These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 28076302)

  • 1. Detecting paraprotein interference on a direct bilirubin assay by reviewing the photometric reaction data.
    García-González E; Aramendía M; González-Tarancón R; Romero-Sánchez N; Rello L
    Clin Chem Lab Med; 2017 Jul; 55(8):1178-1185. PubMed ID: 28076302
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Analytical interference by monoclonal immunoglobulins on the direct bilirubin AU Beckman Coulter assay: the benefit of unsuspected diagnosis from spurious results.
    García-González E; González-Tarancón R; Aramendía M; Rello L
    Clin Chem Lab Med; 2016 Aug; 54(8):1329-35. PubMed ID: 26677886
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Paraproteins are a common cause of interferences with automated chemistry methods.
    Yang Y; Howanitz PJ; Howanitz JH; Gorfajn H; Wong K
    Arch Pathol Lab Med; 2008 Feb; 132(2):217-23. PubMed ID: 18251580
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Monoclonal and polyclonal immunoglobulin interference in a conjugated bilirubin assay.
    Song L; Kelly KA; Butch AW
    Arch Pathol Lab Med; 2014 Jul; 138(7):950-4. PubMed ID: 24978922
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Artifactual hyperbilirubinemia due to paraprotein interference.
    Pantanowitz L; Horowitz GL; Upalakalin JN; Beckwith BA
    Arch Pathol Lab Med; 2003 Jan; 127(1):55-9. PubMed ID: 12521367
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Protein precipitation as a possible important pitfall in the clinical chemistry analysis of blood samples containing monoclonal immunoglobulins: 2 case reports and a review of the literature.
    Berth M; Delanghe J
    Acta Clin Belg; 2004; 59(5):263-73. PubMed ID: 15641396
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The abnormal reaction data-detecting function of the automated biochemical analyzer was useful to prevent erroneous total-bilirubin measurement and to identify monoclonal proteins.
    Seimiya M; Suzuki Y; Yoshida T; Sawabe Y; Matsushita K; Nomura F
    Clin Chim Acta; 2015 Feb; 441():44-6. PubMed ID: 25523191
    [TBL] [Abstract][Full Text] [Related]  

  • 8. How paraproteins can affect laboratory assays: spurious results and biological effects.
    King RI; Florkowski CM
    Pathology; 2010; 42(5):397-401. PubMed ID: 20632813
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Factors influencing naproxen metabolite interference in total bilirubin assays.
    Saifee NH; Ranjitkar P; Greene DN
    Clin Biochem; 2016 Apr; 49(6):514-517. PubMed ID: 26589001
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pseudohypobicarbonatemia caused by an endogenous assay interferent: a new entity.
    Goldwasser P; Manjappa NG; Luhrs CA; Barth RH
    Am J Kidney Dis; 2011 Oct; 58(4):617-20. PubMed ID: 21849226
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Artifactual laboratory abnormalities in patients with paraproteinemia.
    Roy V
    South Med J; 2009 Feb; 102(2):167-70. PubMed ID: 19139717
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Paraprotein interference in an assay of conjugated bilirubin.
    Nauti A; Barassi A; Merlini G; d'Eril GV
    Clin Chem; 2005 Jun; 51(6):1076-7. PubMed ID: 15914800
    [No Abstract]   [Full Text] [Related]  

  • 13. Evaluation of methods to eliminate analytical interference in multiple myeloma patients with spurious hyperphosphatemia.
    Tian X; Zhao L; Ma J; Lu J; Zhu TY; Liu Y; Sun HX
    Lab Med; 2023 Nov; 54(6):598-602. PubMed ID: 36942666
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Paraprotein interference with turbidimetric gentamicin assay.
    Dimeski G; Bassett K; Brown N
    Biochem Med (Zagreb); 2015; 25(1):117-24. PubMed ID: 25672475
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Correction of patient results for Beckman Coulter LX-20 assays affected by interference due to hemoglobin, bilirubin or lipids: a practical approach.
    Vermeer HJ; Steen G; Naus AJ; Goevaerts B; Agricola PT; Schoenmakers CH
    Clin Chem Lab Med; 2007; 45(1):114-9. PubMed ID: 17243928
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Analytical Interference Leading to a Diagnosis of Lymphoproliferative Disorder].
    Kurfürstová I; Šálek T; Kadlčková E; Pšenčík M
    Klin Onkol; 2017; 30(1):55-57. PubMed ID: 28185466
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Diagnostic accuracy of icteric index to detect abnormal total bilirubin values.
    Salinas M; López-Garrigós M; Lugo J; Gutiérrez M; Flors L; Leiva-Salinas C
    J Clin Pathol; 2012 Oct; 65(10):928-33. PubMed ID: 22859392
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Contribution of the laboratory to a diagnosis process by sequential reflective testing: Paraprotein interference on a direct bilirubin assay.
    Yilmaz NS; Sen B; Gulbahar O
    Biochem Med (Zagreb); 2021 Jun; 31(2):020801. PubMed ID: 33927558
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Predictive power of prothrombin time and serum total bilirubin for postoperative mortality after major hepatectomy with extrahepatic bile duct resection.
    Yokoyama Y; Ebata T; Igami T; Sugawara G; Ando M; Nagino M
    Surgery; 2014 Mar; 155(3):504-11. PubMed ID: 24287146
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Paraprotein interference in automated chemistry analyzers.
    Sheppard CA; Allen RC; Austin GE; Young AN; Ribeiro MA; Fantz CR
    Clin Chem; 2005 Jun; 51(6):1077-8. PubMed ID: 15914801
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 8.