BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

269 related articles for article (PubMed ID: 28085867)

  • 1. Combined diffuse optical tomography and photoacoustic tomography for enhanced functional imaging of small animals: a methodological study on phantoms.
    Wang Y; Li J; Lu T; Zhang L; Zhou Z; Zhao H; Gao F
    Appl Opt; 2017 Jan; 56(2):303-311. PubMed ID: 28085867
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Design and evaluation of a hybrid photoacoustic tomography and diffuse optical tomography system for breast cancer detection.
    Xi L; Li X; Yao L; Grobmyer S; Jiang H
    Med Phys; 2012 May; 39(5):2584-94. PubMed ID: 22559629
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Indocyanine green enhanced co-registered diffuse optical tomography and photoacoustic tomography.
    Xu C; Kumavor PD; Alqasemi U; Li H; Xu Y; Zanganeh S; Zhu Q
    J Biomed Opt; 2013 Dec; 18(12):126006. PubMed ID: 24343437
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Tutorial on photoacoustic tomography.
    Zhou Y; Yao J; Wang LV
    J Biomed Opt; 2016 Jun; 21(6):61007. PubMed ID: 27086868
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Integrated photoacoustic and diffuse optical tomography system for imaging of human finger joints in vivo.
    Xi L; Jiang H
    J Biophotonics; 2016 Mar; 9(3):213-7. PubMed ID: 26431473
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quantitative photoacoustic imaging: correcting for heterogeneous light fluence distributions using diffuse optical tomography.
    Bauer AQ; Nothdurft RE; Erpelding TN; Wang LV; Culver JP
    J Biomed Opt; 2011 Sep; 16(9):096016. PubMed ID: 21950930
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Improving vascular imaging with co-planar mutually guided photoacoustic and diffuse optical tomography: a simulation study.
    Mahmoodkalayeh S; Zarei M; Ansari MA; Kratkiewicz K; Ranjbaran M; Manwar R; Avanaki K
    Biomed Opt Express; 2020 Aug; 11(8):4333-4347. PubMed ID: 32923047
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Visual Quality Enhancement in Optoacoustic Tomography Using Active Contour Segmentation Priors.
    Mandal S; Dean-Ben XL; Razansky D
    IEEE Trans Med Imaging; 2016 Oct; 35(10):2209-2217. PubMed ID: 27093547
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of breast tumor margins in vivo with intraoperative photoacoustic imaging.
    Xi L; Grobmyer SR; Wu L; Chen R; Zhou G; Gutwein LG; Sun J; Liao W; Zhou Q; Xie H; Jiang H
    Opt Express; 2012 Apr; 20(8):8726-31. PubMed ID: 22513583
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Diffuse optical tomography for breast cancer imaging guided by computed tomography: A feasibility study.
    Baikejiang R; Zhang W; Li C
    J Xray Sci Technol; 2017; 25(3):341-355. PubMed ID: 27983569
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Target detection and quantification using a hybrid hand-held diffuse optical tomography and photoacoustic tomography system.
    Kumavor PD; Xu C; Aguirre A; Gamelin J; Ardeshirpour Y; Tavakoli B; Zanganeh S; Alqasemi U; Yang Y; Zhu Q
    J Biomed Opt; 2011 Apr; 16(4):046010. PubMed ID: 21529079
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Time-domain fluorescence-guided diffuse optical tomography based on the third-order simplified harmonics approximation.
    Ma W; Zhang W; Yi X; Li J; Wu L; Wang X; Zhang L; Zhou Z; Zhao H; Gao F
    Appl Opt; 2012 Dec; 51(36):8656-68. PubMed ID: 23262607
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Three-dimensional imaging of xenograft tumors using optical computed and emission tomography.
    Oldham M; Sakhalkar H; Oliver T; Wang YM; Kirpatrick J; Cao Y; Badea C; Johnson GA; Dewhirst M
    Med Phys; 2006 Sep; 33(9):3193-202. PubMed ID: 17022212
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Quantitative photoacoustic imaging of two-photon absorption.
    Bardsley P; Ren K; Zhang R
    J Biomed Opt; 2018 Jan; 23(1):1-11. PubMed ID: 29297207
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Combining microscopy with mesoscopy using optical and optoacoustic label-free modes.
    Soliman D; Tserevelakis GJ; Omar M; Ntziachristos V
    Sci Rep; 2015 Aug; 5():12902. PubMed ID: 26306396
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Investigation of a diffuse optical measurements-assisted quantitative photoacoustic tomographic method in reflection geometry.
    Xu C; Kumavor PD; Aguirre A; Zhu Q
    J Biomed Opt; 2012 Jun; 17(6):061213. PubMed ID: 22734743
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Implementation of a phase array diffuse optical tomographic imager.
    Rajan K; Vijayakumar V; Biswas SK; Vasu RM
    Rev Sci Instrum; 2008 Aug; 79(8):084301. PubMed ID: 19044366
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Two schemes for quantitative photoacoustic tomography based on Monte Carlo simulation.
    Liu Y; Jiang H; Yuan Z
    Med Phys; 2016 Jul; 43(7):3987. PubMed ID: 27370117
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Spatial-frequency-compression scheme for diffuse optical tomography with dense sampling dataset.
    Zhou X; Fan Y; Hou Q; Zhao H; Gao F
    Appl Opt; 2013 Mar; 52(9):1779-92. PubMed ID: 23518718
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Combined diffuse optical tomography (DOT) and MRI system for cancer imaging in small animals.
    Gulsen G; Birgul O; Unlu MB; Shafiiha R; Nalcioglu O
    Technol Cancer Res Treat; 2006 Aug; 5(4):351-63. PubMed ID: 16866566
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.