; Espinosa DG; Cardoso PC; Normando D
    Angle Orthod; 2020 Jul; 90(4):587-597. PubMed ID: 33378494
    [TBL] [Abstract][Full Text] [Related]  

  • 82. Functionalized orthopaedic implant as pH electrochemical sensing tool for smart diagnosis of hardware infection.
    Fiore L; Mazzaracchio V; Gosti C; Duranti L; Vitiello R; Maccauro G; Arduini F
    Analyst; 2024 May; 149(11):3085-3096. PubMed ID: 38712737
    [TBL] [Abstract][Full Text] [Related]  

  • 83. Host Immune Regulation in Implant-Associated Infection (IAI): What Does the Current Evidence Provide Us to Prevent or Treat IAI?
    Maimaiti Z; Li Z; Xu C; Fu J; Hao LB; Chen JY; Chai W
    Bioengineering (Basel); 2023 Mar; 10(3):. PubMed ID: 36978747
    [TBL] [Abstract][Full Text] [Related]  

  • 84. Implant removal of osteosynthesis: the Dutch practice. Results of a survey.
    Vos D; Hanson B; Verhofstad M
    J Trauma Manag Outcomes; 2012 Aug; 6(1):6. PubMed ID: 22863279
    [TBL] [Abstract][Full Text] [Related]  

  • 85. Indications for implant removal after fracture healing: a review of the literature.
    Vos DI; Verhofstad MH
    Eur J Trauma Emerg Surg; 2013 Aug; 39(4):327-37. PubMed ID: 26815392
    [TBL] [Abstract][Full Text] [Related]  

  • 86. Bioactive coating provides antimicrobial protection through immunomodulation and phage therapeutics.
    Wu KZ; Le Z; Myint B; Chan B; Liu L; Huang H; Sing SL; Tay A
    Mater Today Bio; 2024 Jun; 26():101022. PubMed ID: 38525309
    [TBL] [Abstract][Full Text] [Related]  

  • 87. The impact of metal implants on the dose and clinical outcome of radiotherapy (Review).
    Liang Y; Xu H; Tang W; Du X
    Mol Clin Oncol; 2024 Oct; 21(4):66. PubMed ID: 39091418
    [TBL] [Abstract][Full Text] [Related]  

  • 88. Comparison of spring characteristics of titanium-molybdenum alloy and stainless steel.
    Sheibaninia A; Salehi A; Asatourian A
    J Clin Exp Dent; 2018 Jun; 10(6):e628. PubMed ID: 29930784
    [TBL] [Abstract][Full Text] [Related]  

  • 89. Diagnosis of orthopaedic-implant-associated infections caused by slow-growing Gram-positive anaerobic bacteria - a clinical perspective.
    Ponraj DS; Falstie-Jensen T; Jørgensen NP; Ravn C; Brüggemann H; Lange J
    J Bone Jt Infect; 2021; 6(8):367-378. PubMed ID: 34660180
    [TBL] [Abstract][Full Text] [Related]  

  • 90. [Experimental studies on titanium as a material for fracture treatment].
    OHBA S
    Nihon Seikeigeka Gakkai Zasshi; 1962 Apr; 36():23-40. PubMed ID: 14481358
    [No Abstract]   [Full Text] [Related]  

  • 91. Statistics in Infection and immunity revisited.
    Olsen CH
    Infect Immun; 2014 Mar; 82(3):916-20. PubMed ID: 24343646
    [TBL] [Abstract][Full Text] [Related]  

  • 92. [Implant-associated infections in trauma surgery].
    Alt V
    Unfallchirurgie (Heidelb); 2024 Feb; 127(2):87-88. PubMed ID: 38300255
    [No Abstract]   [Full Text] [Related]  

  • 93. Locking Cap Designs Improve Fatigue Properties of Polyaxial Screws in Upper Extremity Applications.
    Namdari S; Mehta S; Tierney A; Hast MW
    J Orthop Trauma; 2017 May; 31(5):275-280. PubMed ID: 28072648
    [TBL] [Abstract][Full Text] [Related]  

  • 94. Biofilm and its implications postfracture fixation: All I need to know.
    Kanakaris NK; Giannoudis PV
    OTA Int; 2021 Jun; 4(3 Suppl):. PubMed ID: 37609478
    [TBL] [Abstract][Full Text] [Related]  

  • 95. [Susceptibility to infections and behavior of stainless steel : Comparison with titanium implants in traumatology].
    Haubruck P; Schmidmaier G
    Unfallchirurg; 2017 Feb; 120(2):110-115. PubMed ID: 28070629
    [TBL] [Abstract][Full Text] [Related]  

  • 96. [Titanium or steel as osteosynthesis material : Systematic literature search for clinical evidence].
    Joeris A; Goldhahn S; Rometsch E; Höntzsch D
    Unfallchirurg; 2017 Feb; 120(2):96-102. PubMed ID: 28108750
    [TBL] [Abstract][Full Text] [Related]  

  • 97. [Compatibility and allergies of osteosynthesis materials].
    Thomsen M; Thomas P
    Unfallchirurg; 2017 Feb; 120(2):116-121. PubMed ID: 28108751
    [TBL] [Abstract][Full Text] [Related]  

  • 98. Evidence-based uncertainty: do implant-related properties of titanium reduce the susceptibility to perioperative infections in clinical fracture management? A systematic review.
    Tanner MC; Fischer C; Schmidmaier G; Haubruck P
    Infection; 2021 Oct; 49(5):813-821. PubMed ID: 33586124
    [TBL] [Abstract][Full Text] [Related]  

  • 99.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 100.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.