688 related articles for article (PubMed ID: 28072394)
1. Three-dimensional cascaded system analysis of a 50 µm pixel pitch wafer-scale CMOS active pixel sensor x-ray detector for digital breast tomosynthesis.
Zhao C; Vassiljev N; Konstantinidis AC; Speller RD; Kanicki J
Phys Med Biol; 2017 Mar; 62(5):1994-2017. PubMed ID: 28072394
[TBL] [Abstract][Full Text] [Related]
2. 50 μm pixel pitch wafer-scale CMOS active pixel sensor x-ray detector for digital breast tomosynthesis.
Zhao C; Konstantinidis AC; Zheng Y; Anaxagoras T; Speller RD; Kanicki J
Phys Med Biol; 2015 Dec; 60(23):8977-9001. PubMed ID: 26540090
[TBL] [Abstract][Full Text] [Related]
3. Amorphous In-Ga-Zn-O thin-film transistor active pixel sensor x-ray imager for digital breast tomosynthesis.
Zhao C; Kanicki J
Med Phys; 2014 Sep; 41(9):091902. PubMed ID: 25186389
[TBL] [Abstract][Full Text] [Related]
4. Cascaded systems analysis of a-Se/a-Si and a-InGaZnO TFT passive and active pixel sensors for tomosynthesis.
Sengupta A; Zhao C; Konstantinidis A; Kanicki J
Phys Med Biol; 2019 Jan; 64(2):025012. PubMed ID: 30523916
[TBL] [Abstract][Full Text] [Related]
5. Large area CMOS active pixel sensor x-ray imager for digital breast tomosynthesis: Analysis, modeling, and characterization.
Zhao C; Kanicki J; Konstantinidis AC; Patel T
Med Phys; 2015 Nov; 42(11):6294-308. PubMed ID: 26520722
[TBL] [Abstract][Full Text] [Related]
6. Modeling and evaluation of a high-resolution CMOS detector for cone-beam CT of the extremities.
Cao Q; Sisniega A; Brehler M; Stayman JW; Yorkston J; Siewerdsen JH; Zbijewski W
Med Phys; 2018 Jan; 45(1):114-130. PubMed ID: 29095489
[TBL] [Abstract][Full Text] [Related]
7. The effect of amorphous selenium detector thickness on dual-energy digital breast imaging.
Hu YH; Zhao W
Med Phys; 2014 Nov; 41(11):111904. PubMed ID: 25370637
[TBL] [Abstract][Full Text] [Related]
8. Cascaded systems analysis of shift-variant image quality in slit-scanning breast tomosynthesis.
Berggren K; Cederström B; Lundqvist M; Fredenberg E
Med Phys; 2018 Oct; 45(10):4392-4401. PubMed ID: 30091470
[TBL] [Abstract][Full Text] [Related]
9. Experimental validation of a three-dimensional linear system model for breast tomosynthesis.
Zhao B; Zhou J; Hu YH; Mertelmeier T; Ludwig J; Zhao W
Med Phys; 2009 Jan; 36(1):240-51. PubMed ID: 19235392
[TBL] [Abstract][Full Text] [Related]
10. Three-dimensional linear system analysis for breast tomosynthesis.
Zhao B; Zhao W
Med Phys; 2008 Dec; 35(12):5219-32. PubMed ID: 19175081
[TBL] [Abstract][Full Text] [Related]
11. Physical characterization and performance comparison of active- and passive-pixel CMOS detectors for mammography.
Elbakri IA; McIntosh BJ; Rickey DW
Phys Med Biol; 2009 Mar; 54(6):1743-55. PubMed ID: 19242050
[TBL] [Abstract][Full Text] [Related]
12. Technical assessment of 2D and 3D imaging performance of an IGZO-based flat-panel X-ray detector.
Sheth NM; Uneri A; Helm PA; Zbijewski W; Siewerdsen JH
Med Phys; 2022 May; 49(5):3053-3066. PubMed ID: 35363391
[TBL] [Abstract][Full Text] [Related]
13. Mobile C-Arm with a CMOS detector: Technical assessment of fluoroscopy and Cone-Beam CT imaging performance.
Sheth NM; Zbijewski W; Jacobson MW; Abiola G; Kleinszig G; Vogt S; Soellradl S; Bialkowski J; Anderson WS; Weiss CR; Osgood GM; Siewerdsen JH
Med Phys; 2018 Dec; 45(12):5420-5436. PubMed ID: 30339271
[TBL] [Abstract][Full Text] [Related]
14. Empirical electro-optical and x-ray performance evaluation of CMOS active pixels sensor for low dose, high resolution x-ray medical imaging.
Arvanitis CD; Bohndiek SE; Royle G; Blue A; Liang HX; Clark A; Prydderch M; Turchetta R; Speller R
Med Phys; 2007 Dec; 34(12):4612-25. PubMed ID: 18196789
[TBL] [Abstract][Full Text] [Related]
15. Nonstationary model of oblique x-ray incidence in amorphous selenium detectors: II. Transfer functions.
Acciavatti RJ; Maidment ADA
Med Phys; 2019 Feb; 46(2):505-516. PubMed ID: 30488455
[TBL] [Abstract][Full Text] [Related]
16. Optimization of phosphor-based detector design for oblique x-ray incidence in digital breast tomosynthesis.
Acciavatti RJ; Maidment AD
Med Phys; 2011 Nov; 38(11):6188. PubMed ID: 22047384
[TBL] [Abstract][Full Text] [Related]
17. Digital radiology using active matrix readout of amorphous selenium: theoretical analysis of detective quantum efficiency.
Zhao W; Rowlands JA
Med Phys; 1997 Dec; 24(12):1819-33. PubMed ID: 9434965
[TBL] [Abstract][Full Text] [Related]
18. MTF and DQE enhancement using an apodized-aperture x-ray detector design.
Nano TF; Escartin T; Ismailova E; Karim KS; Lindström J; Kim HK; Cunningham IA
Med Phys; 2017 Sep; 44(9):4525-4535. PubMed ID: 28636792
[TBL] [Abstract][Full Text] [Related]
19. Task-Based Modeling of a 5k Ultra-High-Resolution Medical Imaging System for Digital Breast Tomosynthesis.
Zhao C; Kanicki J
IEEE Trans Med Imaging; 2017 Sep; 36(9):1820-1831. PubMed ID: 28436856
[TBL] [Abstract][Full Text] [Related]
20. Performance of a novel wafer scale CMOS active pixel sensor for bio-medical imaging.
Esposito M; Anaxagoras T; Konstantinidis AC; Zheng Y; Speller RD; Evans PM; Allinson NM; Wells K
Phys Med Biol; 2014 Jul; 59(13):3533-54. PubMed ID: 24909098
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]